  • Hello! I am an AI chatbot trained to assist you with the Dacor IHL48 Installation Instructions PDF [0.75 MB]. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Installation Instructions
Integrated Hood Liner
Covers models IHL30, IHL36, IHL42, IHL48 and IHL48
Part No. 65268 Rev. D
© 2007 Dacor
®
, all rights reserved.
1
Installation Instructions ................................................. 3-4
Installation Planning ......................................................... 3
Electrical Connection ....................................................... 4
Installing the IVS .............................................................. 4
Verifying Proper Operation ............................................... 4
Table of Contents
Important Information About
Safety Instructions
The • Important Safety Instructions and warnings in
these instructions are not meant to cover all possible
problems and conditions that can occur. Use common
sense and caution when installing, maintaining or
operating this or any other appliance.
Always contact the Dacor Customer Service Team •
about problems and conditions that you do not
understand.
Safety Symbols and Labels
DANGER
Immediate hazards that WILL result in severe personal
injury or death.
WARNING
Hazards or unsafe practices that COULD result in severe
personal injury or death.
CAUTION
Hazards or unsafe practices that COULD result in minor
personal injury or property damage.
Before You Begin...
Before You Begin... ........................................................... 1
Important Safety Instructions ....................................... 1-2
Important Information About Safety Instructions .............. 1
General Safety Precautions ............................................. 2
All specifications are subject to change without notice. Dacor
assumes no liability for changes to specifications.
Important Safety Instructions
Important:
Installer:• In the interest of safety and to minimize
problems, read these installation instructions
completely and carefully before you begin the
installation process. Leave these installation
instructions with the customer.
Customer:• Keep these installation instructions for
future reference and the local electrical inspector’s use.
If you have questions or problems with installation, contact
your Dacor
dealer or the Dacor Customer Service Team.
For repairs to Dacor products under warranty, call the
Dacor Distinctive Service line. Whenever you call, have the
model and serial number of the product ready.
Dacor Customer Service
Phone: (800) 793-0093 (U.S.A. and Canada)
Monday — Friday 6:00
a.m. to 5:00 p.m. Pacific Time
Web site: www.Dacor.com
Dacor Distinctive Service (repairs under warranty only)
Phone: (877) 337-3226 (U.S.A. and Canada)
Monday — Friday 6:00
a.m. to 4:00 p.m. Pacific Time
2
Important Safety Instructions
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
Use this unit only in the manner intended by the 1.
manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning unit, switch power off 2.
at service panel and lock the service disconnecting
means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the
service panel. Exception: The additional safety
instructions do not apply to a ceiling-suspended
fan.
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE:
Never leave surface units unattended at high 1.
settings. Boil overs cause smoking and greasy
spillovers that may ignite. Heat oils slowly on low or
medium settings.
Always turn hood ON when cooking at high heat or 2.
when cooking flaming foods.
Clean ventilating fans frequently. Grease should not 3.
be allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware 4.
appropriate for the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS
IN THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING*:
SMOTHER FLAMES with a close-fitting lid, cookie 1.
sheet, or metal tray, then turn off the burner. BE
CAREFUL TO PREVENT BURNS. If the flames
do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - You may be 2.
burned.
DO NOT USE WATER, including wet dishcloths or 3.
towels - a violent steam explosion will result.
Use an extinguisher ONLY if:4.
a) You know you have a Class ABC extinguisher,
and you already know how to operate it.
b) The fire is small and contained in the area where
it started.
c) The fire department is being called.
d) You can fight the fire with your back to an exit.
*Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
General Safety Precautions
To reduce risk of fire, electric shock, serious injury or death when using your appliance, follow basic precautions, including
the following:
WARNING
CAUTION
For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3
Installation Instructions
The Dacor integrated hood liner (IHL) is constructed
with non-combustible stainless steel material. The IHL
dimensions and design make it an excellent component
for any custom hood structure. Dacor offers two integrated
ventilation system products (IVS1 and IVS2) which
conveniently install on the pre-mounted installation lugs
around the opening at the top of the hood liner.
Plan the installation so that all minimum clearances are
met or exceeded. Dimensions shown provide minimum
clearances, unless otherwise noted.
Installation Planning
NOTES:
Dacor IHLs have no electrical parts.•
#8 mounting screws (not provided) are required to •
install the IHL. The length and type must be determined
according to the application (mounting material). See
the diagrams below to determine the quantity required
for the model being installed.
For proper installation of the complete IHL/IVS custom •
hood ventilation system, the installer must follow
the installation information in the IVS Installation
Instructions. Follow all electrical requirements specified
in the IVS Installation Instructions.
The IVS is attached to the IHL using the 8-32 cap nuts •
and lock washers provided with the IHL kit. Quantity
varies according to kit.
The IHL is designed for vertical on center ducting •
applications only.
The IHL30 and IHL36 liners are designed for installation
with the 600CFM IVS1 integrated ventilation system.
For additional specifications refer to the IVS Installation
Instructions.
21"
(53.3 cm)
4" (10.2 cm)
B
Model
IHL42
IHL48
IHL54
(B)
39" (99.1 cm)
45" (114.3 cm)
51" (129.5 cm)
IVS2 mounting
studs (12 places)
IVS2 integrated
ventilation system
IHL mounting hole
(6 places)
13 7/16"
(34.1 cm)
C
L
Figure 2: IHL42/48/54 Overall Dimensions
Top View
13 7/16"
(34.1 cm)
21"
(53.3 cm)
4" (10.2 cm)
A
Model
IHL30
IHL36
(A)
27" (68.6 cm)
33" (83.8 cm)
IVS1 mounting
studs (6 places)
IVS1 integrated
ventilation system
IHL mounting hole
(4 places)
C
L
Figure 1: IHL30/36 Overall Dimensions
Top View
The IHL42, IHL48 and IHL54 liners are designed for
installation with the 1200CFM IVS2 integrated ventilation
system. For additional specifications refer to the IVS
Installation Instructions.
4
Installation Instructions
Electrical Connection
Refer to the IVS Installation Instructions.
Installing the IVS
Mount the IHL using #8 mounting screws (not 1.
provided). See the diagrams on page 3 to determine
the required quantity and type. Install them through the
top of the liner.
Attach the IVS to the IHL mounting studs using the cap 2.
nuts and lock washers included with the IHL kit.
Verifying Proper Operation
Refer to the IVS Installation Instructions.
NOTE: If the blower does not operate properly, follow these
troubleshooting steps:
Verify that power is being supplied to the integrated 1.
ventilation system.
Check the electrical connections to ensure that the 2.
installation has been completed correctly.
If the appliance still does not work, contact Dacor 3.
Distinctive Service at (877) 337-3226. Do not attempt
to repair the appliance yourself. Have the model and
serial numbers available when you call.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
IHL
IVS
Custom hood
IHL mounting
screw, number
required varies
with model,
see page 3
Cap nuts/lock washers for
mounting IVS (provided with
IHL kit, quantity varies)
Dacor●600AntonBlvd.Suite1000CostaMesa,CA92626●Phone:(800)793-0093●Fax:(626)403-3130●www.Dacor.com
/