USING THE UNIVERSAL TOOL (Cont.)
USING THE LIFTING TOOL
REMOVING THE INTERNAL COMPONENTS
USING THE LIFTING TOOL
The lifting tool assists in the installation and removal of the
Bio-Kinetic system from the Singulair Green tank. The
Bio-Kinetic system will need to be removed from the
clarification chamber periodically for cleaning and service.
To remove the Bio-Kinetic system, remove the clarification
chamber access cover and place it upside down on the
ground near the mounting riser. If the system is equipped
with Blue Crystal or Bio-Neutralizer feed tubes, carefully
remove each tube, one at a time. Lay each feed tube on the
inverted access cover. Do not allow the feed tubes to touch
each other. Remove the service cover from the
Bio-Kinetic system. Follow the instructions on the previous
page to disengage the locking lugs.
The universal tool is equipped with a fixed handle and a
movable handle. Lower the fixed handle into the open top of
the Bio-Kinetic system. The fixed handle of the lifting tool
should be aligned with two opposing locking lugs to allow
the tool to drop into the lifting rib on the Bio-Kinetic system.
Insert the end of the fixed handle that is opposite the flat
area on the Bio-Kinetic system into the lifting rib. Lower the
other end of the fixed handle down by the side of the flat
area and into the lifting rib. Turn the handle until the lifting
tool is engaged into the lifting rib. Guide the
Bio-Kinetic system out of the mounting riser as it is
being dewatered. Once completely dewatered, remove the
Bio-Kinetic system from the mounting riser.
USING THE DISASSEMBLY TOOL
The disassembly tool allows the deck plates, flow deck,
and inner baffle of the Bio-Kinetic system to be removed
for service without removing the entire system from the
clarification chamber. It is not necessary to dewater
the Bio-Kinetic system before removing the internal
components.
To remove the internal components, remove the
Bio-Kinetic system access cover and place it upside down
on the ground near the mounting riser. If the system
is equipped with Blue Crystal or Bio-Neutralizer feed
tubes, carefully remove each tube, one at a time. Lay each
feed tube on the inverted access cover. Do not allow
the feed tubes to touch each other. Remove the service
cover from the Bio-Kinetic system. Do not disengage the
locking lugs.
The universal tool is equipped with a fixed handle and a
movable handle. Lower the movable handle into the open
top of the Bio-Kinetic system. The movable handle of
the disassembly tool should be positioned so that each
end of the movable handle is beneath the plastic handles
on top of the flow deck. Lift the internal components with
the disassembly tool to remove them from the Bio-Kinetic
system. When service has been completed, use the
disassembly tool to lower the internal components back
into the Bio-Kinetic system.