RTU-4100

VeEX RTU-4100 User manual

  • Hello! I'm your chat assistant. I have analyzed the Software Release Notes document for the VeEX RTU-4100 OTDR Module and RTU-4000 Test Platform. This document outlines firmware and software updates, highlighting new features such as IPv6 support, enhanced monitoring capabilities, and multi-language support. I'm here to help you with any questions about the document or the device, its features, and capabilities such as OTDR testing and integration with the VeSion monitoring system. Feel free to ask!
  • What is the software update procedure?
    What is required to use the RTU-4000/4100 in a centralized monitoring system?
    What are the limitations of the latest software release?
    What kind of alarms does this product provide?
    Does it support remote software upgrades?
RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
1
RTU‐4100OTDRFirmware/SoftwareUpdates
TheRTU‐4000testplatformanditsfactory‐installedmodules(RTU‐4100)constantlyevolvetokeepupwithnewapplicationsand
advancedcapabilities.Gotowww.veexinc.comtodownloadthefullupgradepackagestokeepthemuptodate.Pleaserefertosoftware
upgradeprocedureattheendofthisdocument.
Softwareversion: 02.00.0001 January4,2022
ReleaseScope:
MajorRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSionand
requires:
RTU‐4000Platform:version02.00.0001
ProbeConfigurationTool:version1.5.0orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VesionServerversion:4.2.2.24767
VesionRTU410Server:version4.2.2.24742
VeSionHTML5Web:version7.0.6493
VeSionGIS:version1.0.0.290
Generalfeatures:
1.
RequiredforcompatibilitywithnewmajorRTU‐4000platformrelease02.00.xxxxtosupportnewerand
fasterhostCPUinnewly‐shippedplatformandtestmodules.
2.
AddedIPV6Support
Knownissuesorlimitations:
ThisreleaseislimitedtonewRTU4000/4100unitsshippedsinceJanuary2022.Thisversioniscurrentlyunderregression
andbetatestingformodulesshippedpriorto2022.
Softwareversion: 01.02.0040 November16,2021
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSionand
requires:
RTU‐4000Platform:version01.00.0009
ProbeConfigurationTool:version1.4.8orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionServerversion:4.2.2.24646
VeSionHTML5Webversion:7.0.6441
VeSionRTU410Serverversion:4.2.2.24659
VeSionGISversion:1.0.0.282

RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
2
GeneralFeatures
UpdateSORviewercomponentwithnewPONEventstab.
Requireconfirmationforalltypesofchangesduringmonitoringtest.
ShowVeSionprotocolversionsupportedbyRTUandsupportedbyserver(ifconnected)toRTU‐About.
Softwareversion: 01.02.0036 June10,2021
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSionand
requires:
RTU‐4000Platform:version01.00.0008
ProbeConfigurationTool:version1.4.7orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionServerversion:4.2.1.24193
VeSionHTML5Webversion:7.0.5978
VeSionRTU410Serverversion:4.2.0.24193
VeSionGISversion:1.0.0.232
GeneralFeatures
TheIP/DNS/VeSionserversettingsareread/storedinEEPROMinsteadofFLASHbymeansofaspecialplatform‐
providedtool(rtu4000config)
Softwareversion: 01.02.0033 March16,2021
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSionand
requires:
RTU‐4000Platform:version01.00.0005
ProbeConfigurationTool:version1.4.3orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionServerversion:4.2.1.24193
VeSionHTML5Webversion:7.0.5978
VeSionRTU410Serverversion:4.2.0.24193
VeSionGISversion:1.0.0.232
NewVeSionSystemfeaturesandimprovements:
Addedsupportofadvancedalarmprofilethresholds.
AddedBreakDetectionmonitoringperiodsettings.
Fixedremovingofflinedevices.
AddedRFTSHealth(Dashboardandself‐healthpage).
ShowsroutedetailsinAlarmeventevenafterdeletingroute.
RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
3
HandledsituationwithRTU4100withoutanyconnectedOTAU.
Createdandhandlednewsystemalarm–“OTAUChanged”.
NowRFTStriggersrescanforportwhenCX180Rlosessignalevenwhentheportisoff.
RebuildthebaselinedistancehandlinginAlarm&Datalog.
Addedbaselinedistancestobaselinestableinthedatabase.
StandaloneRTUoperation
AddedJapaneselanguagesupport.
NowshowsindicatorifdeviceisintegratedwithVeSion.
GeneralFeatures
Improvedtheendoffiberdetectionanalysis.
Softwareversion: 01.02.0022 August20,2020
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion.
Requires:
RTU‐4000Platform01.00.0005softwareversion
ProbeConfigurationTool1.4.2orlater(forthesoftwareupgrade)
ForRTUoperatingwiththeVeSionmonitoringsystem:
Vesion.Server.4.1.8.23196
Vesion.RTU410Server.4.0.3.23196
VeSionHTML7.0.5307
StandaloneRTUoperation/features
AddedOTAUcascadingsupportfeature.
UpdatedOTDRmeasurementlibraries.
AddedRussianlanguagesupport.
AddedRealTimemeasurementsupport.
Showsintermediatetraceupdateduringmeasurement.
TooltipnowshowsinChrome.
Addedoptionto‘Measure’anywayinstandardMeasurementpageifbadconnectiondetected.
Improvedfiledownload,reportsanddownloadabletracesZIPfilenaming.
‘Test’buttononintegrationpagesnowworkswhenAuthorizationisenabled.
AddedsupportofDNSconfigurationbeingstoredinEEPROM.
AddedwatchdogtimeoutsformostcallstoOTDRmeasurementlibrarytover.5.79.
Addedmonitoringeventlocationthresholds/limit.
Fallbacktocreatingtemporaryorin‐memorydatabaseiffiledatabasecreationfails.Added.sysfailure‐filetolog‐
packmakingitmoretoleranttoerrors.Allowssourcedirectoriestobemissing.
AddedOTAUIPaddresstodropdownlist.
ExtendedbaselinesnowregisterasEOFalarminproactivemonitoringmodeonVeSion.

RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
4
Softwareversion: 01.02.0013 May4,2020
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion.
Requires:
RTU‐4000Platform01.00.0003softwareversion
ProbeConfigurationTool1.4.0orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionServerversion:4.1.3.21851
VeSionHTML5version5.1.4860
VeSionRTU410Serverversion:3.1.7.21923
StandaloneRTUoperation
NewOTDRTraceAnalysisAlgorithm(fixedwrongEOFlocations)
Softwareversion: 01.02.0012 March26,2020
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion.
Requires:
RTU‐4000Platform01.00.0002‐LTE2softwareversion
ProbeConfigurationTool1.4.0orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionServerversion:4.1.3.21851
VeSionHTML5version5.1.4860
VeSionRTU410Serverversion:3.1.7.21923
NewVeSionSystemfeaturesandimprovements:
AddedTCP/IPOTAUsupport.
Improvedstability:OTDRwillresetaftermultiplesubsequentfailuresdetected;ServiceswillrestartincaseHTTP
APIstopsresponding.
UpdatedOTDRmeasurementlibraries:improvedautomaticanalysis.
OTDRmeasurementlibrariesversionsarenowreportedtoVeSionserver.
StandaloneRTUoperation
AddedGeneralmeasurementparameters(JobID,CableID,FiberID,Operator,etc.)intheHTTPAPIandUI.
LogfilesbundlecannowbedownloadedviaHTTPAPIandUI.

RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
5
Softwareversion: 01.02.0010 January2,2020
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion.
Requires:
RTU‐4000Platform01.00.0001softwareversion
ProbeConfigurationTool1.3.9orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionHTML5version5.1.4718
VeSionServerversion:4.09.29909
VeSionRTU410Serverversion:3.1.3.21201
NewSystemfeaturesandimprovements:
ChangedVeSionprotocoltosupportrequiredopticalqualitysettings.
StandaloneRTUoperation
AddedabilitytoremovefailedOTDRmeasurements.
Correctedmeasurementoffsetissue.
AddedoptionalHTTPauthentication.
Addedemailnotification.
AddedabilitytochangeRTUnetworksettings.
Changingnetworksettings,dateandtime,RTUnameislimitedtowhenHTTPauthorizationisenabled.
Softwareversion: 01.02.0005 July11,2019
ReleaseScope:
FormalRelease.Generalavailability
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion.
Requires:
RTU‐4000Platform01.00.0001softwareversion
ProbeConfigurationTool1.3.5orlater(forthesoftwareupgrade)
ForRTUinstalledintheVeSionmonitoringsystem:
VeSionHTML5version5.1.4179
VeSionServerversion:4.08.20252
VeSionRTU410Serverversion:3.1.2.20252
Newfeaturesandimprovements:
ImprovedthestatusofLEDsonthefrontpanel.
‐ ThePowerLEDisalwaysGreenaftertheprobeispoweredOn.
 TheStatusLEDindicatesthealarmstatusfortheRTU.TheLEDisGreenwhentherearenoalarms,andit’s
Redwhenanalarmispresent.
V‐Scoutmodeisnowastandardfeature.
RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
6
ResolvedissuewhereRTUintermittentlystopsmonitoringorsupportingon‐demandtestsbutrespondstoping.
AllcheckboxesarevisiblewithborderappliedwhenusingChromeinAdvancedOTDRmeasurementSettings.
Minorchangestosometextintheweb‐browser.
Web‐browserMonitoringTestbaselineiscreatedusingV‐Scoutonly.IfAutoorManualtestrequired,thenmust
performon‐demandtest;downloadbaselinefileanduploadtoMonitoringtest.
Improveddialogboxes’alignment/positiontoimprovevisibility.
Addedhardwarewatchdogtimertoimproveproberobustnessagainstsystemfailures(VeSiononly).
Addedheart‐beatmessagestotheVeSion‐RTUprotocolforfasterdetectiononnetworkfailures(VeSiononly).
NowsupportsthenetworkactivitymonitorandrestartsPHY/deviceifthenetworkisidlefortoolong.
AddedOfflinemonitoring.WhenRTUprobelosesIPconnectiontoVeSionserver,RTUshouldcontinue
monitoring.Ifabreakisdetected,storetestresultsandbreakdistanceofthefiberbreak.Forroutinefiber
degradationusingProactiveScanmode,saveallresultstotheSDcard,ifavailable.WhenIPserverconnectionis
re‐established,automaticallyuploadalltestresultsandstatustotheVeSionserver.
AddedabilitytoremotelyupgradeRTU‐4000/4100softwareusingVeSion.ThisfeaturewillonlyworkifRTU‐
4100softwareversionis01.02.0001orhigher.
AddedtheremoterebootcommandwhenusingVeSion.
AddedthePONtoONUmonitoringsupporttotheVeSionprotocol.
ImprovedtheUSBcommunicationbetweenthechassisandthemodule.
Addedsupportfornewchassis(serialnumberswithTLDprefix)whichhavethedual48VDCordual15VDCpower
supply.
Softwareversion: 01.01.0001 March20,2019
ReleaseScope:
InitialRelease.Generalavailability
RequiresRTU‐4000version01.00.0001software.
Note:ProbeConfigurationTool1.3.3orlaterisrequiredforthisversiontoinstall/upgradeallRTUsoftware.TheRTU
USBdriverwillneedtobeinstalledonPCifconnectingviaserialinterface.Alltestmodules(RTU‐4100)mustbe
upgradedtotheirrespective01.01.0001versionstoassurecompatibility.
RTU‐4000/4100isdesignedtooperateinStandalonemodeorinacentralizedmonitoringsystemsuchasVeSion:
VeSionHTML5version5.0.3498
VeSionServerversion:4.0.7.19579
VeSionRTU410Serverversion:3.0.9.19579
Generalfeatures:
1.
ThenewRTU‐4100whencombinedwithRTU‐4000chassissupportsOTDRtestcapabilities.
2.
TheRTU‐4000/4100OTDRcanbeusedforOn‐DemandorMonitoringtestapplications.
3.
TheRTU‐4000/4000canbeinterfacedwiththeOXA‐4000orOX4000opticalswitches.
4.
TheRTU‐4000/4100canoperateinManual,Automode(Point‐to‐PointorPON)andVScout.
5.
TheRTU‐4000/4100includesAPIcommandsforcustomerswhoprefertowritetheirownRFTSsoftware.
RTU‐4100OTDRModule
SoftwareReleaseNotes
 
2827LakeviewCourt,Fremont,CA94538,USATel:1.510.651.0500Fax:1.510.651.0505
www.veexinc.com
7
References 
UpdatingtheRTU‐4000/RTU‐4100SoftwareusingtheProbeConfigurationTool
WARNING:Thesoftwareupdatingprocedurereformatstheplatform’sinternalstorageandcleansupalltestresultsandprofiles.
Remembertosaveallimportantfilespriortoupdatingthesoftware.
Onceyouhaveobtainedanduncompressedtheupdatepackagefiles(install_rtu4000_platform.shforthePlatformand
install_rtu4100_otdr.shfortheOTDRmodule),thesoftwareupdateprocedurecanbeperformedusingtheProbe
ConfigurationToolapplication.VeEX,Inc.willprovideVeSionupgradesoftwaretoanycustomerwithacurrent,active
softwaremaintenancelicense.ContactVeEXCustomerCaretorenewyourlicenseifithasexpiredandtogetthelatest
VeSionsystemsoftware.
NOTE: IfinstalledinyourPC,somefilecompressionagents(applications) may show the resultingfile as acompressedSH
file,butthereisnoneedtoexpandthefileanymore.Keepitasis.
TheRTU‐4000mustbeconnectedtopower(AC/DCor‐48VDC)duringtheentireupgradeprocess.DONOTturnitoffat
anytimeduringtheupgradingprocess.
i.
OpentheProbeConfigurationToolapplication
ii.
FollowtheupgradingprocedureintheRTU4000/4100UserManual,Section16.0.
iii.
First,installtheplatformsoftware.
WARNING:Thesystemupdateprocedurereformatstheplatform’sinternalstorageandallresultsandprofilesareerased.
Pleasesaveallimportantfilespriortoupdatingthesystemsoftware.
iv.
Nextinstallthemodulesoftware.
NOTE: Themodulesoftwaremustbere‐installedafteranyPlatformsoftwareupgradehasoccurredeven
ifnoupgradeisrequiredforthemodule.
v.
TurnthetestsetOFFforseveralminutes,andthencheckusingtheProbeConfigurationToolthatthe
softwarewasproperlyinstalled.
©2019‐2022VeEXInc.Allrightsreserved.
VeEX,VePAL,RXT,MTT,ReVeal,VeExpress,V‐SAM,Multi‐BERT,Vlogos,SunriseTelecom,SunSet,MTTandFiberizeraretrademarksorregistered
trademarksofVeEXIncorporated,oroneofitsaffiliates.Allothertrademarksorregisteredtrademarksarethepropertyoftheirrespectiveowners.
Somefeatureslistedinthisdocumentrequiresoftwareoptionsthatmayrequirepaidactivationorlicenseandmayormaynotbeavailableinall
products.VeEXInc.,reservestherighttochange,withoutnotice,productofferingsorspecifications.
/