JUNG TKTR24U Operating instructions

Type
Operating instructions
Product Information
DCM Door release relay (flush mounted)
TK TR 24 U
Safety instructions
!
Assembly, installation, and commissioning must only be carried out by a qualified
electrician!
For work on systems with 230 V AC mains current the safety requirements of DIN VDE
0100 must be observed.
When installing DCM BUS systems the general safety rules for telecommunication sys-
tems in accordance with VDE 0800 must be observed:
separate cabling for high and low voltage lines
minimum distance of 10 cm for joint cabling arrangements,
use of separators between high and low voltage lines in joint cable ducts,
use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm² cross section
!
Suitable lightning prediction must ensure that a voltage of 32 V DC will not be
exceeded at the DCM BUS wires a and b.
Application / Brief description
Application
The TK TR 24 U is a door release relay for the opening of a selective door, if multiple
outdoor stations and door releases are integrated in a DCM system. The relay opens
the door, where the door call has been triggered.
also for the activation of additional bell button and bell signal systems
for the evaluation of conrol function of the indoor station
location-independent installation by means of direct bus connection
Brief description
Floating contact for door release 24V/2A DC
Door release time can be programmed
For the installation into flush mounted wall box
2
Trigger the device:
!
You can only program the TK TR 24 U with the TK service device or commissioning
software.
The make contact of the TK TR 24 U can be triggered with different methods:
1) The TK TR 24 U shall assigned to a certain outdoor station as a door release relay.
The TK TR 24 U has to be programmed with the AS-address of these outdoor station.
The device will be triggered with a door release command for the respective outdoor sta-
tion.
2) In an non-programmed condition the TK TR 24 U can be triggered with its serial num-
ber. By means of triggering a door call you can e.g. release an optical door call indication
or an additional door bell. (see page 6)
3) Trigger an optical door call indication or an additional door bell (see page 6) additional
with an internal call or the door bell button: Program the TK TR 24 U with a parallel serial
number additional to step 2) ! (only possible with commissioning software)
4) The TK TR 24 U can be programmed with a control function to trigger the TK TR 24 U
with the function button of the indoor station.
Device overview
BUS connection
terminal
Relay connection
terminal
Jumper
3
Installation
Installation into flush-mounted wall box
Note
!
Outdoor installation:
Ensure, that no water can penetrate into the device !
Wiring example
Connecting diagram 3-wire operation Connecting diagram 2-wire operation
Remove jumper for 3-wire operation!
for 2-wire operation install a
max. of 10 x TKTR24U
External power supply
4
Programming of door release relay
The TK TR 24 U has to be programmed with the TK service device or the commissioning
software.
Switching time settings
You can program the switching time of the TK TR 24 U. The factory setting is 2 seconds.
Trigger external door release
The door release will be triggered via the switching contact of the TK TR 24 U
Selective door release
The door release command of the indoor station always triggers the last calling outdoor
station. Program and lock the outdoor station with a fixed AS-address to ensure a proper
assignment of the TK TR 24 U.
External
p
ower su
p
p
l
y
Floor
bell button
Floor
bell button
5
Wiring diagram: The TK TR 24 U can be supplied via the power supply & control unit
(terminals 19, 20). The door release time will be set in the TK TR 24 U.
At the power supply & control unit you set the time, for how long the supply shall be avail-
able. The time at the power supply & control unit shall be set longer than the release time
at the TK TR 24 U to ensure a sufficient power supply.
Floor
bell button
Floor
bell button
6
Visual door call indication, additional door bell or other additional devices
Install the TK TR 24 U for the switching of various additional devices.
The TK TR 24 U can be triggered by means of door call, internal call or floor bell call.
Visual door call indication: Additional door bell:
Programmieren Sie die Seriennummer des TK TR 24 U auf die Klingeltaste der Außensta-
tion (zusätzlich zu der Sr-Nr der verwendeten Innenstation).
Programmieren Sie die Schaltzeit nach Kundenwunsch.
The triggering of the TK TR 24 U by means of internal call or floor bell button can only be
programmed with the Commissioning Software.
Place the checkmarks as shown in the following figure and type in the serial number of the
indoor station.
external
power supply
7
Technical Data
Supply voltage: +24 V DC ± 8 %
Dimensions: 52 x 52 x 23 mm
Weight 25 g
Admissible ambient temperature: -20 °C ... 50 °C
Input current (2-wire): I(a) = 0.9 mA
Input current (3-wire): I(a) = 0.4 mA
I(P) = 0.5 mA
I(Pmax) = 12 mA
Protection level: IP10
Screw terminals: 0.4 ... 0.8 mm
Recommended wire strip-off: 5 ... 6 mm
Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal provisions.
Please return the unit postage paid to our central service department giving
a brief description of the fault:
ALBRECHT JUNG GMBH & CO. KG
Service-Centre
Kupferstr. 17-19
44532 Lünen
Germany
Service-Line: 0 23 55 . 80 65 51
Fax: 0 23 55 . 80 61 89
Technique (DCM)
Service-Line: 0 23 55 . 80 65 52
Fax: 0 23 55 . 80 62 55
Albrecht Jung GmbH & Co. KG
P.O. Box 1320
58569 Schalksmühle
Germnany
www.gb.jung.de
www.jung-catalogue.com
The
-sign is a free trade sign addressed
exclusively to the authorities and does not include
any warranty of any properties.
Technical subjects to change.
EN_TKTR24U.doc
02/2011
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

JUNG TKTR24U Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI