Unical OSA S, Ufly BOX User manual

  • Hello! I am an AI chatbot trained to assist you with the Unical OSA S User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
ENGLISH
TOUCH CONTROL
INSTALLATION AND SERVICING MANUAL
Uy BOX
3
1
Description
KEY
1 RJ cable for wiring to BMM boiler.
2 Display Touch
3 Led di stato
green
In operation OK (xed light)
red
Failure deyected (ashing light)
4 Magnets for xing
5 RJ plug
1.2 - Part description
1.1 - Reading Icons
Buttons and symbol (outline + lled color area)
This service is in operation at that time
Buttons and symbol (outline in dark grey no lled
area)
Disabled or switched off service but present or
installed
Buttons and symbol (outline + empty color area)
Present and active service but not in operation at
that time
Buttons and symbol (outline in ligh grey no lled
area)
No service or not installed
4
2
Display and functions description
6 Display mode
Disbled
7 Display mode
Home page
8 Display mode
Menù page
2.1 - Display mode
2.2 - Button One page back and Button Home
2.3 - Display in Home page
9
One page back
10
Return always to Home page
11
INFO: see at page 26
5
2.4 - Menù Set up
6
Menù Set up
7
Set parameters
Save changes
Menù Set up
If change language, it is necessary to remove and insert RJ plug, to store
changes.
8
1 Connecting to the net (select Icon Net)
2 Wait and select the dened Net
3
Wait for connection to dened Net, access to
WI-FI Password and digit.
Wait for WiFi - Web
The serial number (GP) is already set at the
bench testing boiler
link Uybox to smartphones
(Wi device)
4
Once installed and start Uy APP (*) from WiFi
device,
5
Link Serial Number of the boiler indicated in
Uy BOX on WiFi device.
6
Wait few seconds, on the display of Uy BOX
will show a random code xxxxxx (**)
in the box Pairing.
7
This code must be reported on the WiFi device.
At this point my WiFi device is correctly linked
to the boiler
(*)
Uy APP at the moment is in testing phase,
It is released on demand from post-sales ofce.
Soon it will be available on the Store and Unical
site.
2
1
5
6
Uy APP (*)
Menù Set up
9
At every boiler lighting, UFLY BOX scans devices, if
new devices are recognized, such as:
hcm /
bcm
Heating / Burner Control Manager
System manager / Cascade
shc
Slave Heating Controller
Multifunction module
bmm
Burner Modul Manager
They are displayed on the next screen, and is
prompted to save the new conguration.
Icon scanning devices
Icon save new conguration
Detected Device
Not installed device
Device previously detected, but not detected
at the moment .
2.5 - Menù Device
10
BMM / HCM Parameter
List of parameter in par. 4.2 instruction manual of the
boiler
To change the parameters is required password.
Hystorical Error
Clean display with Button Clear.
Menù Device
11
Set Day Type
Eventually rename Day 1 Day 5 .....
example: Working day, Weekday, Festive.
Selection circuit CH
Change name to circuit and Save.
2.6 - Menù Heating
12
Set Week Type (1)
Eventually rename Week 1.....Week 3
example: Autumn, Winter, Jolly.
Insert day of the week separately
(mon-tue-wed.-thu.-fri.-sat-sun) the day type
Day1....Day5.
Set Week Type (2)
Insert day of the week join the day
(mon-fri-sat-sun) the day type Day1....Day5
Set periods
3 Time slots.
13
Select circuit to show set program
Standby
Comfort
Eco
Week1
Week2
Week3
14
Touching the icon
It shows only the details of the program in the
1-2-3 ... period.
Menù Heating
15
The parameters displayed are relative to the hea-
ting program.
Note:
- To change the heating parameters is not neces-
sary to go in the DEVICES menu.
- The psw remains active until you return to the
MENU’.
Edit Parameters Heating circuit.
Touching Settings icon you can change the hi-
ghlighted parameter. It is required password.
For other parameters you need not password.
Menù Heating
16
Working Manual set the parameter
Is it possible View and Modify program and HEATING
parameters
Example Boiler in Error (Block):
Reset the boiler with R button
From Home Page
Activation in Working Manual
Return to operation with the set program (automatic).
Menù Heating
17
Set Day Type
Eventually rename Day 1.....Day5
example: Working time, Weekday, Festive.
2.7 - Menù DHW
Set periods
3 Time slots.
18
Menù DHW
Set Week Type (1)
Eventually rename Week 1.....Week 3
example: Autumn, Winter, Jolly.
Insert day of the week separately
(mon-tue-wed.-thu.-fri.-sat-sun) the day type
Day1....Day5.
Set Week Type (2)
Insert day of the week join the day
(mon-fri-sat-sun) the day type Day1....Day5
19
Menù DHW
Select circuit to show set program
Standby
Comfort
Eco
Week1
Week2
Week3
20
Legionella protection activation
The parameters displayed are relative to the heating
program.
Note:
- To change the heating parameters is not ne-
cessary to go in the DEVICES menu.
- The psw remains active until you return to the
MENU’.
Edit Parameters DHW
Touching Settings icon you can change the highli-
ghted parameter. It is required password.
For other parameters you need not password.
Menù DHW
Touching the icon
It shows only the details of the program in the
1-2-3 ... period.
/