TCS AMI10300 Product information

Type
Product information

This manual is also suitable for

TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Product information
Series AMI
Front-door stations with display module
AMI10105
AMI10200
AMI10300
AMI10400
Note on the validity of this product information
This product information states specific information on the modules.
It is only valid in combination with the enclosed product information Modules of the series
AMI in front-door stations.
2 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Table of contents
Note on the validity of this product information ................................................................. 1
Table of contents ............................................................................................................... 2
Scope of delivery ............................................................................................................... 3
Module descriptions .......................................................................................................... 4
Loudspeaker module AMI10200 ...................................................................................... 4
Display module LCD graphic AMI1010x ........................................................................... 5
Keypad module AMI10300 Jogwheel AMI10400 ........................................................... 7
Installation .......................................................................................................................... 8
Install the display module into the front panel .................................................................. 8
Remove the display unit from the module plate ............................................................ 8
Install the module plate and display unit in the front panel ........................................... 8
Connect the lines ............................................................................................................... 9
Internal connection of modules within the front-door station ............................................ 9
placement example for keypad module ........................................................................ 9
placement example for jogwheel module ...................................................................... 9
Wiring example............................................................................................................... 10
Connection diagram ....................................................................................................... 10
Commissioning ................................................................................................................ 11
Note on connecting the PS/2 keypad to the display module .......................................... 11
Commissioning of a front-door station with display module ............................................ 11
Configuration ................................................................................................................... 12
Factory settings .............................................................................................................. 12
Configuration options ..................................................................................................... 12
Display module AMI1010x .......................................................................................... 12
Settings ............................................................................................................................. 12
Operation of the front-door station ................................................................................ 13
Calling a resident............................................................................................................ 13
... via selecting the initial letter .................................................................................... 13
... via selection in the resident list ............................................................................... 14
... by entering the flat number ..................................................................................... 15
Voice connection ............................................................................................................ 15
Door release via codelock (only for front-door stations with keypad module) ................. 16
Repair ................................................................................................................................ 17
Display module AMI1010x: Replace the EEPROM storage ........................................... 17
Observe when transfer data from a previous version ..................................................... 17
Accessory ......................................................................................................................... 18
Notes ................................................................................................................................. 19
Service .............................................................................................................................. 20
05/2013 3
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Scope of delivery
Scope of delivery
Delivery item
Module combination LCD display and
loudspeaker module AMI10105-07xx*
keypad module
AMI10300
jogwheel module
AMI10400
display
module
4 x locking nut M4
3 x spacer foil 0.5 mm
allen key 2.5 mm
screwdriver with round
handle
programming manual
Functional group with
display module
AMI1010x
product information
Modules of the series
AMI in front-door sta-
tions
product information
Functional group with
display module
* Display module and loudspeaker module are delivered together as module combination LCD display and
loudspeaker module AMI10105-0757 or AMI10105-0710
!
To set and programme the display modules, you need exclusively a PS/2 keypad
(not enclosed in the delivery, see Accessory, page 18)!
It is not possible to use a PC keypad with USB connection or a USB adapter!
4 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Module descriptions
A front-door station with display module for up to 1000 flats consists of:
a module combination LCD display and loudspeaker module
and keypad or jogwheel module
Loudspeaker module AMI10200
Overview
1 microphone
2 cover PS/2 socket
Loosen the cover with allen
key of 3 mm (not included in
the delivery).
Connect PS/2 keypad.
3 connection cable micropho-
ne
4 connection cable PS/2 key-
pad / jogwheel module
5 connection cable loudspea-
ker
Technical data
housing
aluminium anodised
H x W x D
105 x 105 x 27 mm
weight
235 g
1
2
3
4
5
05/2013 5
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Display module LCD graphic
Overview
1 LC display
2 connection cable
keypad module
3 connection of micro-
phone
4 connection of jogwheel
module or PS/2 keypad
5 EEPROM
6 connection of Service
Device TCSK-01
7 connection of
TCS-BUS
®
, pluggable
screw terminal
8 connection of
loudspeaker
9 matching resistor-
for RS485
10 RS485
11 USB Typ B 1.1 / 2.0
Technical data
display
160 x 160 pixel, white-blue
module plate
glass inserts
housing display unit
aluminium anodised
polycarbonate PC-AR
steel zink-coated
H x W x D
131 x 111 x 45 mm
weight
560 g
acceptable ambient temperature
20 °C to +50 °C
input current standby
max. input current
I(a) = 0.4 mA, I(P) = 140 mA
I(Pmax) = 245 mA
RS485 interface
matching resistor
transmission
120 Ohm (plugged ex works)
half duplex (2-wire connection and 1 x ground with
option for jumper),
recommended baud rate: 9600 baud
can be used with ADx configurator,
use only RS485-PC interface with galvanic isolation!
3-wire technique necessary!
1
2
3
4
5
6
7
11
10
9
8
6 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Short description
Display module for front-door stations in individualised assembly
for up to 1000 flats
LC display, 160 x 160 pixel with white-blue backlight
code lock function (number of codes: 3)
call destination selection via an alphabetically sorted resident list or by entering the tar-
get number (flat number) as quick selection
adjustable (rotation) direction in the name list, name list as of 6 data sets endless
name pre-selection can be realised via the initial letter
start screen can be configured by a qualified electrician
multi-lingual user guidance (can be programmed during the installation: German,
English, French, Danish, Dutch, Turkish, Serbian, Italian, Spanish, Portuguese,
Swedish, Slovak, Slovene, Czeck)
indication of date and time
automatic switch-over between summer and winter time
optionally outdoor temperature indication (temperature sensor FBS2100-0600 not in-
cluded in the delivery, see Accessory, page 18)
import function for old databases of predecessors
acknowledgement tone when pressing the bell button
acknowledgement tone for the start of the voice connection
output of voice messages for user guidance
communication time ex works: 56 seconds / can be adjusted with PS/2 kexpad (not in-
cluded in the delivery, see Accessory, page 18) or ADx configurator (part of the mainte-
nance package FBI1210-0; not included in the delivery, see Accessory, page 18)
S-terminal to trigger door release, light switch, control or door call function (max. length
of the entrance connection line: 2 m)
R-terminal to connect an extended function door release
per resident dataset, 2 serial numbers can be stored
can be adjusted with PS/2 keypad or ADx configurator:
door release time at R-terminal ex works: 3 seconds /
door release in door standby time /
door standby time (to control the short-term memory in indoor stations) ex works: 56
seconds /
voice connection in door standby time /
resident dataset and parameter
!
Attention when using the display module!
The display module is permitted exclusively for safety extra low voltage (SELV) and
protective extra low voltage (PELV).
Avoid direct solar radiation (ambient temperature max. +50 °C)!
Direct solar radiation reduces the durability of the liquid crystals in the display.
05/2013 7
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Keypad module AMI10300 Jogwheel AMI10400
Overview Overview
1 number keys
0 … 9
Call a resident by entering the flat
number.
Enter the number when using the
codelock function.
2 ABC button
Open the residents list sorted by
initial letter. Confirm the selected
letter.
ABC button calls up the help
menu when in start screen.
3 navigation buttons
UP / DOWN
Browse within the resident list or
in the menu.
4 bell button
Call a resident.
5 OK button
Confirm the entry /
the menu request.
6 C button
Code lock function:
Enter the access code
7 jogwheel
Selection help menu /
resident list.
Turn to get into the help menu,
turn further to get to the resident
list.
8 connection cable keypad mod-
ule
9 PS/2 connection (IN) loud-
speaker- / jogwheel module
10 PS/2 connection (MAIN)
display / jogwheel module
Technical data
keypad module
jogwheel module
housing
aluminium anodised
aluminium anodised
H x W x D
105 x 105 x 15 mm
105 x 105 x 52 mm
weight
130 g
265 g
Short description
Keypad or jogwheel module for front-door stations in individualised assembly
keypad with 16 buttons to select the name (call destination) and for using the code lock
function (number of codes: 3)
jogwheel to select the name (call destination)
8
7
4
2
9
10
1
2
3
5
6
4
8 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Installation
Install the display module into the front panel
Remove the display unit from the module plate
Loosen the 4 x panhead screws (1)
with the enclosed allen key 2.5 mm.
Pull off the display unit from the module
plate (2).
Install the module plate and display unit in the front panel
Put the module plate (2) onto the front
panel (3) and fix it with the enclosed 4 x
fastening nuts M4 (4).
Note: The sealing strip (5) which sticks
to the module plate must face upwards!
Put the display unit onto the module
plate
and fix it with the 4 x panhead screws
(1).
Note: The orientation arrow (6)
on the type lable must face upwards!
Dismounting has to be realised in re-
verse order!
6
1
3
2
4
4
2
1
5
05/2013 9
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Connect the lines
Internal connection of modules within the front-door station
After the installation within the front panel, the modules themselves have to be wired.
placement example for keypad module
placement example for jogwheel module
1 connection cable loudspeaker module / microphone
1 connection cable loudspeaker module / microphone
2 connection cable loudspeaker module / loudspeaker
2 connection cable loudspeaker module / loudspeaker
3 connection cable keypad / display module
3 PS/2 connection cable jogwheel / loudspeaker module
4 PS/2 connection cable jogwheel / display module
AMI10200
AMI10200
AMI1010x
AMI10300
3
1
1
2
AMI1010x
AMI10400
1
2
3
4
10 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Wiring example
Connection diagram
Note on the FBS2100:
Optionally available: the temperature sensor to indicate the temperature in the
display (not included in the delivery, see Accessory, page 18).
ISH3030
ISH3030
front-door station
floor push
button
floor push
button
Front-door station
05/2013 11
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Commissioning
Note on connecting the PS/2 keypad to the display module
!
To loosen the cover, use an allen key 3 mm (not enclosed in the delivery).
Commissioning of a front-door station with display module
device start
After switching ON the system
screen appears for 5 seconds.
The resident list appears.
30 s after switching on the device,
the start screen appears.
(ex works with TCS logo)
The device is in standby mode.
Start screen to customer requirements
Another logo or image can be configured as
start screen (see enclosed programming manu-
al Functional groups with display module
AMI1010x). Upload the image with the software
ADx configurator into the memory of the front-
door station with modules.
Examples for the start screen
AMI10100
12 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Configuration
Factory settings
Display module
communication time
56 s
door standby time
56 s
door release time
2 s
call time
4 s
master code
1234
code lock function: code
all 0
Configuration options
Display module
!
The display module is delivered pre-configured ex works with the keypad module
AMI10300 (corresponding to keypad new).
When the jogwheel module AMI10400 was selected, the display module must be
configured anew with the software ADx configurator or PS/2 keypad (see any pro-
gramming manual Functional group with display module AMI1010x.)
Settings
!
For setting and programming the display module you need exclusively a PS/2
keypad (not included in the delivery, see Accessory, page 18)!
Using a PC keypad with USB connection or a USB adapter is not possible!
For settings and programming see enclosed programming manual Functional
groupp with display module AMI1010x.
Can be adjusted resp. programmed with PS2 keypad:
volume and microphone sensitivity
add, change or delete a resident
voice volume
display contrast
enter access codes
05/2013 13
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Operation of the front-door station
Calling a resident
... via selecting the initial letter
display
keypad
module
AMI10300
jogwheel
module
AMI10400
start
select the
initial letter
browse
through the
initial letters
select a name
17:19 15,6°C
Adler-Apotheke
Arnold
Baumgarten, E.
Dombrowski, Alf
Frey
OK Hilfe| Rufen
Press the ABC button
to get to the help menu.
Press the ABC button.
Browse:
Press the UP or DOWN
button until the required
initial letter appears.
Confirm the selected
name with OK button.
Browse:
Press the UP or DOWN
button until the required
name is highlighted.
Turn the jogwheel care-
fully to get to the help
menu or
press the ABC button.
A list with the first initials
of the resident names is
displayed.
Browse:
Turn the jogwheel until
the required initial letter
appears.*
Confirm the selection
with the ABC button.
The first resident with the
selected initial letter is
displayed.**
Browse:
Turn the jogwheel until
the required name with
this initial letter is high-
lighted.
Browse through the
resident list:
clockwise upwards
counterclockwiese:
downwards
* The list of initial letters
contains only the initial
letters of names which
are stored in the data-
base.
** Automatic switch-over to
the resident list after 15
seconds.
A B
C
A B
C
14 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
display
keypad
module
AMI10300
jogwheel
module
AMI10400
Call a resident
Press the bell button.
The entered number is confirmed by an acknowledge-
ment tone (or voice output) and the display:
If the telephone does not respond resp. the front-door
station receives no acknowledgement, the following note
appears:
... via selection in the resident list
start,
select a name
browse in the
resident list
17:19 15,6°C
Adler-Apotheke
Arnold
Baumgarten, E.
Dombrowski, Alf
Frey
Rufen
Press the UP or DOWN
button two times.
The resident list is dis-
played.
Browse:
Press the UP or DOWN
button until the required
name is highlighted.
Turn the jogwheel care-
fully to get to the help
menu or
Browse:
Turn the jogwheel until
the required name is
highlighted.
Call a resident
Press the bell button.
The entered number is confirmed by an acknowledge-
ment tone (or voice output) and the display:
If the telephone does not respond resp. the front-door
station receives no acknoledgement, the following note
appears:
05/2013 15
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
... by entering the flat number
Display
keypad module AMI10300
Enter the flat
number
If the flat number of the resident is known, it can be en-
tered directly.
Enter the flat number (digits 0 till 9).
Confirm the entry with the OK button.
Call a resident
Press the bell button.
Confirming of the entered number by the display:
A door call sounds at the front-door station.
If the telephone does not respond resp. the front-door
station receives no acknowledgement, the following note
appears:
Voice connection
Establish the
voice connec-
tion
After accepting the door call at the called indoor station, a
voice connection is established.
It is displayed:
End the voice
connection
17:19 15,6°C
Adler-Apotheke
Arnold
Baumgarten, E.
Dombrowski, Alf
Frey
Rufen
By putting down the handset at the indoor station or after
the adjusted period of communication time is over, the
voice connection is terminated.
The resident list is displayed again.
16 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Door release via codelock (only for front-door stations with keypad module)
For display front-door stations with keypad module, three access codes can be set. These
can be used for the door release by all authorised persons.
The enter menu can only be called up from the start screen.
display
keypad module AMI10300
Enter the ac-
cess code
Entry correct
Unknown
access code
Press the C button.
The following is displayed:
Enter the code with 1 to 4 digits.
Confirm the entry with the OK button.
A positive acknowledgement tone (beep or voice out-
put) sounds.
The door opener is triggered.
A negative acknowledgement tone (3 times beep or
voice output) sounds when pressing the OK button.
The resident list is displayed.
If the code is entered incorrectly 3 times, the code input
is blocked for 180 sec.
05/2013 17
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Repair
Display module AMI1010x: Replace the EEPROM storage
!
Modifications of dataset and parameter are not stored automatically.
After all modifications, carry out the following steps Various > save storage, to trans-
fer the modifications on the EEPROM (see enclosed programming manual Func-
tional group with display module AMI1010x).
All programmed data such as serial numbers and parameter are stored in the EEPROM. If
the front-door station needs to be replaced, the EEPROM storage can be removed from
the programmed front-door station and installed into the new, comparable front-door sta-
tion.
1. Eventually save the data of the display (Various > Save storage).
2. Open the housing.
3. Disconnect the display from the power supply: pull off the connection socket.
4. The EEPROM storage is located in the elctronic part (corresponding to the display
module). Pull off the EEPROM storage.
5. Plug the EEPROM storage into the new, unprogrammed display module on the pins.
!
Observe the orientation of the EEPROM storage: the component site must be facing
you.
6. Connect the front-door station to mains voltage again.
7. Conduct Load storage. Observe the software version (Various > Load storage, page 20)
to transfer the data into the electronic module.
Observe when transfer data from a previous version
After the upload process is finished (step 7), remove the EEPROM storage of the dis-
play front-door station DIT (software version 2.7.x / 3.x.x) out of the display module
again. Otherwise the real time clock doesn’t work any longer.
18 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Accessory, spare parts
Short text
Article number
Temperature sensor flush-mount, single
FBS2100-0600
PS/2 keypad, German (for display module AMI1010x)
0008737
Maintenance package
FBI1210-0
Display module LCD graphic, 1000 flats, anodised black
AMI10105-0000
Loudspeaker module, anodised black
AMI10200-0057
Display module LCD graphic, 1000 flats, anodised silver
AMI10105-0010
Loudspeaker module, anodised silver
AMI10200-0010
05/2013 19
TCS TürControlSysteme AG, TCS Hotline Germany: hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Notes
20 05/2013
TCS TürControlSysteme AG, TCS Hotline Germany : hotline@tcsag.de Subject to technical changes.
Fax: +49 (0) 41 94 / 9 88 129 PI_AMI_FG-DISPLAY-uk 2A
Service
Please send your questions and inquiries to
Headquarters
TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin
Phone:+49 (0) 39 33 / 87 99 10, Fax +49 (0) 39 33 / 87 99 11, E-Mail: info@tcsag.de, www.tcsag.de
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

TCS AMI10300 Product information

Type
Product information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI