Fig. 2
7. View the LED displays on the front of the oven.
• The oven briefly flashes the in-application
program version IAP 6.21 on the timer
display.
8. "Usb Flsh n_y” appears on the display.
• If something other than "Usb Flsh n_y" is
displayed, then refer to USB ERROR
MESSAGES.
• If "n" is selected with the humidity knob
(turned to the left, ccw), the oven will return
to Idle mode. Firmware not updated.
• If "y" is selected (turned to the right, cw), the
humidity display briefly changes to show
"yes", then "del" as the necessary flash is
deleted, then begins showing a percentage
complete from 0-100 as the software image
is flashed. When flashing is complete
(usually after a few seconds), the humidity
display briefly shows "don", which indicates
the software flashed correctly. Oven returns
to the Idle Mode (Temperature display - - -).
Firmware is updated.
9. Enter Configuration Mode (1972),
• Verify that parameter P0 now shows
4-24-17 as the firmware revision code.
• Enter oven hour count, found in parameter
P18 on the service ticket.
10. Update the In-Application Program (IAP).
NOTE: Updating the IAP is highly recommended
when updating firmware from 8-11-14 to 4-24-17 or
later versions. Required for proper operation of the
E14 error and “USB HOST COnn” fix.
NOTE: When updating firmware from 4-24-17 to later
versions skip to step 11.
A. Continue in configuration mode (1972), with
the USB flash drive remaining inserted.
B. Turn temperature knob clockwise to P72.
“2000” shows on timer display.
C. Turn timer knob counterclockwise to enter
password “1972” allowing access. "Eng"
shows on timer display.
D. Turn temperature knob counterclockwise to
P65. Display will show “FIAP no”.
E. Turn humidity knob clockwise to select “yes”
to request IAP firmware update. Display will
show “IAP FLSH n_y”.
NOTE: If oven does not respond, select “yes” again.
F. Turn humidity knob counterclockwise to
select “y” and initiate IAP download.
Selecting "n" will cancel back to P65.
• Display will show “USb flsh don”.
• Display will briefly show “IAP 6.21”
(watch for this to verify the IAP updated
correctly).
• Display will show “IAP FLSH n_y”,
asking to re-flash the oven firmware
(not IAP firmware) again. Select "n",
but you can select either “y” or “n”
without issue.
• Oven exits configuration mode, and
returns to Idle Mode (Temperature
display - - - ).
11. Remove USB flash drive.
Updating the Oxygen Sensor Board Firmware
Oxygen sensor board firmware cannot be
updated remotely and must be replaced to get
the current revision. Contact your local Hobart
Service office for the latest replacement part.
USB ERROR MESSAGES
ABC Combi Electric Oven - UPGRADE ABC COMBI FIRMWARE
Page 11 of 110 F45495 Rev. C (0618)