  • Hello! I am an AI chatbot trained to assist you with the luminii Kendo L Wet Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
REV0.1 02272020*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Instruction page index:
Fixed mounting clip installation
Adjustable hinge installation
Connect to Power
Power feed layout guide
2
3
4
5
Page 1 of 5
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Kendo M Wet with fixed clip mounting
Kendo M Wet with adjustable hinge mounting
Installation Instructions for Kendo S Wet, Kendo M Wet, Kendo L Wet, & Kendo XL Wet
Models KSW-XX, KMW-XX, KLW-XX, & KXLW-XX
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR WET LOCATIONS
5. SURFACE MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE
7. TYPE IC
8. INHERENTLY PROTECTED
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Page 2 of 5
Fixed mounting clip installation
2
2.1 If necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option reference dimensions for hole
size. Then snap the fixture into the fixed mounting clip to secure in place. Diagram on the right side illustrates the common way of connecting multiple
fixtures to each other, depending on the location of the power feed wires.
surface
- end power feed with wire leads
fixed mounting clip
pass through hole
for power feed
fixture
fixture 1 fixture 2
fixture 1 fixture 2
fixture 1 fixture 2lead wires
2.1
1
1.1 Determine the location of where the fixture(s) will be installed. Lay the fixture(s) on the surface, and make any necessary reference marks for the fixed
mounting clips (or if using the fixed 45° degree mounting clip). Make marks 4" from each end of the fixture(s) and also every 30" in between.
1.2 Lay the fixed clip onto the reference mark points and secure using the provided hardware.
1.1
flathead screw
4” 4”every 30”
fixed mounting clip
fixture
surface fixed mounting clip
1.2
1.2
fixed 45° degree
mounting clip
- bottom power feed with wire leads
lead wires
lead wires
- side power feed with wire leads
to power supply
to power supply
to power supply
Male quick
connect end
0.45”
Female quick
connect end
0.39”
0.53”
Wire Lead
0.20”
Quick Connect/
Wire Lead
dimensions
Installation Instructions for Kendo S Wet, Kendo M Wet, Kendo L Wet, & Kendo XL Wet
Models KSW-XX, KMW-XX, KLW-XX, & KXLW-XX
REV0.1 02272020
REV0.1 02272020
1
1.1 Determine the location of where the fixture(s) will be installed. Lay the fixture(s) on the surface, and make reference marks for the mounting clips. Make
marks 4" from each end of the fixture(s) and also every 30" in between.
1.2 Slightly loosen the 2 screws on the side on adjustable bracket. Lay the bracket onto the reference mark points and secure using the provided hardware.
1.1
4” 4”every 30”
adjustable hinge
mounting clip
fixture
surface
loosen screws
flathead screw
1.2
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR WET LOCATIONS
5. SURFACE MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE
7. TYPE IC
8. INHERENTLY PROTECTED
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Page 3 of 5
Adjustable hinge mounting clip installation
2
surface
fixture 1 fixture 2
fixture 1 fixture 2
fixture 1 fixture 2
lead wires
- bottom power feed with wire leads
lead wires
lead wires
adjustable
hinge bracket
bottom power feed
fixture
2.1
2.1 If necessary make any pass through holes for wire lead/connector to the surface, depending on the power feed option reference dimensions for hole
size. Then rotate fixture to the appropriate degree, followed by tightening the screws on the side. Then snap the fixture into the fixed mounting clip to
secure in place. Diagram on the right side illustrates the common way of connecting multiple fixtures to each other, depending on the location of the
power feed wires.
- end power feed with wire leads
- side power feed with wire leads
to power supply
to power supply
to power supply
Male quick
connect end
0.45”
Female quick
connect end
0.39”
0.53”
Wire Lead
0.20”
Quick Connect/
Wire Lead
dimensions
Installation Instructions for Kendo S Wet, Kendo M Wet, Kendo L Wet, & Kendo XL Wet
Models KSW-XX, KMW-XX, KLW-XX, & KXLW-XX
REV0.1 02272020
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR WET LOCATIONS
5. SURFACE MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE
7. TYPE IC
8. INHERENTLY PROTECTED
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Page 4 of 5
Connect to Power
12.1 Connect +24 VDC red wire from the fixture
to the power supply +24 VDC red wire
with a wire nut. Connect -24VDC black
wire from the fixture to power supply -
24VDC black wire with a wire nut.
2
class II
power
supply
24 VDC
120 VAC
2.1
to fixture
+24 VDC RED
-24 VDC BLACK -24 VDC BLACK
+24 VDC RED
Option 2- Feed wire whip to the power supply.
OR
male quick connect. Feed male quick connect
wire through conduit to power supply.
Option 1- Secure female quick connect to
female quick
connect male quick
connect
to power supply
wires from fixture
1.1
1.1
1.1 Follow one of the two options to connect the fixture to the
power supply.
Installation Instructions for Kendo S Wet, Kendo M Wet, Kendo L Wet, & Kendo XL Wet
Models KSW-XX, KMW-XX, KLW-XX, & KXLW-XX
REV0.1 02272020
*LUMINII RESERVES THE RIGHTS TO CHANGE SPECIFICATION & INSTRUCTION WITHOUT NOTICE
Please read all instructions prior to installation and keep for future reference!
1. PRODUCT TO BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
2. USE ONLY WITH CLASS 2 POWER UNIT
3. 24 VOLTS DC
4. SUITABLE FOR WET LOCATIONS
5. SURFACE MOUNT ONLY
6. SUITABLE FOR INSTALLATION WITHIN THE CLOSET STORAGE SPACE
8. INHERENTLY PROTECTED
7. TYPE IC
7777 Merrimac Ave
Niles, IL 60714
T 224.333.6033
F 224.757.7557
www.luminii.com
Page 5 of 5
power supplies at the
end of the run
power supplies in the
middle of the run
consecutive layout,
NOT RECOMMENDED
Multiple powerfeed layouts
power supply
low voltage wires
fixture 1
fixture 1 fixture 2
low voltage wires
power supply
power supply
low voltage wires
fixture 1
power supply
low voltage wires
fixture 2
Installation Instructions for Kendo S Wet, Kendo M Wet, Kendo L Wet, & Kendo XL Wet
Models KSW-XX, KMW-XX, KLW-XX, & KXLW-XX
REV0.1 02272020
/