Rocstor Prestige Specification

Category
Uninterruptible power supplies (UPSs)
Type
Specification

power your future
PRESTIGE
HighFrequencyOnLineUPS
UserManual
1,000VA
2,000VA
3,000VA
ROCPOWER
PRESTIGE‐ usermanual
2
TableofContents
IMPORTANTSAFETYINSTRUCTIONS ..................................................3
CHAPTER1 .........................................................................................5
FrontDisplayPanelExplanation.........................................................5
RearPanelExplanation.......................................................................7
CommunicationPortExplanation ......................................................8
TheRS232InterfaceSettings..............................................................8
ThePinAssignmentsofTrueRS232Type ..........................................9
CHAPTER2 .......................................................................................10
Unpacking.........................................................................................10
InstallationLocation .........................................................................10
StorageInstructions .........................................................................11
CHAPTER3 .......................................................................................12
Setup…..............................................................................................12
OperationTestandInstallationInstruction .....................................12
CHAPTER
4 .......................................................................................13
ProductIntroduction........................................................................13
SNMPSlot.........................................................................................13
CHAPTER5 .......................................................................................14
HowtheUPSWorks .........................................................................14
WhenUtilityisNormalFigure1 ....................................................14
UtilityFailureandRecoveryFigures2and3.................................14
OverloadConditionFigure4..........................................................15
AbnormalOutputConditionFigure5............................................15
CHAPTER6 .......................................................................................17
Troubleshooting ...............................................................................17
Maintenance.....................................................................................18
CHAPTER7 .......................................................................................19
Communication ................................................................................19

HardwareInstallation.......................................................................19
SoftwareInstallation ........................................................................19
CHAPTER8 .......................................................................................20
Specifications....................................................................................20
RecyclingtheUsedBattery ..............................................................22
CHAPTER9 .......................................................................................23
LIMITEDWARRANTY.........................................................................23
TECHNICALSUPPORTINFORMATION ..............................................28
TrademarksAcknowledgements......................................................29
Copyrights.........................................................................................29
ContactInformation .........................................................................30
2
ROCPOWER
PRESTIGE‐ usermanual
3
IMPORTANTSAFETYINSTRUCTIONS
PLEASE,SAVETHESEINSTRUCTIONS
Thismanualcontainsimportantinstructionsthatshouldbefollowedduringunpacking,
installationandmaintenanceoftheUPSandbatteries.
ImportantNotices
ToensuresafetyinallapplicationswhereaUPSishardwiredtotheelectricalsupply,the
connectionsbetweentheUPS
andtheelectricalsupplyshouldbemadebyaqualified
electricalcontractor.
ThoseUPSsystemssuppliedwithafactoryinputleadcanbesafelyconnectedtothewall
outletbythepurchaser.
TheUPShasitsowninternalenergysource(battery).Shouldthebatterybeswitchedon
whennoAC
powerisavailable,voltagewillbeattheoutputterminals.
EnsurethattheACutilityoutletiscorrectlywiredandgrounded.
EnsurethattheinputvoltageoftheUPSmatchesthesupplyvoltage.
Useacertifiedinputpowercablewiththecorrectplugsandsocketsthatmatchesthe
voltage
system.
Donotopenthecaseastherearenoserviceablepartsinside.Openingthecasewillvoid
thewarranty.
AnyattempttorepairtheUPSunitbysomeo neother thananauthorizedtechnicianshall
voidthewarranty.
ToeliminateoverheatingoftheUPS,keepallventilationopeningsfreefrom
obstruction,
anddonotstoreanythingontopoftheUPS.KeeptheUPS8inches(20cm)awayfromthe
wall.
EnsuretheUPSisinstalledwithintheproperenvironmentasspecified(040°Cor3240
o
F
and3090%noncondensinghumidity).
DonotinstalltheUPSindirectsunlight.Thewarrantymaybevoidifthebatteriesfail.
InstalltheUPSindoorsasitisnotdesignedforoutdooruse.
Dusty,corrosiveandsaltyenvironmentscandamagetheUPS.
InstalltheUPS
awayfromobjectswhichgiveoffexcessiveheatandareaswhichare
excessivelywet.
Liquidsspilledand/orforeignobjectsdroppedintotheUPSwillvoidthewarranty.
Thebatterywilldischargenaturallyifthesystemisunusedforanylengthoftime.
TheUPSshouldberechargedevery2
3monthsifunused.Ifthisisnotdone,thewarranty
willbevoid.WhentheUPSisusedregularly,thebatterieswillbeautomaticallyrecharged
andkeptintopcondition.
ThisUPShasbeendesignedandconstructedtoprotectyourassetsfromthewiderangeof
poweraberrationsexperienced
onutilitypowerlines.Takecaretoinstallandmaintainthe
systemcorrectlybyyourlocaldistributor.
Intendedforinstallationinatemperaturecontrolledenvironment.
ROCPOWER
PRESTIGE‐ usermanual
4
Servicingofbatteriesshouldbeperformedorsupervisedbypersonsknowledg eableabout
batteriesandtherequiredprecautions.Keepunauthorizedpersonnelawayfrombatteries.
Whenreplacingbatteries,replacewiththesamenumberandtype.
CAUTIONDoNOTdisposeofbatteryorbatteriesinafire.Thebatterymayexplode.
CAUTIONDoNOTopenormutilatethebatteryorbatteries.Releasedelectrolyteisharmfulto
theskinandeyes.Itmaybetoxic.
CAUTIONRiskofElectricShockDoNOTremovethecover.Therearenouserserviceable
parts.Referservicingtoqualifiedtechnicians.
CAUTIONRiskof
ElectricShockThebatterycircuitisNOTisolatedfromAC.Hazardous
voltagemayexistbetweenthebatteryterminalsandground.Testbeforetouching.
CAUTIONAbatterycanpresentariskofelectricalshockandhighshortcircuitcurrent.
CAUTIONKeepchildrenawayfromthisproduct.
CAUTION
HEALTHCARETHEUPSISNOTTOBEUSEDINPATIENTCAREAPPLICATIONS:The
Rocpowerproductyoupurchasedwasnotdesignedfordirectorindirectpatientcareand
treatment.DONOTusethisproductwithanyequipmentusedtodirectlyorindirectlytreat
orcareforapatient.
CAUTION
Topreventpersonalinjuryorpropertydamage,donotcarryormovetheUPSby
thehandleorthefrontcover.
CAUTIONTheUPSisdesignedtobeusedwithcomputerloadsonly.
CAUTIONDoNOTconnectalaserprintertotheUPSoutlets.
TheFollowingprecautionsshould
beobservedwhenworkingonbatteries:
Removewatches,rings,orothermetalobjects.
Usetoolswithinsulatedhandles.
Wearrubberglovesandboots.
Donotlaytoolsormetalpartsontopofbatteries.
Disconnectchargingsourcepriortoconnectingordisconnectingbatteryterminals.
WARNING:
Thisis
aClassAUPSProductinadomesticenvironment
Thisproductmaycauseradiointerference.Shouldthisoccur,theusermaybe
requiredtotakeadditionalmeasures.
CAUTIONToreducetheriskoffire,connectonlytoacircuitprovidedwith20amperes
maximumbranchcircuitovercurrentprotectioninaccordancewiththeNational
ElectricCode,ANSI/NFPA70.(For1KVAand2KVAmodels)
CAUTIONToreducetheriskoffire,connectonlytoacircuit
providedwith30amperes
maximumbranchcircuitovercurrentprotectioninaccordancewiththenat ional
electriccode,ANSI/NFPA70.(For3KVAmodel)
CAUTION‐TodisconnectloadsfromtheUPS,pleaseinstallasuitableexternalpowerswitchor
breakerbetweenUPSoutputandloads.
ROCPOWER
PRESTIGE‐ usermanual
5
CHAPTER1
FrontDisplayPanelExplanation
ROCPOWER
PRESTIGE‐ usermanual
6
1. MainSwitch ThisiscontroltheON/OFFoftheUPS
2. SelfTestOKLED GreenLEDlightsupifselftestisO.K.
3. Test/Silence a.Tosilencealarmbypressingthebutton.
b.1.ForStandardUnit
ToexecutetheselftestoftheUPSbypressingthe
buttonover10sec.
b.2.ForUnitwithManualBypassfunction
(Specialmodel)
Topressthebuttonover5seconds,theUPSwillbe
switchedto
BypassModeandviceversa.
c.ToillustratethepercentageofoutputloadlevelatAC
Mode,andthebatteryenergylevelatBackupModeby
pressingthebutton.
4. FaultLED RedLEDlightsupifUPSisfaulty.
5. BypassLED AmberLEDlightsupwhenUPSisinBypassMode.
6. UtilityLED a.ACnormal:GreenLEDlightsup.
b.100%forload&batterylevel
7. InverterLED a.InverterOn:GreenLEDlightsup
b.75%forload&batterylevel.
8. BatterylowLED a.Batterylow:RedLEDlightsup
b.50%forload&batterylevel
9. OverloadLED a.Overloadcondition:RedLEDlightsup
b.25%forload&batterylevel.
ROCPOWER
PRESTIGE‐ usermanual
7
RearPanelExplanation
120V
5
7
1
2
3
4
4
7
1
2
5
3
4
7
1
5
3
2
1KVa 2KVa 3KVa
86
86
86
ROCPOWER
PRESTIGE‐ usermanual
8
1) ACInlet ThisistobeconnectedwithanACpowercordforpluggingin to
thewallreceptacle.
Thisistodisconnectlineinputtoprotectapplicationfrom
Outputoverloadorshortcircuit.
Fuse/BreakerRatingfor120Vac/230Vacsystems
1KVA 2KVA 3KVA
2) ACInput
Fuse/
Breaker
120Vac:20A/250V
230Vac:10A/250V
120Vac:25A/250V
230Vac:20A/250V
120Vac:50A/250V
230Vac:25A/250V
3) External
Battery
Terminal
Thisisabatteryterminaltobeconnectedwithadditionalbattery
banksforlongerbackuptimepurpose.Onlyaqualifiedtechnician
ispermittedtoprocesstheinstallation.
ThisistobepluggedbythedevicesbeingprotectedbytheUPS.
Sockettype 1KVA 2KVA 3KVA
NEMA
515R
4pcs 4pcs 6pcs
4) ACOutlet
For120Vac
System
NEMA
520R
N/A 2pcs 2pcs
5) SNMPSlot It is an optional feature used for SNMP card. Please Refer to
Chapter3.5forhardwareinstallation.
6) ComPort Thisisaninterfacetosendsignalstoandreceivesignalsfromthe
computer.Optionalcomputersoftwaremayberequired.Please
refertoChapter2.3foritspinassignments.
7)
RJ11/RJ45
Jack
This is to offer you a modem/internet (RJ11) and 10Base T
Network(RJ45)protectionagainstlineinterference.
8) DIPSwitches
ForCalibration.
CommunicationPortExplanation
ThecommunicationportontherearpaneloftheUPSisatrueRS232serialtype.Itmay
beconnectedtoacomputerandallowsthecomputertomonitorthestatusof UPS.It
alsocontrolstheoperationoftheUPSviaadditionalUPSsoftwarekits.Thebundled
softwareisfortheWindowsenvironment,suchasWindows95&98,WindowsNT,XP
andVista.Forotherapplications,suchasNovellNetWare,Unix/Linux,
etc.,pleasecontactyourlocaldistributorforapropersolution.
TheRS232InterfaceSettings
TheRS232interfaceshallbesetasfollows:
BaudRate
:2400bps
DataLength :8bits
StopBit :1bit
ROCPOWER
PRESTIGE‐ usermanual
9
Parity :None
ThePinAssignmentsoftrueRS232type
ThePinAssignmentsoftrueRS232typeareillustratedasfollows:
1
2
3
4
5
6
7
8
9
Pin6:RS232Rx
Pin9:RS232Tx
Pin7:Ground
ROCPOWER
PRESTIGE‐ usermanual
10
CHAPTER2
Checktheunitinitspackingcontainerandafter removal,butbeforeinstallation,forany
obviousproblems.Retainthepackingmaterialforfutureuse.
Unpacking
CAUTION:PleasebecarefulwhenliftingtheshippingcontainerortheUPS.Theseitemsare
heavy.Improperliftingormovementmaycausepersonal
injuriesorpropertydamage.
TaketheUPSoutofthepackingmaterial.Retainitforfutureuse.
InspecttheUPSforanyobviousdamage.Ifdamageexits,IMMEDIATELYcontactthehipper.
StandardPackageincludes:
‐User'sManual
‐ACInputPowerCord(Notavailableforhardwiringconnectionmodels)
‐IECoutputcables(fortheUPSwithIECsocketsonly)
‐RJ11PhoneJackCable
‐UPScommunicationkit(optional)
InstallationLocation
Itisnecessarytoselectaproperenvironmenttoinstalltheunit,inordertominimizethe
possibilityofdamagetotheUPSandextendthelifeofthe
UPS.Pleasefollowtheinstructions
below:
1. Keepatleast20cm(8inches)clearancefromtherearpanelof
theUPStothewall.
2. Donotblocktheairflowtotheventilationopeningsofthe
unit.
3. Pleasechecktheinstallationsitetoavoidoverheatand
excessivemoisture.
4.DonotplacetheUPSinanenvironmentneardusty,corruptive
orsaltymaterialorflammableobjects.
5. DonotexposetheUPStooutdoors.
ROCPOWER
PRESTIGE‐ usermanual
11
StorageInstructions
Forextendedstoragethroughmoderateclimate(15to+30°C/+5to+86°F),thebatteries
shouldbechargedfor12hourseverysix(6)monthsbypluggingtheUPSpowercordintothewall
outlet.Repeatthiseverythree(3)monthsinahightemperature(+30
to+45°C/+86to+113°F)
environment.
ROCPOWER
PRESTIGE‐ usermanual
12
CHAPTER3
Setup
OperationTestandInstallationInstruction
Theinstallationshouldbeconductedorsupervisedbyaqualifiedtechniciantoavoidaccident.
ChargetheUPSformorethan8hoursafterunpacking toensuretheUPSisfullychargedbefore
usage.
1.Ensurethatthewalloutletisproperlygrounded.
2.Verifyifthevoltageandfrequencyratingsmatchthatof
theutility,thenconnecttheACInputpowercordtoa
verifiedgrounded3wirereceptacle.
3.TurnontheMainswitchonthefrontpaneltostartthe
UPS.Thefanontherearpanelwillspin.
4. After7~10seconds,thestartupofUPSwillbecompleted,
thentheutilityLEDandinverterLEDlightup
simultaneously.
5.DisconnecttheinputpowercordoftheUPStosee
whethertheUPSremainsoperationalwhentheutilityis
abnormal.
6.Reconnecttheinputpower
cordoftheUPStowalloutlet,thenconnectthepowercord
ofyourdevicetotheoutputreceptacleoftheUPS.
7.TurnontheMainswitchonthefrontpanel.TheutilityLEDandinverterLEDwilllightup
in7~10seconds,thenturnontheswitchof
thedeviceconnectedtoit.Donotexecute
anycriticalapplicationyet!
8.DisconnecttheUPSfromthewalloutlettosimulateutilityfailure.TheutilityLEDshould
extinguishandthealarmwillsoundcontinuouslyuntilbatterycutoff.Thedevice
connectedtotheUPSshouldoperatecontinuously.Tomutethe
audiblealarm,please
pushtheTest/SilenceButtononthefrontpanel.
9.Yourinstallationisdonesuccessfully.
ROCPOWER
PRESTIGE‐ usermanual
13
CHAPTER4
ProductIntroduction
Doubleconversionsonlinearchitecturecontinuouslysupplyyourcriticaldevicewithahigh
performance,stable,regulated,transientfreepuresinewaveACPower.
Fullprotectionforoverloading,shortcircuitandoverheating.
Powerfulmicrocomputerintegrateddesignprovidesbettersmartfunctionsandcontrol.
AdvancedInputPFCcontrol
guaranteesthePFperformanceandmaximumenergy
efficiency.Thewideinputvoltageworkingrangeminimizesbat teryusag eandenhances
batteryutilizationandlife.
DCstartfunctionensuresthestartupofUPSduring poweroutages.
SNMPadapterslotrepresentstheadvancedupgradesolutionindirectpowermanagement
viaInternet.
SNMPSlot
YoumayinstalltheSNMPcardintotheSNMPslotontherearpaneloftheUPS.TheUPS
maybeconnectedtothenetworkmanagementsystemviatheSNMPcard.
Theinstallationshouldbeperformedbyaqualifiedtechnicianauthorizedbyyourlocal
distributor.
InserttheSNMPcardintotheSNMPslotasshown.
Connectthenetworkcablefromthenetworkdevice(ex.
Hub)withSNMPaccessibilitytotheUPS.SettheSNMPcard
toConfigurationModeandconfiguretheSNMPcard.
(PleaserefertotheSNMPUserManualforconfiguration
instructions.)
Yourhardwareinstallationisnowcompleted.
ROCPOWER
PRESTIGE‐ usermanual
14
CHAPTER5
HowtheUPSWorks
WhenUtilityisNormalFigure1
Whentheutilityisnormal,theutilityLEDlightsupandthe
batteriesarebeingcharged.IftheinverterwasturnedON,
andtheoutputisnormal,theinverterLEDwillalsolightup.
UtilityFailureandRecovery
Figures2and3
Whentheutilityisabnormal,theutilityLEDwilldimandthe
batterieswillstopcharging.IftheinverterwasturnedON,
theUPSwillconvertbatterypowerfortheoutputandthe
inverterLEDwillremainlit.IftheinverterwasturnedOFF,
the
UPSwillshutOFFcompletely.Figure2
Whentheutilityisbacktonormal,theUPSwillreturnto
Figure1.
Whentheutilityfails,thebatterieswilldraingradually.
Whenthebatteryenergyislow,the“Bat.Low”LEDwilllight
upandthebuzzerwillbeeptwicea
secondbeforetheUPS
shutsOFF.TheUPSwillrestartautomaticallywhenthe
utilityisbacktonormal.Figure3
Fig1
Fig 2
Fig 3
ROCPOWER
PRESTIGE‐ usermanual
15
OverloadConditionFigure4
Whentheutilityisnormal,theloadingoftheUPSabove105%
isconsideredan overloadandthe“Overload”LEDwilllightup.
IftheUPSoverloadisbetween105~120%,itwillswitchto
BypassModewithin60seconds.IftheUPSoverloadis
between
120%150%,itwillswitchtoBypassModein10
seconds.IftheUPSoverloadisover150%,itwillswitchto
BypassModeimmediately.WheninBypassMode,theutility
LED,bypassLEDandoverloadLEDlightup.Whentheoverload
conditioniseliminatedbyreducingtheloadunder90%,
the
UPSwillautomatically switchbacktoNormalMode.InBattery
Mode,theoverloadwillshutOFFtheUPSoutput.
AbnormalOutputConditionFigure5
OutputshortcircuitunderInverterMode
IftheoutputloadisshortcircuitedunderInverterMode,the
UPSwillturnOFFthe
outputtopreventdamagetotheload.
ThefaultLEDlightsupandthebuzzerhasalongbeep.TheUPS
willlocktheoutputandyouwillberequiredtomanuallyrestart
theUPSaftertheshortcircuitiseliminated.TorestarttheUPS,
pushtheMainswitchonthe
frontpaneltotheOFFposition,
thentotheONposition.
OutputshortcircuitunderBypassMode
IftheoutputloadisshortcircuitedunderBypassMode,the
inputACfusewilltripopentopreventdamagetotheoutput
load.Useanewfusewithsameratingafterthe
shortcircuitis
eliminated.Ensurethatshortcircuithasbeeneliminated
beforerestartingtheUPS.
Fig 4
Fig 5
ROCPOWER
PRESTIGE‐ usermanual
16
Overheating
IftheUPSoverheatswhentheutilityisnormal,itwillswitchto
BypassMode.ThefaultLEDandbypassLEDwilllightupandthe
UPSwillswitchtoInverterModeaftertheoverheatingis
eliminated.Ifithappenswhentheutilityisabnormal,the
buzzerwillbeep
continuouslyandthefaultLEDwilllightup.
TheoutputoftheUPSwillalsobeshutOFF.
InverterOvercurrentorOutputVoltageAbnormalFigure6
Ifexcessiveinvertercurrentoroutofrangevoltageisdetected
bytheUPS,itwillswitchtoBypassModewhenthe
utilityis
normal.TheutilityLED,bypassLEDandfaultLEDwilllightup.
Ifthesetwoconditionsoccurwhentheutilityisabnormal,the
UPSwillturnOFFtheoutputandthefaultLEDwilllightup.
Fig 6
ROCPOWER
PRESTIGE‐ usermanual
17
CHAPTER6
Troubleshooting
WhentheUPSmalfunctionsduringoperation,youmaycheckthelistbelowforproper
adjustment.Shouldtheproblempersist,pleasecontactyourlocaldistributorforhelp.
Situation CheckItems Solution
UtilityLEDisnotONandthe
UPSisonBatteryMode,
whentheutilityisnormal.
ACinputcordislooseor
ACinputfuseisbroken.
1.ConnecttheACinputcord
towallreceptacle.
2.ReplacetheACfusewith
oneofthesamerating.
3.Ifproblem
persists,please
callforservice.
TheUPSswitchestoBattery
ModethenbacktoUtility
Mode,whentheconnected
deviceisturnedON.Or,the
UPSswitchesbackandforth
betweenbatteryandutility.
1.Checkifanypowerstrip
isconnectedtothe
UPS.
2.Checkfordamagetothe
wallreceptacle.
1.Donot
usepowerstrip.
2.Replacethewallreceptacle.
OverloadLEDlightsup
UPSisoverloaded.Please
removesomeloadatthe
outputendoftheUPSuntil
theREDLEDextinguishes.
ROCPOWER
PRESTIGE‐ usermanual
18
Situation CheckItems Solution
BatteryLowLEDlightsup
Batteryisrunningout.Please
proceedtoimmediately
shutdownyourloadand
applications,thenrecharge
thebatteries.
FaultLEDlightsup
Disconnecttheoutputload
immediatelyandturnonthe
UPStoseeifthefaultLEDis
stillon.Ifnot,youroutput
loadhasprobablybeen
shorted.Otherwise,callfor
service.
Systemfailstobackupwhen
theutilityfails.
Disconnecttheinputpower
cordfromtherearpaneland
turnonthefrontswitchtosee
iftheUPSturnson.Ifnot,call
forservice.
UPSisnormalbutnooutput
toload
Checktoseeifallcords
areproperlyconnected.
Checkalloutletstoseeifthey
areproperlyconnected.
Strangenoiseandsmell
Immediatelyshutdownthe
wholesystem.Disconnectthe
powerfromtheUPSandcall
forservice.
Maintenance
Cleanthedustfromtheventilationopeningsandintakesontherearpanel.
1. TurnOFFtheUPSandwipethecasingwithadampcloth.
2. PeriodicallyunplugthepowercordoftheUPSfromthewalloutlettotestthe
conditionofthebatteries.
3. Ensurethatall
applicationshavebeensavedbeforethebatterydischargingcapability
testisconducted.
ROCPOWER
PRESTIGE‐ usermanual
19
CHAPTER7
Communication
HardwareInstallation
1.ConnectthemaleconnectorofRS232cabletotheUPScommunicationport.
2.ConnectthefemaleconnectorofRS232cabletoadedicatedRS232port.Ifthereis
onlyaDB25connectoronyourPC,useaDB9DB25adaptertoconvertit.
SoftwareInstallation
PleaserefertothedocumentscontainedinthesoftwareCDROM .
ROCPOWER
PRESTIGE‐ usermanual
20
CHAPTER8
Specifications
MODEL 1KVA 2KVA 3KVA
INPUT
Voltage(Vac) 80~140or160~280
Frequency(Hz) 50/60±5%(AutoSensing)
Phase Single
InputPowerFactor >0.98(FullLoad)
OUTPUT
Voltage(Vac) 100/110/115/120or200/220/230/240
Capacity(VA/W) 1000/700 2000/1400 3000/2100
WaveForm SineWave,THD<3%(noloadtofullload)
VoltageRegulation ±2%
FrequencyStability ±0.5Hz(FreeRunning)
TransientResponse
(ms)
+/4%Underfullloadchangeandcorrectedwithin60ms
Synchronization
1Hz/Sec.SlewRate:InverterFreeRunningIfInputFrequency
Over±5%Range
CrestFactor 3:1
TransferTime
(LineFault)
0ms
Efficiency(ACtoAC) >83%
RunTime(FullLoad) 8Min. 7Min. 8Min.
DCStart Yes
BATTERY
Type SealedMaintenanceFreeLeadAcid
Quantity(pcs) 3 6 8
Voltage(Vdc) 36 72 96
RechargeTime 8HoursTo90%
Supplementary
Charger(Optional)
200/500WCharger,forextendedbackupapplication.
DISPLAY
LED
Utility,BatteryLow,Inverter,Bypass,SelfTest,Load
Level,BatteryLevel,Overload,FaultConditions
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32

Rocstor Prestige Specification

Category
Uninterruptible power supplies (UPSs)
Type
Specification

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI