Skope 988E Operating instructions

Type
Operating instructions
988E
SKOPE Deluxe Bathroom Fan Heater
Operating Instructions
PRN0355 Rev. 2.0 March 2010
2988E
SKOPE Deluxe Bathroom Fan Heater
Introduction
Designed for easy installation, your SKOPE 988E Deluxe Bathroom
Fan Heater incorporates a unique wall-mounting hinged chassis,
making installation faster and easier. The heater also features an
installer adjustable step-down thermostat, which can be adjusted or by-
passed during installation.
Safety Information
When using any electrical appliance, safety precautions should always
be observed. Read these instructions carefully, and retain for future
reference. For service, contact your nearest authorised service agent.
Under no circumstances should an unauthorised person open the
heater, in order to adjust the thermostat.
When used by, or near, young children or infirm persons, close
supervision is necessary. Young children should be supervised to
ensure that they do not play with the appliance.
Do NOT use this appliance other than for its intended use.
Use this appliance with the voltage specified on the rating label.
Be very careful not to touch hot surfaces or moving parts.
Do NOT cover the grilles or place any object or material up against
the unit, as this may block entry or exhaust of airflow.
Do NOT probe any opening to remove fluff. To ensure trouble-free
performance it is recommended that on a regular basis the unit be
isolated from the power supply and a vacuum cleaner used to
remove dust and fluff from the inlet and outlet grilles.
Regulations require that electrical work be carried out by
authorised persons. For your own safety and that of others, ensure
this is done.
Do NOT allow the supply cord to come into contact with heated
surfaces during operation.
If the supply cord becomes damaged, it must be replaced by a
SKOPE authorised service agent, or similarly qualified person, in
order to avoid a hazard.
3
988E
SKOPE Deluxe Bathroom Fan Heater
Safety Cutout
Your SKOPE 988E Deluxe Bathroom Fan Heater is fitted with an auto-
reset thermal cutout and a fusible link. Either of these devices will
automatically switch off the elements and the motor, should the unit
reach an abnormal temperature. Should this occur:
1.Disconnect heater from power supply
2.Check for blockage of the air inlet and outlet
3.Use a vacuum cleaner to clean if necessary
If the heater still fails to operate, contact your nearest authorised
service agent.
Operation
Air is drawn through the slots in the cover of the heater by a tangential
fan, blown over heating elements, and then blown out through the
bottom louvred grille into the room. The heater is controlled by the pull-
cord switch.
The heat output is regulated by an internal, step-down, thermostat
which will reduce the output from 2200-2400 Watts to 1100-1200
Watts, when a comfortable room temperature is reached. The heat
output is shown by the two neon indicators on the front grille:
One neon glowing: the heater is operating at 1100-1200 Watts
Two neons glowing: the heater is operating at 2200-2400 Watts
Alternatively the heater can be operated via external wall switches,
fitted during installation, which as well as turning the heater on and off
can also override the thermostat, acting as a ‘Boost’ switch.
Care
The heater is best wiped down, from time to time, with a damp cloth. Do
not use any abrasive cleaners.
4988E
SKOPE Deluxe Bathroom Fan Heater
Specifications: model 988E
SKOPE Industries Limited reserve the right to alter specifications without notice.
Contact Addresses
Electrical
Supply: 230-240 Volts a.c. 50 Hz.
Wattage: 2200-2400 Watts, thermostatically reduced to 1100-1200 Watts
Wiring: 600mm flexible cord fitted with 3-pin plug
Ingress Protection Rating: IPX1
Dimensions
Height: 235mm
Width: 460mm
Depth: 112mm
Weight: 4.4 kg
New Zealand
SKOPE INDUSTRIES LIMITED
PO Box 1091, Christchurch
New Zealand
Freephone: 0800 947 5673
Fax: (03) 983 3896
Email: enquiry@skope.co.nz
Website: www.skope.co.nz
Australia
SKOPE AUSTRALIA PTY LTD
A.C.N. 000 384 270
PO Box 7543, Baulkham Hills
NSW 2153, Australia
Freephone: 1800 121 535
Freefax: 1800 121 533
Email: enquiry@skope.com.au
Website: www.skope.com.au