XCELERATE SERVICE INSTRUCTIONS • XLSERVICE • 18
www.alto-shaam.com
|
800-558-8744
|
262-251-3800
STEP 6
Power the oven back on, place a cup of water inside the
oven, then start the microwave. Normally there should
be 6 to 8 Amps going through S32, and all microwave
components are working properly. If the water still does
not heat check if the antenna in the top of the baking
chamber is installed properly.
If you measure a current higher closer to 12A the
magnetron is likely faulty or broken. Alternatively,
the transformer could also be damaged. Change the
magnetron first then the transformer since the magnetron
is most likely to fail.
If the measure is a lower current closer to 3A, it is likely
the diode is damaged or broken.
If the measure is 4 – 5A, it is likely the capacitor is
damaged or broken.
Finally if there is no current at all, please check for lose
cable connection or that all door switches are properly
closed.
These are the components most likely to be affected
but are by no means the only components that may be
affected.
STEP 7: CHECKING THE CONTROL CIRCUIT
Disconnect the oven from the main power. Remove the
cables T2L and T2N from the transformer and connect
your volt meter.
STEP 8
Power the oven back on, close the door and start
microwave operation. When you start you should measure
line voltage at the cables T2L and T2N. Then the
microwave circuit is supplied with power correctly and
proceed with STEP 9.
If there is no voltage when the microwave function is
started, check if the microwave output of the control PCB
is active. If not, the door switch input of the PCB may
not be active. Check K2 and S1, which produce the input
signal. It is very unlikely the PCB itself has a problem,
andthereusuallyisnoneedtochangethePCB!
Check if Relays/Contactor K1 is working.
Check the function and adjustment of the door switch
assembly.
Xcelerate™ Hi-Speed Oven
CHECK MICROWAVE