Gecko in.k600 si Quick Start Card

Type
Quick Start Card
Programming Steps
Programming the
filter/ purge cycles
Depending on system
configuration your spa will
perform either a filter or a
purge cycle. The filter cycle
menu consists of the following
parameters: the start time
(FS), the duration (Fd) and the
frequency (FF). The purge cycle
menu consists of the following
parameters: the start time (PS)
and the frequency (PF).
A filter cycle consists of starting
all the pumps and blower in
high speed for
1 minute (purge step) then, the
pump associated with the filter
will run in low speed for the
remaining duration of the filter
cycle (clean step).
A purge cycle is used when the
spa is equipped with a 24 hour
circulation pump which pro-
vides a continuous clean step.
It consists of starting all the
pumps and blower in high
speed for 1 minute.
On/Off key
Depending on the spa
manufacturer, this key may
have one of the two following
functions: On/Off or Standby
mode and/or Economy mode.
On/Off mode: This mode
allows you to stop all outputs
including all automatic functions
such as filter cycle, heat request
and smart winter mode purge
for 30 minutes to perform quick
spa maintenance. To enter the
On/Off mode, just press and
release the On/Off key. The
display will togglebetween the
Stbymessage and the water
temperature. Press the On/Off
key again to restart the system
before the expiration of the 30
minutes delay. The spa light will
flash a few seconds before the
end of the 30 minutes to warn
you the system is about to resu-
me its normal operation.
Standby Mode: This mode
allows you to stop all outputs
and automatic functions with
the exception of the heat
request for 30 minutes. To enter
the standby mode, just press
and release the On/Off key.
The display will toggle between
the “Stbymessage and the
water temperature. Press the
On/Off key again to restart the
system before the expiration of
the 30 minutes delay. The spa
light will flash a few seconds
before the end of the 30 minu-
tes to warn you the system is
about to resume its normal
operation.
Manual Economy Mode*:
This mode allows you to save
some energy by regulating the
water temperature 20°F (11°C)
below the actual set point. To
enter the manual economy
mode, make a long press of
5 seconds on the On/Off key.
The display will toggle between
the “Econmessage and the
water temperature. Make a
5 seconds long press again
on the On/Off key to exit the
manual economy mode.
*Available on certain models only.
Pumps 1 to 5
Press on a Pump button to start
the associated pump at low
speed. Press a second time to
move to high speed (for dual
speed pumps*). Press a third
time to shut off the pump. If the
pump is not shut off manually,
a timer will automatically shut
if off after the predetermined
time.
The pump icon will be
animated when the pump is
on. For dual speed pumps, the
animation will be slower at low
speed, faster at high speed.
*Single speed pumps will shut off
with the second press.
Spa Functions
Heating icon Smart winter mode iconProgram icon
Service icon
Filtering icon
Pump iconsLight icon
AM/PM (˚F/ ˚C)
Set point icon
Time, temperature
& message digits
Progress bar icon
Function Description
Blower icon
"Plus" Key
"Program" Key"Ok" Key"Light" Key
"Minus" Key "On/Off" Key"Pump" Keys
"Pump / Left" Key
"Pump / Right" Key
in.k600™ with in.xm™
Compact full-function keypads for
in.xm™ spa systems
Aeware's® advanced in.k600™ keypad features a low profile
with a large LCD display, streamlined interface and raised keys
that let users easily control all in.xm™ functions and program-
ming directly from spa side, creating a true and unique user
experience.
Quick Reference Card
Please consult your spa user manual for complete info on the features of your spa system.
/- keys
Use Up or Down key to set
desired water temperature.
The temperature setting will
be displayed for 5 seconds to
confirm your new selection.
The "Set Point" icon indicates
that the display shows the
desired temperature, NOT the
current water temperature!
Light key
Press Light key to turn light on.
A second press turns light off.
A built-in timer automatically
turns light off after 2 hours,
unless it has been manually
deactivated first.
The “Light” indicator lights up
when light is on.
Blower
Depending on the
configuration os the spa and/
or keypad, the blower will be
activated by either the Pump 3
button or Pump 5 button. The
button will control either the
blower by itself, or the pump
and blower.
Blower only: Press the
associated Pump button to start
the blower. Press the button a
second time to turn it off.
Pump and blower: Successive
presses on the associated
button will have the following
actions (in order): Pump only
Pump and blower – Blower
If the blower is not shut
off manually, a timer will
automatically shut if off after
the predetermined time.only
– Turn off.
9919-100801-C
Rev. 11-2012
Water temperature
regulation
In a regulation cycle, the sys-
tem first generates water flow
through the heater housing
and the plumbing, in order to
ensure accurate water tempe-
rature readings as well as avoi-
ding heater activation in dry
conditions. After verifying
pump activation and taking a
water temperature reading if
required, the system automa-
tically turns the heater on to
reach and maintain water
temperature at Set Point.
The “heater” indicator lights
up when the heater is on.
Indicator flashes when taking
water temperature reading.
Setting temperature unit
Water temperature can be dis-
played in either Fahrenheit
(°F) or Celsius (°C). The display
will show tu x, “x” representing
the temperature unit F or C.
Use the Up or Down key to
change the setting. Use the
Program or OK key to save all
the parameters.
Program/Filter
menu
A quick press of the Prog key will
allow you to display the clock.
A long press of 5 seconds will
allow you to enter the program
menu. In the program menu,
the following parameters can be
set: the clock, the filter cycles or
the purge cycles, the economy
mode and the temperature units.
While you are in the program
menu, use the up or down keys
to adjust the parameters and use
the Prog key jump to the next
parameter. The changes will be
saved after the confirmation of
the last parameter only. If there
is no key press for 10 seconds,
the system will exit the program
menu without saving the
changes.
Filter cycle frequency
The display will show FFxx, “xx”
representing the number of
filter cycles per day. Use the
Up or Down key to adjust the
frequency. Use the Program or
OK key to jump to the next pa-
rameter, economy mode (EP).
The “Filter cycle” indicator
lights up when filter is on.
Flash when suspended.
Setting filter cycle
start time
The display will show FSxx, “xx”
representing the starting hour
of the filter.
Use the Up or Down key
to adjust the hours. Use the
Program or Ok key to jump
to the next parameter, filter
duration (Fd).
Programming steps
Setting filter cycle
duration
The display will show Fdxx,
“xx” representing the duration
in hour of the filter cycle. Use
the Up or Down key to adjust
the duration. Use the Program
or OK key to jump to the next
parameter, filter frequency (FF).
0 = no filtration
24 = continuous filtration
It's not recommended to set
this to "0".
Setting Economy mode
This mode allows you to lower
the temperature set point of
the spa by 20 °F (11 °C) during a
certain period of the day.
The display will show EPx, “x”
representing the state of the
programmed economy
(0 = disable, 1 = enable). Use
the Up or Down key to set the
program economy to enable
or disable. Use the Program
or OK key to jump to the next
parameter, economy start (ES).
Setting the purge cycle
start time
The display will show PSxx, “xx”
representing the starting hour of
the purge cycle. Use the Up or
Down key to adjust the hours.
Use the Program or OK key
jump to the next parameter,
purge frequency (PF).
Setting purge cycle
frequency
The display will show PFxx, “xx”
representing the number of
purge cycles per day. Use the
Up or Down key to adjust the
frequency. Use the Program
or OK key to jump to the next
parameter, economy mode (EP).
The “Purge cycle” indicator
lights up when purge is on.
Flash when suspended.
Setting Economy start
time
The display will show ESxx,
“xx” representing the hour at
which the economy mode
will become active. Use the
Up or Down key to adjust
the hour. Use the Program or
OK key to jump to the next
parameter, economy end
time (EE).
When the Economy mode
is ON, the display will toggle
between the “Econ” message
and the water temperature.
Setting Economy
end time
The display will show EExx,
“xx” representing the hour at
which the system will resume
its normal operation. Use the
Up or Down key to adjust
the hour.
Use the Program or OK key to
jump to the next parameter,
temperature unit (tu).
Smart Winter Mode
Our Smart Winter Mode
protects your system from
the cold by turning pumps on
several times a day to prevent
water from freezing in pipes.
The “SWM” indicator lights
up when a freeze condition is
detected and flashes when the
purge is active.
www.geckoalliance.com
Cooldown
After heating the spa water to
the desired Set Point, the hea-
ter is turned off, but its associ-
ated pump (Pump 1 Low-speed
or CP) remains on for a prede-
termined period of time to
ensure adequate cooling of the
heating element, this prolongs
its useful life. The heater icon
flashes during this time.
Setting the clock
Enter the program menu by
holding down the Program key
for 5 seconds. The display will
show the current clock setting,
the minutes will be on solid and
the hours will flash.
Depending on factory settings
your system may be set to a
24-hour military notation or a
regular 12-hour notation.
Setting the hour: Use the Up or
Down keys to adjust the hours
(AM/PM). Press the Program
or OK key to jump to the next
parameter, the minutes.
Setting the minutes: Use the
Up or Down keys to adjust the
minutes. Press the Program
or OK key to jump to the next
parameter, the filter start time
(FS) or the purge start time (PS).
Program icon: The "Program" icon lights up when Programming.
Progress bar: A visual indication of the time remaining before an
equipment is turned off or before the end of the standby mode.
Set Point icon: The "Set Point" icon automatically turns on when
set point setting menu is activated. (SP message on display).
It flashes when:
1- there is a call for heat and heater has not started yet,
2- heater has just turned off and element is cooling down or
3- if system is performing a check flow.
Service icon: A problem has been detected.
Do not enter the water! Spa service is required.
Light icon: The "Light" icon lights up when the light is on.
Pumps icons: The "Pump" indicator numbers light up and their
icons become animated when pumps are on.
Smart winter mode icon: The "SWM" icon automatically turns
on when freeze protection is active. It flashes while system
purges the spa plumbing.
Filter Cycle icon: The "Filter Cycle" icon lights up when filter cycle
is on. It flashes when filtering is suspended.
Heater icon: The "Heater" icon lights up when the heater is on.
Blower icon: The “Blower” icon lights up when blower is on.
Icon Description
  • Page 1 1
  • Page 2 2

Gecko in.k600 si Quick Start Card

Type
Quick Start Card

Ask a question and I''ll find the answer in the document