CAUTION
The warranty does not cover damage
resulting from improper handling.
5 N max.
5 N max.
~1 N
~1 N
Shipping brackets must
stay during the mirror
set up.
Do not apply excessive
torque on the shipping
brackets.
50 mN.m max.
Mirror Installation Using
Do not apply forces shown below
as excessive forces can ruin the
sensor.
Do not apply excessive force on the
mobile part of the mirror mount.
The sensor is fragile and will be
destroyed by such an action.
Once the shipping
brakcets are removed,
only handle by the
mirror mount base.
To remove or replace the mirror, secure the
shipping brackets prior to handling the mobile
part of the mount.
The protective yellow shipping
brackets must be set in
contact with the mobile part
of the mirror mount before
locking to the base.
CONEX-AG-M100D
USERS MANUAL
EDH0270En1032 — 11/17 2
C
ONEX-AG-M100D CONEX-AGAP Controller with AG-M100D Mirror Mount
The CONEX-AG-M100D is a piezo motor actuated mirror mount with an integrated controller/driver for 1”
diameter optics (0.5” diameter with the UPA1-0.5 adapter). For out-of-the box control, the CONEX-AGAP
controller is preconfigured and delivered with an Agilis AG-M100D mirror mount with a built-in, pan and
tilt, absolute angular position sensor.
The AG-M100D mirror mount can either be fastened on a pedestal post of the M-PS Series or a fixing
washer, supplied.
The CONEX-AGAP is a very compact and inexpensive dual axis motion controller with the same driver as
the proven Agilis AG-UC2 2-axis driver. In addition, the CONEX-AGAP includes a closed-loop algorithm to
achieve high angular repeatability of mirror positioning. The controller comes with the familiar CONEX
GUI / NSTRUCT, simple and intuitive to use and conveniently accessible via USB, which also supplies
power to the controller.
An outstanding absolute position closed loop adjustment capability
The CONEX-AG-M100D mirror mount features an innovative, miniature, absolute position sensor. With a
footprint similar to other Agilis mirror mounts, it offers an angular positioning repeatability within a few
millidegrees, even after a system reset.
This position recovery capability is a key feature of this product: the CONEX-AGAP closed-loop algorithm,
combined with the absolute position sensor, provides a system repeatability of 0.01º.
Fine adjustment performance
Like its controller, the mirror mount is very compact, but is capable of ±0.75° travel on both axes with an
angular open loop adjustment sensitivity better than 2 µrad which comes directly out of the box running
the easy to use GUI.
Stability
When adjusted, the angular stability of the AG-M100D absolute position mirror mount is the same as an
ULTIMA mirror mount. The thermal stability of the AG-M100D is in the range of 5 µrad/°C.
Compact Bidirectionnal ABSOLUTE POSITIONNING
Mirror Mount
3 EDH0270En1032 — 11/17
C
ONEX-AG-M100D CONEX-AGAP Controller with AG-M100D Mirror Mount
.24
(6)
ø.50
(12.7)
.20
(5)
ø1.00
(25.4)
ø.44
(11.1)
NYLON TIP SET SCREW
FOR MIRROR MOUNTING
Stage Specifications
Dual axis travel range ±0.75°
Closed-loop MIM 0.001º
Open-loop MIM 2 µrad
Bi-directional repeatability 0.01º
M
aximum speed >0.4 °/s
T
hermal stability 5 µrad/°C
Dimensions
UPA1-.5
Optional 1” to 0.5” Adapter
NOTE
Refer to the CONEX-AGAP manual for
instructions on closed-loop and open-loop
operations.
3.67
(93.2)
1.97
(50)
2.09
(53)
1.57
(40)
.91
(23)
.53
(13.5)
2 HOLES M3 THD
BOTH SIDES:
2 HOLES M3 THD
MINI-USB
CONNECTOR
1.10
(28.0)
1.0
(25.4)
2.10
(53.4)
2.09
(53.2)
1.09
(27.8)
ø.96
(24.5)
.10
(2.6)
ø1” OPTICS
2 HOLES C’BORED
FOR 8-32 (M4) SCREW
F
IXING WASHER
1.20
(30.4)
.40
(10.2)
.24
(6)
NYLON TIP SET SCREW
FOR MIRROR MOUNTING
.56
(
14.2)
EDH0270En1032 — 11/17 4
C
ONEX-AG-M100D CONEX-AGAP Controller with AG-M100D Mirror Mount
Axis Convention
Shipping Spacer
Shipping wedges are delivered with the AG-M100D
mirror mount for transportation and handling. It is
recommended to keep them in place until the
mirror is installed.
These wedges lock the mobile part of the mirror
mount against mechanical limit stops, travel U(q
X
)
= V(q
Y
) 1°.
Proper Working Conditions
Do not apply additional loads to the sensor other
than the normal optics payload of 15 grams max.
Never apply force on the moving part.
Isolate from shock, vibration or excessive
acceleration.
Operating Temperature: 15 to 35 °C.
EU Declaration of Conformity
Please refer to the “CONEX-AGP - Introduction,
Safety & Service” manual supplied on the CD-ROM
to have a complete description of the EU
Declaration of Conformity.
NOTE
This product complies with the RoHS directive
(Restriction of Hazardous Substances).
RoHS
Compliant
North America & Asia
Newport Corporation
1791 Deere Ave.
Irvine, CA 92606, USA
Sales
Tel.: (800) 222-6440
e-mail: sales@newport.com
Technical Suppor t
Tel.: (800) 222-6440
e-mail: tech@newport.com
Service, RMAs & Returns
Tel.: (800) 222-6440
E
Europe
MICRO-CONTROLE Spectra-Physics S.A.S
9, rue du Bois Sauvage
91055 Évry CEDEX
France
Sales & Technical Support
Tel.: +33 (0)1.60.91.68.68
e-mail: france@newport.com
Service & Returns
Tel.: +33 (0)2.38.40.51.55
Visit Newport Online at:
www.newport.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Newport CONEX-AG-M100D Mirror User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI