Schick Handel DMR18 User manual

  • Hello! I am an AI chatbot trained to assist you with the Schick Handel DMR18 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
DMR18
User Manual
Door Station
Please read this manual carefully before using the product you purchase, and keep it well for future
use.We reserve the right to modify the specication in this manual at any time without notice.
1 2 3
654
7 8 9
#0
*
RF CARD
1.Parts and Functions
2. Terminal Descriptions
Camera Lens
Night View LED
Speaker
Adjustable Camera
Connectiong Port
With rainy cover
350 mm
128 mm
1 2 3
654
7 8 9
#0
*
RF CARD
LCD Screen
ID Card Window
Digital Keypad
Microphone
12
3
L1
T/R -
CN-LK
T/R+
J/KMB JP-LK
Bus
SD Card Slot
EB+
EB-
N.O
LK+
LK-
+12V
L2
1 2 3
654
7 8 9
#0
*
RF CARD
12
3
12
3
•
+12V:
12VDCpoweroutput.
•
LK-(GND):
powerground.
•
LK+(COM):
commoncontactoftheRelay.
•
NO.:
normallyopencontactoftheRelay(refertoDTtechnicalguideforLockconnection
detailinformations).
•
EB+:
Exitbuttonconnectionport.
•
EB-:
Exitbutonconnectionport.
•
JP-LK:
Forelectroniclocksafetytypesetting(refertoDoorStationLockConnections).
•
T/R-:
USB-RS485communicationterminalnegative.
•
T/R+:
USB-RS485communicationterninalpositive.
•
Bus(
L1,L2
):
non-polaritybusline.
3.Door Station Mounting
1 2 3
4
7
5 6
Drill a hole and attach the
rainy cover to it
Attach screws to fix the
metal box
Attach the unit to the rainy
cover correctlly
Attach the baffle to protect
the unit from droping
The last view for all mounting
The view for rainy
cover after mounted
Adjust the camera angle and attach the
metal to the panel and wire correctly.
Camera
angle
4. Door Lock Connections
1. Internal Power Supply Mode
Use the powerofthesystemto supplyfortheelectroniclock,so thatthelockcanbe
connectedtothedoorstationdirectly,withoutanadditionalpowersupplyfortheelectroniclock.
Notethatthedoorstationcanonlyoutput12Vdcpower,thereforethekindoflockislimited.
• Theratedpowerofthelockmustbelessthan12Vdc300mAwhenusinginternalpower
supplymode
• TheGNDmustconnecttothenegativeofthelock,andtheCOMconnecttothepositive.
• Jumpersetto1-2positionforPower-to-Unlocksafetytype(Normally open mode);set
to2-3positionforPower-off-to-Unlocktype(Normally closed mode).Notethatthe
unlockrelaymodeissetontheParametertabofDTCONFIGsoftware.
• Ifdifferentunlockingtimeisneededtobeconfigured,theDTCONFIGsoftwarecanbe
usedtochangetheUnlock TimingontheParametertab(seetheprogramsection).
JP_LK
12V 300mA
Jumper set to 1-2 position
+
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
1
2
3
set to Normally open on the
Unlock Relay mode on DT-config
software.
A. Connection for Power-to-Unlock type:
12V 300mA
Jumper set to 2-3 position
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
+
-
set to Normally Closed on the
Unlock Relay mode on DT-config
software.
JP_LK
1
2
3
B. Connection for Power--off-to-Unlock type:
+
+
-
-
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Open on the
Unlock Relay mode on DT-config
software.(default)
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
+12V
LK - (GND)
LK+(COM)
N.O.
EB+
EB -
Remove the Jumper
set to Normally Closed on the
Unlock Relay mode on DT-config
software.
+
+
-
-
JP_LK
1
2
3
Note: Cut off this line when
using external power supply
2. External Power Supply Mode
Whentheelectroniclockisover12Vdc,additionalpowersupplyforthelockisneeded.
• Thepowersupplyforthelockmustbelessthan48Vdc1.5A.
• TheJumpermustberemovedwhenusingexternalpowersupply.Thedefaultsettingis
Power-to-Unlocktype(Normally open mode),ifusePower-off-to-Unlocktype,change
theUnlockRelaymodetoNormally closed mode.Notethattheunlockrelaymodeis
setontheParametertabofDTCONFIGsoftware.
• If differentunlockingtimeisneededtobeconfigured,pleaseusetheDTCONFIG
softwaretochangethesettingontheParametertab(seetheprogramsection).
C. Connection for Power-to-Unlock type:
D. Connection for Power--off-to-Unlock type:
5. Door Station Congurations
1. About room code(address):
RoomCode(alsocalledroomaddress)isacodeassignedtoeachmonitor,toidentifydifferent
monitors;eachmonitorhaveauniqueroomcodeinonebuidling.TheroomCodeisstoredin
eachMonitor’sinnerEEPROMmemory,anddoesnotloseeventhemonitorispoweroff.
2. About Debug State:
TheDebugStateisyourstartingpointforusingalltheapplicationsonDMR18.
WhenDoorStationisin
standby,press'#'key
Press"2#"keytoexitoutthedebugstate.
input'9008',theninputthe
AdminCode.(66666666by
default)
DebugStatemenuislaunched
[ 9 0 0 8 ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
> > D e b u g S t a t e < <
1 - # To o l s
0 - # R e d i a l
2 - # E x i t s
3. About Debug Tools:
DuringworkingatDebugState,press"1#"toentertoolspage,DebugToolsoverviewsis
shownasbelow:
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
1 - # To o l s
Item Submenu
1. Installer Setup
1.IDCode[1]
2.UnlockTiming[05]
3.UnlockOutput[0]
4.CardMemory[0]
5.DoorplateMode
6.AudioOptions...
7.Parameters...
8.InstallerCode...
9.Default...
2. Setup
1.Language[1]
2.ToneSelect[03]
3.ToneVolume[08]
4.UnlockCode[1111]
5.DisplayMode
6.Clock...
7.SetupCode...
8.About...
9.Default...
3. Card Manage
1.AddCard...
2.DeleteByCard
3.DeleteByM.code
4.CardsInformation
5.Format
4. Online Monitors
Tosearchtheonlinemonitors,inputthemonitorcode
numbertosearch
5. Online Devices
Tosearchtheonlinedoorstations.Max.4doorstation
canbesearched
6. Voltage Measure
Tocheckthe voltageof the monitor,note that the
monitormustbeonline.
Table1:
Basic Tools Detail:
Item Description
Factory
set
IDCode
Ifonlyonedoorstationisinstalledinthisbuilding,set
to1;
Ifmultidoorstationsareinstalled,primarydoorstation
mustbesetto1,andotherslavedoorstationsmust
besetfrom2to4.Notethatmax.4doorstationsis
availableinonebuilding
[1]
Single
UnlockTiming
Tosetthetimethathowlongthedoorkeepsopen
whendoorisreleased.Rangefrom01to99seconds.
[05]
5seconds
UnlockOutput
Tosettheunlockmodetomatchthecorresponding
lock.Randfrom0to1
0
CardManage
Tosetthecardlocation.Ifsetto0,thecardissavedin
doorstation.Ifsetto1,thecardissavedinDT-IPC
0
DoorplateMode
Tosetthecallingmode.Ifsetto0,it'stheauto
mode,thatmeansthecallingwillbeactivateddirectly
afterinputting2digitscode.Ifsetto1,it'sthemanual
mode,thatmeansyoushouldpress"#"buttonto
activatethecallingafterinputtingthecode.
[0]
Automode
AudioOptions...
Tosetthetalkingmode.Ifsetto0,handsfreemodeis
activated.Ifsetto1,handsetmodeisactivated.
0
Parameters... Toshowtheparameters,pleaserefertotable2.1
InstallerCode... Tochangedoorstationadministratorcode [66666666]
Default...
Notethisoperationisirreversible.Oncerestoreis
activated,allparameterswillreturntofactorydefault
settingexcepttheinformationofaccesscard.
Table2(InstallerSetup):
Item Description
Factory
set
MonitorTiming Toshowthemonitortime,Rangefrom6sto600s 30s
SwitchTiming
ToshowthesurveillancetimeforeachDoorStationor
CCTVcamera.Rangefrom6sto600s
40s
WaitTiming Toshowthecallingwaittime,Rangfrom10sto600s 30s
TalkTiming
Toshowthelimitationtimeoftalking,Rangefrom10s
to600s
90s
Monitor&Speack
ToenableIndoorMonitorundermonitoringstatecan
speaktoDoorStationatsametime.Ifsetto1,talk
enabled;setto0,disabled.
Monitor&Unlock
ToenableMonitorsundermonitoringstatecanopen
thedooratthesametime.Ifsetto0,unlockfunction
isdisabled;Setto1,unlockisenable;Setto2,unlock
isenableandcloseatonce;Setto3,unlockisenable
andclosein5s.
[1]
RingNumbers
Toshowringtimeswhendoorstationcallsmonitor.4
optionsforchoice.Ifsetto0,ringonce.Ifsetto1,ring
twice.Ifsetto2,ringthreetimes.Ifsetto3,cyclering
[1]
NameListDisplay
Mode
Toshowthenamelistdisplaymode.Ifsetto0,it'sthe
DT-Configdisplaymode.Ifsetto1,it'stheSimulate
displaymode
[0]
WorkingMode
Toshowtheworkingmode.Ifsetto0,it'stheapartment
systemmode.Ifsetto1,it'sthevillamode.
[0]
Table2.1(Parameters):
Note:
thissectionissetonDT-Congsoftware,formoredetailinformations,pleaserefertothe
DT-Congsoftwareuserinstructions.
Item Description
Factory
set
Language
Tochangelanguage.thecodeformatis4digits.Pleaserefer
topart5,section10(changedoorstationlanguage)formore
detailinformations.
01
ToneSelect
SelectthechimeofDoorStationincallingwaitstate,12
chordtunesareavailable,keyin01to12toselect.
03
ToneVolume
Adjustthetonevolumefordooorstationincalling.Rangfrom
01~15
08
UnlockCode
TochangeunlockcodeinCommonCodeUnlockmode,in
4-digitsformat.1111isthedefaultunlockcode.
[1111]
DisplayMode
ToselecttheDoorStationscreenmenu.Ifsetto0,the
screendisplaysthevisitor'simagewhentalking.Ifsetto1,the
screendisplaysiconswhentalking.
[0]
Clock...
Tosetdateandtime.
Dateformat:ifsetto0,dateformatisDD/MM/YY,ifsetto
1,dateformatisMM/DD/YY.
Timeformat:ifsetto0,timeformatis24hourstandard.Ifset
to1,timeformatis12hourstandard.
SetupCode TochangetheProgramCode. [88888888]
About...
1.Hardwareversion---ToshowtheDoorStation(including
ACS)hardwareinformation
2.Softwareversion---ToshowtheDoorStation(including
ACS)softwareinformation
3.ManufactureDate---Toshowthemanufacturingdate
4.DialingCounts---Toshowthecalloperationcounts
5.CallsCounts---Toshowtheestablishedcallingcounts
6.UnlockCounts---Toshowtheunlockoperationcounts
7.StandbyVoltage---Toshowthevoltagethatthedoor
stationinstandby.
8.WorkingVoltage---Toshowthevoltagethatthedoor
stationinworking.
9.VideoStandard---PALorNTSCstandard
10.UI_CODE---ToshowtheUIbytecountsandcheckbox
11.MCM-VER---ToshowtheversionandlanguageforMCM
12.Updated---ToshowtheupdatedtimeforUI
Default...
RestoreallSetupparameterstofactorydefaultsetting,Please
notethatthisoperationisanirreversible
Table3(Setup):
Item Description
Factory
set
AddCard... Toaddtheusercard
DeleteByCard Todeletecardbyusercard
DeleteByM.code Todeletecardbyroomcode
CardsInformation Toshowtheinformationsaboutcards
Format Toformatinformationsaboutcards
Table4(CardMemory):
4. Calling and Unlock Operation:
TheDMR18doorstationisadigitalstationwith320*240pixelsLCDscreen,colorCCD
camera,nightviewLED,anddigitalkeypad.
VisitorscancalltheapartmentbydialingtheFlatCode(apartmentnumber)onthekeypad.
Iftheydon’tknowtheFlatCode(apartmentnumber),theycansearchthenamelistonthe
screen.Ifthedoorstationisinstandby,visitorsneedtopress'9#'todisplaytheusernamelist.
Press"#"keytoscrollnext/lastpage.andusekey1to8keyoneachpagetocallthedesired
at.
ResidentscanopenthedoorbyusingtheiruniqueUnlockCode(four-digitPINcode).Ifthe
doorstationisinstandbymode,press'#'key,theninputthefour-digitunlocktoopenthedoor.
Pleaserefertopart5,section7(Howtousecodeunlockfunction)formoredetailinformation.
5. About Default Set:
TheDefaultSetisveryimportant.Whenthedoorstationmissupthesettingsinanyway,
themostquicklyandeasywaytosolvetheproblemistoactivatethedefaultsettingondoor
station.Thedefaultsettingsalreadyhavealltherightsettingsforone-buildingsystem,that
meansthesystemwillworknormallywithoutanyadditionalsettings..
Note:
Ifthedoorstationworksasapartmentsystemmode,input01~32tocalltherelevant
monitor.Ifthedoorstationworksasvillamode,input01tocallthemonitorswhichitscodeis
from00~15.Input02tocallthemonitorswhichitscodeisfrom16~31.pleaserefertotable
2.1(workingmode)
InDebugState,press'1#'
key
InToolsmenu,press'1'
key
InputInstallercode(66666666
bydefault),thenpress"#"tosave
Press'9'key,a
passwordwillbeasked.
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
1 . I D C o d e . [ 1 ]
2 . U n l o c k T i m i n g [ 0 5 ]
3 . U n l o c k O u t p u t [ 0 ]
4 . C a r d M e m o r y [ 0 ]
5 . D o o r p l a t e M o d e
6 . A u d i o O p t i o n s . . .
7 . P a r a m e t e r s . . .
8 . I n s t a l l e r C o d e . . .
Press No.
to select
*Back
Installer
Setup
9 . D e f a u l t
1 - # To o l s
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
*Back
[ - - - - - - - - ]
Please Input Password
# Save
9 . D e f a u l t . . .
Press“#”,Input“8002”,then
inputSetupCodeorAdmin
Code(88888888or66666666by
default)
Press“2”toentertone
selectitem.
6. Change Ring Tone:
Thereare12differentringtones,IfdoorstationrunsasDebugState,youcanpress[1#]-->
[2]Setup-->[2]ToneSelecttoentertonesettingpage.IfitrunsasNormalState,followthese
steps:
Input2digitsnumber,
thenpress“#”tosave
thesetting
[ 8002 ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
1 . L a n g u a g e [ 1 ]
3 . To n e V o l u m e [ 0 3 ]
4 . U n l o c k C o d e [ 1 1 1 1 ]
5 . D i s p l a y M o d e
6 . C l o c k
7 . S e t u p C o d e
8 . A b o u t
9 . D e f a u l t
Press No.
to select
*Back
Setup
*Back
[ - - ]
( 01~12)
# Save
2 . To n e S e l e c t [ 0 3 ]
2 . To n e S e l e c t [ 0 3 ]
7. Change Installer Code(administrator password):
TheInstallerCodeisthepasswordtoaccessthedoorstationdebugState.Thedefault
InstallerCodeis'66666666'.NotethatiftheDefaultSethavebeenactivated,theInstallerCode
willbesettodefaultvalue.
8. How to use code unlock function:
Pleaserefertothefollowingoperations:
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
1 . I D C o d e [ 1 ]
2 . U n l o c k T i m i n g [ 0 5 ]
3 . U n l o c k O u t p u t [ 0 ]
4 . C a r d M e m o r y [ 0 ]
5 . D o o r p l a t e M o d e
6 . A u d i o O p t i o n s . . .
7 . P a r a m e t e r s . . .
9 . D e f a u l t
Press1~9
to select
*Back
Installer
Setup
1 - # To o l s
8 . I n s t a l l e r C o d e . . .
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
*Back
[ - - - - - - - - ]
( * * * * * * * *)
# Save
8 . I n s t a l l e r C o d e . . .
InDebugState,press'1#'
key
InputanewInstallerCodeand
thenpress'#'keytoconrm
press'1' press'8'
[ - - - - ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
1 2 3
654
7 8 9
#0
*
RF CARD
[8017 ]
i
Door Open
WhentheDoorStationisin
standby,Press“#”
Ifveriedcorrectly,
dooropen
Input4digitsUnlockCode
directly
Press“#”,Input“8002”,
theninputSetupCodeor
AdminCode(88888888or
66666666bydefault)
Press“4”toenterunlock
codeitem.
9. Change Unlcok Code:
IfdoorstationrunsasDebugState,youcanpress“1#”toactivateToolsMenu,thenselect“2”
toentersetuppage,thenselect4item.IfitrunsasNormalState,followthesesteps:
[ 8002 ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
1 . L a n g u a g e [ 1 ]
2 . To n e S e l e c t [ 0 3 ]
3 . To n e V o l u m e [ 0 3 ]
5 . D i s p l a y M o d e
6 . C l o c k
7 . S e t u p C o d e
8 . A b o u t
9 . D e f a u l t
Press No.
to select
*Back
Setup
*Back
[ - - - - ]
( * * * *)
# Save
4 . U n l o c k C o d e [ 1 1 1 1 ]
4 . U n l o c k C o d e [ 1 1 1 1 ]
Input4digitsnumber,
thenpress“#”toupdate
10. User Card Management:
ThissectionexplainshowtocongurethekeyfobfunctiononDMR18,Thekeyfobisusedto
openthelock.Total1000keyfobscanberegisteredwithonedoorstation.Whenswipingthe
fobtothedoorstation,thedistancemustbelessthan3centimeter.
KeyFobsmustberegisteredontheDoorstationthatcanbeusedtoopenthedoor.
Register the Key Fobs:
AlltheregisteredkeyfobsarecalledUserCards/UserKeyFobs.Newfobs/cardsneedto
beregisteredonebyonetotheDoorstationtobecomeavalidUserCard/UserKeyFob;and
everyUserCard/UserKeyFobisrelatedtoacertainMonitorAddress(Flatcode).
WhentheDoorstationisstandby,press[#]-->[9008]-->Password([66666666bydefault])
togetintotheDebugModeMenu,thenPress[1#]-->[3]CardManage-->[1]AddCardtoget
intotheAddCardpage.Pleaseseethefollowings.
EnterAddCardmenu,and
RoomCodeisasked.
InputRoomCode Readthecardtobe
authorized
Delete user cards:
Delete By Card:
InDebugState,Press[1#]-->
[3]CardManage-->[2]Delete
ByCardtoenterDeletebyCard
page.as shown on the right,
thenshowthecardsyouwantto
deleteonebyone.
2 . D e l e t e B y C a r d . . .
* Back # Save
Show The Card
2 . D e l e t e B y C a r d . . .
* Back # Save
U
s
e
r
C
a
r
d
C a r d numbs:
1 5 9 7 7 1 3 1
Show The Card
RegisteredUserCards/KeyFobscanbedeletedfromtheDoorstation,oncedoingthedelete
operation,thecard/keyfobscannotopenthedooranymore.Theycanalsobere-registered
againtobecomeavalidUserCard/UserKeyFob.TherearetwowaystodeleteUserCards/
UserKeyFobs:
1.Deletebycard:showtheunwantedcard(s)whentheDoorstationisinDeleteCardMode
2.Deletebyroomnumber:deletealltheregisteredUserCardsrelatedtothatroomnumber.
1 . A d d C a r d . . .
* Back # Save
Please Input Room Code
[ - - ]
1 . A d d C a r d . . .
* Back # Save
Show the card
[ 0 1 ]
1 . A d d C a r d . . .
* Back # Save
[ 0 1 ]
C a r d numbs :
1 5 9 7 7 1 3 1
Show The Card
U
s
e
r
C
a
r
d
3 . D e l e t e B y M . c o d e
* Back # Save
Please Input Room Code
[ - - ]
3 . D e l e t e B y M . c o d e
* Back # Save
U pd a t e d
[ 0 1 ]
InDebugState,Press[1#]-->
[3]CardManage-->[3]Delete
ByM.Code toenter Deleteby
M.Code page.as shown on
theright,thenInputtheRoom
Code,press#toconfirm; all
associatedcardswillbedeleted.
Delete by Room Number:
Card information:
Format:
EnterCardInformationpage,andthe
screenwilldisplaytheauthorizedUser
Cards count, and card read access
eventscount.
EnterCardFormatpage,apassword
will be asked,input 8digits installer
password(66666666bydefault),then
press"#"keytosave,formatoperation
isactivated.allcardinformationwillbe
cleared.
4 . C a r d s I n f o r m a t i o n
* Back # Save
Card Count: 1000
5 . F o r m a t
* Back # Save
Please Input Password
[ - - - - - - - - ]
11. Change Door Station Language:
It'sconvenienttochangetheuserinterfaceforDMR18.JustputtheconglestotheSDcard
andbymeansofthedigitalkeypadofdoorstation,only30secondsisneededtoupdate.
L1
T/R -
CN-LK
T/R+
J/KMB JP-LK
Bus
Insert SD card
SD Card Slot
EB+
EB-
N.O
LK+
LK-
+12V
L2
12
3
12
3
Step 1: Insert the SD card which is
containedconglesintotheSDcardslot
whereisatthebackofthedoorstation.
Refertotherightdiagram.
Step2:
IfdoorstationrunsasDebugState,youcanpress“1#”toactivateToolsMenu,select“2”to
entersetuppage,thenselect1item.IfitrunsasNormalState,followthesesteps:
Language code number:
[8017 ]
i
Download
[ 8002 ]
Please Input Password
1 2 3
654
7 8 9
#0
*
RF CARD
2 . To n e S e l e c t [ 0 3 ]
3 . To n e V o l u m e [ 0 3 ]
5 . D i s p l a y M o d e
6 . C l o c k
7 . S e t u p C o d e
8 . A b o u t
9 . D e f a u l t
Press No.
to select
*Back
Setup
*Back
[ - - - - ]
( Code Number)
# Save
1 . L a n g u a g e
4 . U n l o c k C o d e [ 1 1 1 1 ]
1 . L a n g u a g e [ 1 ]
Press“#”,Input“8002”,then
inputSetupCodeorAdmin
Code
Press1
Input4digitscodenumber,
Refertothetable.
Whenthedoorstationoutput
alongsoundDI...,thatmeans
UIupdatingisnished.
8101: English
8102: French
8103: Spanish
8104: Italian
8105: German
8106: Dutch
8107: Portuguese
8108: S-Chinese
8109: T-Chinese
8110: Greek
8111: Turkish
8112: Polish
8113: Russian
8114: Slovakia
8115: Hungray
8116: Czech
12. Search online door stations and monitors:
OnlineSearchisaveryusefulfunctionthatcanhelptheinstallertoeasilycheckthe
connectivityofalltheMonitors.Pleasenote,Onlinedoesnotmeanviatheinternet.Please
refertothefollowings:
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
* Back # Save
[DS1 ] : Online
[DS2 ] : Fail
[DS3 ] : Fail
[DS4 ] : Fail
5 . O n l i n e D e v i c e s
1 - # To o l s
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
InDebugState,press'1#'
key
Press'5'key Checkdoorstations
connectionstatus
Check online door stations:
> > D e b u g S t a t e < <
0 - # R e d i a l
2 - # E x i t s
* Back # Save
(Search Range)
[ - - ] ~ [ - - ]
4 . O n l i n e M o n i t o r s
* Back # Save
[ 01 ] Online
[ 02 ] Online
[ 03 ] Online
[ 04 ] Fall
[ 05 ] Online
4 # . O n l i n e M o n i t o r s
1 - # To o l s
1 . I n s t a l l e r S e t u p
2 . S e t u p
3 . C a r d M e m o r y
4 . O n l i n e M o n i t o r s
5 . O n l i n e D e v i c e s
6 . V o l t a g e M e a s u r e
Pres NO.
to select
*Back
Tools
InDebugState,press'1#'
key
Press'4'key Input2digits
monitorcode
SearchRange:inputthemonitoradress.Forexample,
inputtherangefrom01to05.Youwillseetheconnection
statusoftheselectedmoinitors.
13. Namelist function:
DMR18isdesignedtohavedigitalkeypadandbigTFTscreen.Itsnamelistwasshownon
thescreenandcustomercandothecallingoperationthroughthedigitalkeypadguidedby
Namelistonthescreen.2typesofnamelistcanbeshownonthescreen:DT-Congnamelist
andSimulatenamelist.
Enter namelist page:
Check online monitors:
Send namelist to monitors
Press'9#'instandbymodetodisplaytheusernamelist.Press"#"keytoscrollnext/lastpage.
andusekey1to8keyoneachpagetocalltheatyouwant.PleaserefertotheDT-Cong
softwreuserinstructionsforcongurethenamelist.
Thenamelistcanbesenttomonitorsbydoorstationdirectly.Connectthedoorstationand
montiorscorrectlytothesystem.Thenpress#8012instandbymode,andinputpassword
(66666666bydefault)tosendnamelisttoallthemonitors.
6. Specication
Power supply: DC24V(Powered by DT-DPS)
Camera Lens : 1/4 ACS 4T image sensor with DSP processor
Power consumption: Standby 3W;Working status 9W
Screen: 3.5 inch TFT
Resolution: 320(R, G, B)X240 pixels
Video signal: CCIR/EIA Optional
Wiring: 2 wires, non-polarit
DT-ENG-DMR18-V1 2011S0621
/