www.esabna.com
DATE: April 21, 2004 BULLETIN NO: M_04_007
TITLE/ PRODUCT NAME: MultiPower 460 Connector Corrosion
RATING:
_
_ DIRECTIVE _X_ ALERT
(Action is Required) (Potential Problem)
_
X_ INFORMATION _ _ PRODUCT IMPROVEMENT
(Action is Optional) (Enhanced Product)
_
X_ General Distribution _ _ Business Confidential
(Unrestricted) (Restricted Distribution)
PRODUCT SERIES/ MODEL:
All Models
SERIAL NO:
All
SUMMARY:
Environmental corrosion problems on equipment sold to costal and off shore facilities have
been a concern for many years. Special equipment designs and manufacturing procedures
have been used to minimize the corrosion problem but complete elimination of corrosion is
difficult to attain.
A recent corrosion event occurred on the Gulf Coast causing a MultiPower 460 to lose voltage
control. Field troubleshooting could not easily identify the problem requiring the unit to be
returned to Florence for evaluation. Further investigation showed that a connector pin on the
current sensing transducer had corroded completely away. This was not obvious during
troubleshooting because the missing pin on the transducer was easily overlooked upon visual
inspection. See photos.
OPERATIONAL IMPACT:
None