7.8
Custom Hood Liners
IHL
IHL SERIES HOOD LINER DIMENSIONS
VENTILATION SYSTEM COMPATIBILITY
Custom hood
Dacor IVS series integrated
ventilation system
Hood liner mounting screw,
number required varies with
model, see table
Cap nuts/lock washers for mounting IVS
(provided with IHL kit)
21"
(53.3 cm)
13 7/16"
(34.1 cm)
4" (10.2 cm)
A
Mounting hole
for IVS
IHL mounting hole,
number and locations
vary with model
C
L
All tolerances: ±1/16” (±1.6 mm) unless otherwise stated.
Document # PG07-005
Revised 09/29/10 Page 1/1
WARNING
• Observe all governing codes and ordinances during planning
and installation. Contact your local building department for
further information.
• This appliance must be installed in accordance with the
accompanying installation instructions.
IHL Model
(A) Width
Dimension
Number Mounting
Holes/Mounting
Screws Required*
IHL30 27” (68.6 cm) 4
IHL36 33” (83.8 cm) 4
IHL42 39” (99.1 cm) 6
IHL48 45” (114.3 cm) 6
IHL54 51” (129.5 cm) 6
IHL Model IVS Model
IHL30 IVS1
IHL36 IVS1
IHL42 IVS2
IHL48 IVS2
IHL54 IVS2
The Dacor IHL series integrated hood liner is used to line the inside of
custom built range hoods. It is constructed with non-combustible stainless
steel and is designed for use with Dacor IVS series integrated ventilation
systems. Together the IVS and IHL series products can be built into a
custom hood structure to provide the required ventilation and heat resistant,
easy to clean surfaces.
Dacor IHL series
hood liner
* #8 screws required, length and type must be determined
according to application (mounting material).
  • Page 1 1