Invacare POC1–115–AZ User manual

Category
Rechargeable batteries
Type
User manual

This manual is also suitable for

Invacare®
Model:POC1–115,POC1–115–AZ,POC1–115–C,
POC1–115–EU
enBatteryCharger
UserManual
ThismanualMUSTbegiventotheuseroftheproduct.
BEFOREusingthisproduct,readthismanualandsaveforfuturereference.
©2016Invacare®Corporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithout
priorwrittenpermissionfromInvacare.Trademarksareidentifiedby™and®.Alltrademarksare
ownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
MakingLife’sExperiencesPossibleisatrademarkintheU.S.A.
Pine-solandLestoilareregisteredtrademarksofTheCloroxCompany.
DawnisaregisteredtrademarkofTheProctorandGambleCompany.
TheseinstructionsarealsoavailableontheInvacarewebsiteatwww.invacare.com.
Contents
1General........................................4
1.1Symbols.....................................4
1.2IntendedUse..................................5
1.3Contraindications..............................5
1.4ComponentIdentification.........................6
2Safety..........................................7
2.1LabelLocations................................7
2.2GeneralGuidelines.............................8
2.3OperatingInformation...........................9
2.4RadioFrequencyInterference......................9
3Setup..........................................10
3.1Unpacking....................................10
3.2Inspection....................................10
3.3SelectingaLocation.............................11
4Usage..........................................12
4.1Introduction..................................12
4.2ChargingYourBattery...........................12
5Maintenance....................................14
5.1Maintenance..................................14
5.2ServiceLife...................................14
5.3CleaningandDisinfectionBetweenPatients............14
5.4PeriodicInspections.............................15
5.5CleaningtheHousing............................15
5.6Storage......................................16
6AfterUse.......................................17
6.1RecyclingInformation............................17
7Troubleshooting.................................18
7.1Troubleshooting...............................18
8Technicaldata...................................19
8.1Specifications..................................19
9Warranty.......................................21
9.1NorthAmericanLimitedWarranty..................21
9.2LimitedWarranty—Europe,AustraliaandNew
Zealand....................................22
Invacare®
1General
1.1Symbols
Signalwordsareusedinthismanualandapplytohazardsorunsafe
practiceswhichcouldresultinpersonalinjuryorpropertydamage.
Seetheinformationbelowfordefinitionsofthesignalwords.
DANGER!
Dangerindicatesanimminentlyhazardoussituation
which,ifnotavoided,willresultindeathorserious
injury.
WARNING!
Warningindicatesapotentiallyhazardoussituation
which,ifnotavoided,couldresultindeathorserious
injury.
CAUTION!
Cautionindicatesapotentiallyhazardoussituation
which,ifnotavoided,mayresultinpropertydamage
orminorinjuryorboth.
Givesusefultips,recommendationsandinformationfor
efficient,trouble-freeuse.
Refertothefollowingtableforthemeaningofsymbolsmarkedon
theequipmentand/orpackaging.
FollowInstructionsforUse
Thecolorofthe
symbolbackgroundis
blueonproductlabels.
Keepdry
IndoorUseOnly
DONOTdisposeofin
householdwaste
Thisproductcomplieswith
applicableEUdirectives
Manufacturer
DateofManufacture
EuropeanCommunity
AuthorizedRepresentative
SerialNumber
4
1187396-A-02
General
Recycle
DirectCurrent
AlternatingCurrent
ClassIIEquipment
1.2IntendedUse
TheInvacare®BatteryCharger,modelPOC1–115,isintendedto
allowthepatientorcaregivertochargeanInvacareBattery,model
POC1–110,independentlyoftheportableoxygenconcentrator.It
isintendedforindooruseonly.
Nospecificproductknowledgeortrainingisrequiredtooperatethis
productotherthanwhatiscontainedinthismanual.
Thisproductisintendedtobeusedbyadultsorunderadult
supervisiononlyafterreadingandunderstandingtheinstructions
andwarningsofthisusermanual.
Batterysoldseparately.
WARNING!
RiskofInjuryorDamage
Useofthisproductoutsideoftheintendeduseand
specificationshasnotbeentestedandmayleadto
productdamage,lossofproductfunction,orpersonal
injury.
DONOTusethisproductinanywayotherthan
describedinthespecificationsandintendeduse
sectionsofthismanual.
1.3Contraindications
Therearenoknowncontraindicationsforthisproduct.
1187396-A-025
Invacare®
1.4ComponentIdentification
A
BatteryChargerBase
B
ACPowerCord
C
ACPowerAdapter
D
PowerInputConnection
E
StatusIndicatorLight
61187396-A-02
Safety
2Safety
2.1LabelLocations
:YYWW
Ma d e in C h in a
Battery Charger
Ou t p u t : 1 6 .8 V 3 A
In p u t 2 0 V 3. 6 A;
;
SN
:YYWW-XXXXX
P /N 11 8 75 2 0;
;
5
1
1 8 7 5 2 0 -A
Model :POC1 11 5)
)
-
Inva ca re C o rp o ra tion
21 0 1 E.La ke Ma ry Blv d .
S an for d , FL 32 77 3 US A
Tel: 4 0 7-32 1 -5 6 3 0
Tec h n ica l S e r vic es
Tel: 4 4 0-32 9 -6 5 9 3
80 0 -8 3 2 - 4 7 0 7
G e rm a ny
1187396-A-027
Invacare®
2.2GeneralGuidelines
WARNING!
IMPORTANTSAFETYINSTRUCTIONS
SAVETHESEINSTRUCTIONS
Thismanualcontainsimportantsafetyandoperating
instructionsforthebatterycharger.
DANGER!
RiskOfDeath,Injury,OrDamage
Improperuseoftheproductmaycausedeath,injuryor
damage.Thissectioncontainsimportantinformationfor
thesafeoperationanduseofthisproduct.
DONOTusethisproductoranyavailableoptional
equipmentwithoutfirstcompletelyreadingand
understandingtheseinstructionsandanyadditional
instructionalmaterialsuchasusermanuals,service
manualsorinstructionsheetssuppliedwiththis
productoroptionalequipment.
Ifyouareunabletounderstandthewarnings,cautions
orinstructions,contactahealthcareprofessional,
dealerortechnicalpersonnelbeforeattemptingto
usethisequipment.
CheckALLexternalcomponentsandcartonfor
damage.Incaseofdamage,oriftheproductisnot
workingcorrectly,contactatechnicianorInvacare
forrepair.
DONOTuseifhousingofbatterychargerorAC
poweradapteriscrackedorseparated.
THEINFORMATIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
WARNING!
RiskOfInjuryOrDamage
Invacareproductsarespecificallydesignedand
manufacturedforuseinconjunctionwithInvacare
providedorspecifiedaccessories.Anyother
accessorieshavenotbeentestedbyInvacareandare
notrecommendedforusewithInvacareproducts.
Nomodificationofthisequipmentisallowed.
DANGER!
RiskofDeath,Injury,fromElectricShock
Toreducetheriskofburns,electrocution,deathor
injurytopersons:
DONOTdisassemble.Referservicingtoqualified
servicepersonnel.Therearenouserserviceable
parts.
DONOTcomeincontactwiththebatterycharger
whilewet.
DONOTplaceorstorethebatterychargerwhereit
candropintowaterorotherliquid.
DONOTreachforbatterychargerthathasfallen
intowater.UnplugIMMEDIATELY.
DONOTusefrayedordamagedpowercords.
DONOTuseACpoweradapterifitshousingis
crackedorseparated.
Callaqualifiedtechnicianforexaminationandrepair
ifthepowersupplyhasadamagedcordorplug,ifit
isnotworkingproperly,ifithasbeendroppedor
damaged,orifithasbeendroppedintowater.
81187396-A-02
Safety
CAUTION!
RiskofInjuryorDamage
Toavoidinjuryordamagewhichwillvoidwarranty:
ChargeonlyInvacaremodelPOC1–110batteries.
Useonlytheprovidedpowersupply.
Keepelectricalcontactsfreefromdebris.
WARNING!
RiskofInjuryorDeath
Thebatterychargerisintendedforusebyadultsonly.
Closesupervisionisnecessarywhenthebattery
chargerisusednearchildrenorpersonswithreduced
physical,sensoryormentalcapabilitiesorlackof
experienceandknowledge.
Childrenshouldnotplaywiththebatterycharger.
Properlystoreandpositionelectricalcordstoprevent
trippingandstrangulationhazards.
2.3OperatingInformation
TheInvacarebatterychargerwillallowchargingtheInvacarebattery,
modelPOC1–110,independentlyoftheconcentrator.
ThebatterychargerispoweredbytheACpoweradaptercontained
inthebatterychargerkit.Thebatterychargermustonlybesupplied
atthevoltagecorrespondingtothemarkingontheappliance.
ThemodelPOC1–110batterywillobtainacompletechargewithin
fourhoursafterbeingproperlyconnectedtothebatterycharger.
Batterysoldseparately.
2.4RadioFrequencyInterference
MedicalElectricalEquipmentneedstobeinstalledandusedaccording
totheEMCinformationinthismanual.
ThisequipmenthasbeentestedandfoundtocomplywithEMClimits
specifiedbyIEC/EN60601–1–2.Theselimitsaredesignedtoprovide
areasonableprotectionagainstelectromagneticinterferenceina
typicalhomehealthcareenvironment.
PortableandmobileRFcommunicationsequipmentcanaffectthe
operationofthisequipment.Useofthisequipmentadjacentto
orstackedwithotherequipmentshouldbeavoidedasitcould
resultinimproperoperation.Thebatterychargeroperationshould
beobservedtoverifynormaloperationinthepresenceofsuch
equipment.
Otherdevicesmayexperienceinterferencefromeventhelowlevels
ofelectromagneticemissionspermittedbytheabovestandards.To
determineiftheemissionsfromthebatterychargeriscausingthe
interference,turntheunitoff.Iftheinterferencewiththeother
device(s)stops,thentheunitiscausingtheinterference.Insuch
rarecases,interferencemaybereducedorcorrectedbyoneofthe
followingmeasures:
Reposition,relocate,orincreasetheseparationbetweenthe
equipment.
Connecttheequipmentintoanoutletonacircuitdifferentfrom
thattowhichtheotherdevice(s)isconnected.
RefertothePlatinumMobileOxygenConcentratorusermanualfor
additionalinformationonEMC.
1187396-A-029
Invacare®
3Setup
3.1Unpacking
1.Checkforanyobviousdamagetothecartonoritscontents.If
damageisevident,notifythecarrier,oryourlocaldealer.
2.Removeallloosepackingfromthecarton.
3.Carefullyremoveallthecomponentsfromthecarton.
UnlessthebatterychargeristobeusedIMMEDIATELY,
leaveitinitspackagingforstorage.
4.ThebatterychargerkitcontainsthisUserManualandthe
followingitems.Ifanyitemsaremissingpleasecontactyour
provider.
BatteryChargerBase(P/N1187520)
ACPowerAdapter(P/N1187530)
ACpowercord(PartNumber1187454formodel
POC1–115,PartNumber1160792formodel
POC1–115-AZ,PartNumber1152805and1160791for
modelPOC1–115-EU)
3.2Inspection
Inspect/examineexteriorofthebatterychargerandACpower
adapterforcracks,scratchesorotherdamage.Ifanyitemsare
damagedpleasecontactyourprovider.
ContactInvacareoryourhealthcareproviderforassistance
withthesetupprocedureortoreportunexpectedoperation
orevents.
101187396-A-02
Setup
3.3SelectingaLocation
WARNING!
RiskofElectricalShock
IndooruseONLY.Donotexposetorain.
CAUTION!
RiskofDamage
Thebatterychargerwillperformbestwhenoperated
undertheconditionsoutlinedinSpecifications.
Useofthebatterychargerinenvironmentsotherthan
thosedescribedmayresultintheneedforincreased
equipmentmaintenance.
1.Selectatable,shelforotherstablesurfacethatisflatanddry
andthatwillallowforgoodaircirculationaroundthebattery
andbatterycharger.
2.Keepclutterawayfrombatterycharger.
3.Keepthebatteryandbatterychargerfreefromdirt,lintand
debris.
1187396-A-02
11
Invacare®
4Usage
4.1Introduction
TheInvacarebatterycharger,modelPOC1–115,isintendedtoallow
thepatientorcaregivertochargeanInvacaremodelPOC1–110
batteryindependentlyoftheportableoxygenconcentrator.
TheInvacarebatterychargerincorporatesamulticoloredLED
indicatortoshowchargingstatusandanautomaticshutoffto
preventovercharging.
Yourprovidershouldbecontactedwithanyquestionsorproblems
regardingyourbatterycharger.Thisusermanualwilltellyouabout
yourbatterychargerandwillserveasareferenceasyouuseyour
batterycharger.
4.2ChargingYourBattery
1.PlugtheACpowercordconnectorintotheACpoweradapter.
2.PlugtheACpowercordintoawalloutlet.
3.PlugtheoutletconnectoroftheACpoweradapterintothe
inputconnectorofthechargerbase.
12
1187396-A-02
Usage
4.AlignthebatterysothattheInvacarelogoisfacingyou.Gently
placethebatteryintothechargerbaseasshown.Whenthe
batterycontactsareengaged,thestatusindicatorlightwillbegin
flashinggreen,indicatingthebatteryisbeingcharged.
Theindicatorlightisoffwhenabatterypackisnot
installedinthechargerbase.
Chargerbaseslotiskeyedsothatthebatterypack
cannotbeinsertedbackwards.
IndicatorLight
ChargingStatus
FlashinggreenlightBatteryischarging
Yellowlight
(constanton)
Faultcondition,referto
Troubleshooting.
Greenlight
(constanton)
Batteryisfullycharged
5.Whenthebatterypackisfullycharged,thestatusindicatorlight
willbeconstantgreen.
6.Removethebatterypackwithonehandwhileholdingdownthe
chargerbasewiththeother.
7.Unplugpowercordfromwalloutletwhenchargingiscomplete.
1187396-A-0213
Invacare®
5Maintenance
5.1Maintenance
WARNING!
RiskofInjuryorDamage
Thisproductisspecificallydesignedtominimizeroutine
preventivemaintenance.Topreventinjuryordamage:
Onlyprofessionalsofthehealthcarefieldor
personsfullyconversantwiththisprocesssuchas
factorytrainedpersonnelshouldperformpreventive
maintenanceorperformanceadjustmentsonthis
product,exceptfortasksdescribedinthismanual.
UsersshouldcontactyourdealerorInvacarefor
service.
5.2ServiceLife
WARNING!
RiskofInjuryorDamage
Theproducthasbeentestedfortheservicelifestatedin
thismanual.Useoftheproductbeyondthistimeperiod
maycauseinjuryorproductdamage.
ONLYusetheproductfortheservicelifestatedin
thismanual.DONOTexceedtheservicelifeofthe
product.
Performallmaintenanceaccordingtotheinstructions
andrecommendedscheduleinthismanual.
Theexpectedservicelifeofthisproductisthreeyearsofoperation
whenusedinaccordancewiththesafetyinstructions,maintenance
intervalsandcorrectusestatedinthismanual.Theeffectiveservice
lifecanvaryaccordingtofrequencyandintensityofuse.Maintenance
shouldbedoneatleasteveryweek.RefertotheMaintenance
sectionsinthismanual.
5.3CleaningandDisinfectionBetweenPatients
WARNING!
RiskofInjuryorDamage
Topreventinjuryfrominfectionordamagetobattery
charger:
Onlyqualifiedpersonnelshouldperformcleaningand
disinfectionofthebatterychargerandaccessories
betweenpatients.
Followtheseinstructionstoeliminatepossiblepathogen
exchangebetweenpatientsduetocontaminationof
componentsoraccessories.Preventivemaintenanceshould
alsobeperformedatthistimeifnecessary.
14
1187396-A-02
Maintenance
1.Cleanbatterychargerandaccessoriesasdescribedin
Maintenance.
2.Disinfecttheexternalhardsurfacesofthebatterycharger
andaccessoriesusingMadacide-FDGermacidalSolutionor
substantiallyequivalentproduct.
WARNING!
RiskofInjuryorDamage
Followthecleaning/disinfectantproduct
manufacturer’sinstructionsforuse,handling,
storageanddisposaloftheproduct.
Useofinappropriatedisinfectingproductsmay
degradedevicematerialsandnegativelyaffect
devicesafetyandperformance.
3.Performmaintenanceproceduresdescribedinthismanualand
itemsonPreventiveMaintenanceChecklist.
4.Checkbatterychargerforpossibleexternaldamageorsignsthat
itmayrequireserviceorrepair.
5.Beforerepackaginganddistributiontonewpatient,ensure
packagingcontentscontainthebatterychargerbase,ACpower
adapterandACpowercord.
5.4PeriodicInspections
Unplugbatterychargerfromelectricalpowersourcepriorto
performinginspection.
Inspect/examinetheexteriorofthebatterychargerandACpower
adapterforcracks,scratchesorotherdamage.Periodicallyinspect
allcomponentsfordamageorfrayedwires.
Ifdamageisfound,DONOTusethebatterycharger.Contactyour
providerforserviceand/orrepair.
Therearenouserserviceableparts.
5.5CleaningtheHousing
DANGER!
RiskofInjuryorDamage
Liquidwilldamagetheinternalcomponentsofthe
batterycharger.Toavoiddamageorinjuryfrom
electricalshock:
Removebatteryfromthechargerbaseandunplugthe
powercordbeforecleaning.
DONOTallowanycleaningagenttodripinsideany
openings.
DONOTsprayorapplyanycleaningagentdirectly
tothehousing.
DONOThosedowntheproduct.
CAUTION!
RiskofDamage
Harshchemicalagentscandamagethebatterycharger.
Toavoiddamage:
DONOTcleanwithalcoholandalcoholbased
products(isopropylalcohol),concentrated
chlorine-basedproducts(ethylenechloride),and
oil-basedproducts(Pine-Sol®,Lestoil®)oranyother
harshchemicalagents.Onlyusemildliquiddish
detergent(suchasDawn®).
1.Makesurethebatterychargerisunpluggedfromelectrical
powersourcepriortocleaning.
2.Cleanthebatterychargerhousingwithamildhouseholdcleaner
andnon-abrasiveclothorsponge.
3.Keepbatteryconnectionsdry.Keepthebatteryconnections
freeofdirt,lintanddebris.
4.Allowbatterychargertodrybeforeuse.
1187396-A-0215
Invacare®
TheACpoweradapterandACpowercordaretobe
cleanedinasimilarmanner.
5.6Storage
1.Storetherepackagedbatterychargerinadryarea.Refer
toSpecificationsinTechnicalDataforstoragetemperature
parameters.
2.DONOTplaceobjectsontopofrepackagedbatterycharger.
3.IndoorUseOnly.Placeonaflat,drysurface.
Retainallcontainerandpackagingmaterialsforstorageor
returnshipment.
161187396-A-02
AfterUse
6AfterUse
6.1RecyclingInformation
Thisproducthasbeensuppliedfromanenvironmentallyaware
manufacturerthatcomplieswiththeWasteElectricalandElectronic
Equipment(WEEE)Directive2002/96/EC.
Thisproductmaycontainsubstancesthatcouldbeharmfultothe
environmentifdisposedofinplaces(landfills)thatarenotappropriate
accordingtolegislation.
The'crossedoutwheeliebin'symbolisplacedonthisproductto
encourageyoutorecyclewhereverpossible.
Pleasebeenvironmentallyresponsibleandrecyclethisproduct
throughyourrecyclingfacilityatitsendoflife.
1187396-A-0217
Invacare®
7Troubleshooting
7.1Troubleshooting
Ifyourbatterychargerfailstooperateproperly,refertothefollowingchartforpossiblecausesandsolutions.Ifnecessary,contactyourprovider.
RefertothePlatinum™MobileOxygenConcentratorusermanualforadditionalinformationinregardstotroubleshootingthePlatinum
MobileOxygenConcentrator.
SymptomProbableCausesSolutions
Batterynotcharging.
Batterychargerstatuslightnotilluminated.
1.ACpowercordnotpluggedintooutlet.
2.Outletnotenergized.
3.ACpowercordnotpluggedintoAC
poweradapter.
4.ACpoweradapternotpluggedinto
batterycharger.
5.Batterycontactsnotfullyengaged.
6.Batterymalfunction.
1.Insertplugintooutlet.
2.Tryanotheroutlet.
3.Checkallpowerconnections.
4.Removeandreinsertbatterytoensure
batteryisinsertedcorrectly.
5.TryinsertingadifferentPOC1–110
batterypack.
6.Callprovider.
Batterynotcharging.
Batterychargerstatuslightisilluminated
yellow.
1.Batteryoutofchargingtemperature
range.
2.Batteryorbatterychargermalfunction.
1.Allowbatterytowarm/cooltoroom
temperatureforonehourandretry.
2.TryinsertingadifferentPOC1–110
battery.
3.Callprovider.
Batterynotcharging.
Batterychargerstatuslightisilluminatedsolid
green.
1.Batteryisalreadyfullycharged.
2.Faultybatteryfuelgauge.
1.Checkbatterychargestatususingbattery
fuelgauge.
2.Ifbatteryisnotfullycharged,try
reinserting.
3.TryinsertingadifferentPOC1–110
battery.
4.Callprovider.
181187396-A-02
Technicaldata
8Technicaldata
8.1Specifications
ChargerInputVoltage:20.0VDC
ChargerRatedCurrentInput:3.6A(MAX)
ChargerRatedDCOutputVoltage:16.8V(nominal)
ChargerRatedDCOutputCurrent:3.0A
ACPowerAdapterInput:100–240VAC,50–60Hz,1.6–0.8A
ExtensionCords:
Notpermitted
ChargerWidth:4.0in(10.2cm)
ChargerHeight:2.0in(5.1cm)
ChargerDepth:4.0in(10.2cm)
ChargerBaseWeight:0.45lbs(0.20kg)
PowerSupplyWeight:1.10lbs(0.50kg)
OperatingAmbientTemperatureandRelativeHumidity:41°Fto104°F(5°Cto40°C)andlessthan93%relativehumidity
(non-condensing)
RecommendedStorageandShippingEnvironmentalConditions:
Additionally,refertothePlatinumMobileOxygenConcentratoruser
manualforthebatterypackstorageandshippingconditions.
-13°Fto158°F(-25°Cto70°C)andlessthan93%relativehumidity
(non-condensing)
1187396-A-0219
Invacare®
Time:
BatteryChargeTime:
(Approximate)
Useattheextremesoftheoperatingtemperaturerangecan
leadtochargetimesofupto4hours
2hr20min
Productcomplieswiththefollowingstandards:IEC60601–1,AAMIES60601–1(UnitedStates),EN60601–1,CSA
C22.2No.60601–1(Canada),IEC60601–1–2,EN60601–1–2,EN
55011
CEMarking:ThisproductcomplieswithLowVoltageDirective2014/35/EUand
93/42/EECconcerningmedicaldevices.
ThelaunchdateofthisproductisstatedintheCEdeclarationof
conformity.
201187396-A-02
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

Invacare POC1–115–AZ User manual

Category
Rechargeable batteries
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI