  • Hello! I've reviewed the installation notes for the DANLERS CESF PIRAR occupancy switch. This document covers how to install, configure and troubleshoot the device. I'm familiar with its features, such as the adjustable LUX threshold, time lag, and sensitivity. I'm ready to help with your questions!
  • What can cause the load not to switch on?
    What can cause the load to switch on when nobody is present?
    What is the maximum switching capacity for low energy lamps?
Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.6ampsovercurrent,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Ceiling Surface PIR occupancy switches
CESF PIRAR
DANLERSceilingsurfacepassiveinfra-redoccupancyswitches(CESF
PIRAR)canbeceilingmountedonasquarepattressbox(DANLERS
code:PABO).
TheCESFPIRARincorporatesapassiveinfra-redquadsensorto
detectmovementofawarmbodywithinitsdetectionzone(diagram
A)andaphotocelltomonitortheambientlightlevel.
Upondetectingmovement,iftheambientlightisdarkenough,theCESF
PIRARwillswitchtheloadon.Theambientthresholdcanbesetby
theusertobetweenapproximately100luxandinnitelux(photocell
inactive)viatheLUXadjuster(diagramB).
Ifnomoremovementisdetectedwithinapre-selectedtime,then
theCESFPIRARwillswitchtheloadoff.Thistimelagcanbesetvia
theTIMEadjusterto10seconds,20s,40s,1minute15seconds,
2m30s,5m,10m,20mor40minutes(diagramB).
CESFPIRARalsoincorporatesasensitivityadjuster,labelled‘SENS’,
toreducetherangeandsensitivityofdetection(diagramB).
Loading
TheCESFPIRARcanbeconnectedtoa230V(+/-10%)50Hz(+/-
10%)acsupply
Theycanswitchupto6amps(1500W)of:
• Fluorescentlamps,highfrequencyorswitchstart
• Incandescentormainshalogenlamps(recommendedwithintegralsafetyfuse)
• Electronicorwirewoundtransformers.
Theycanalsoswitchupto:
• 2amps(500W)oflowenergylamps:CFL,LED,2Detc.
• 1amp(250W)ofmetalhalidelampsorfans.
Theyhaveaminimumswitchingcapacityof0.5W,forlessthanthisaGold
relayversionshouldbeused,seeVariantssection.
Forlargerloads,thePIRcanbeusedtoswitchacontactor.
22/07/13 INS944AR CESF PIRAR
Variants
AsDANLERSdesignandmanufactureintheUK,variantscanbesupplied,
codedbythefollowingsufxesandappliedinthisorder:
• 12Vor24V  12Vor24V(acordc)operation
• VF VoltFreecontacts
• GOLDorLG GoldorLogicGoldcontacts
• NC NormallyClosedcontacts
Variantdetailsarecoveredinanenclosedaddendumsheetifapplicable.
Troubleshooting
The load will not switch on:
• TheLUXadjusterissettoolowandisinhibitingtheswitch.
• TheSENSadjusterissettoolow.
• ThemovingbodyisnotemittingmoreIRthanthebackground.
  (Personwearinginsulatingclothinginawarmenvironment)
• PersonistoofarfromthePIRswitch,seedetectiondiagram.
• Personismovingunusuallyslowly(perhapswhentesting).
The load switches on when nobody is present:
• Heatercausinginfra-redvariationsinacoldsmallroomorceilingvoid
 drafts,fans,orsealeddoorscausingairmovement.
  Reducethesensitivityadjusterorconsiderusingthe
  CESFPIRAR2Ddoubledetectionversion.
• PleasecontactDANLERSforfurthertechnicalsupport.
Installation procedure
1.Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
2.POSITIONING:The CESF PIRAR should be installed to achieve
correctcoverageofthearea,seediagramA.
Ifthephotocelloverride
facilityisrequired,theswitchmustbelocatedaboveanareawhere
daylightcangivegreaterilluminationthanthearticiallight.Avoid
locatingthisproductwhereitisexposedtowindyordraftyconditions
(exposedlobbies,openceilingvoidsornearventilationfans)ornear
heatsources.TocoverlargeareasCESFPIRARsshouldbespaced
ina5metregridformation.
3.ThegreatestenergysavingswillbemadeifeachCESFPIRAR
controlsanindependentsetoflamps.Theycanbewiredinparallel
but this should ideally be limited to three, see diagram D.
4.Makesurethepowerisisolatedfromthecircuit.TheCESFPIRAR
shouldbeconnectedasshownindiagramsC&D:
L-Livein.N-Neutralin.SL-SwitchedLineout.
Start-up mode
WhentheCESFPIRARispoweredup,itwillswitchontheloadfor1
minute,theloadwillthenswitchoffandtheCESFPIRARwillenterits
OperatingMode.Ifamanualoverride-offswitchispositionedbefore
theCESFPIRARinthecircuit(diagramsC&D,note1)itwilldothis
eachtimethewallswitchisswitchedon.Alternatively,ifthewallswitch
isplacedafterthePIR(diagramsC&D,note2)itwillnotenterthe
start-up mode each time.
Time and Lux set-up
Forconvenience,ensurethattheTIMEissettotheminimumwhen
settinguptheLUXlevel.AfterwardssettheTIMEtoavaluesuitable
fortheapplication,makingreferencetodiagramB.
TheLUXisbestsetupwhenthelocalambientlightisatapproximately
theminimumdesiredworkinglightlevel,aluxmeterplacedonthesurface
undertheCESFPIRARmayhelp.WiththeLUXsetfullyclockwise
waitfortheCESFPIRARtoswitchoff.RotatetheLUXadjusterslowly
anticlockwise(-to+),whilstwavingyourhandapproximately1mbelow
thePIR,untiltheloadswitcheson.
L
load
Note 1: Optional
manual wall switch
for overriding off.
Note 2: Alternative
position for optional
wall switch
N
230 VAC
L
N
SL
TIME
min max
LUX
max min
SENS
min max
20s
40s
1m15s
2m30s
5m
10m
10s
20m
40m 100
1000
66% 100%
Typical settings
up to 5m
up to 8m
Strong detection zone
i.e. person moving arm
or walking towards PIR
Secondary detection zone
i.e. person walking
perpendicular to PIR
For optimum coverage
recommended mounting
height: 2.4 to 5m
load
Note 1: Optional manual wall switch
for overriding off
Note 2: Alternative
position for optional
wall switch.
L
N
230 VAC
L
N
SL
L
N
SL
L
N
SL
A: Detection diagram
C: Wiring diagram,
single PIR
D: Wiring diagram, multiple PIRs
B: Adjusting time, lux
and sensitivity
/