Midmark Synthesis® Cabinetry Installation guide

Type
Installation guide

This manual is also suitable for

1
TP200 Rev. A
003-2862-00 Rev. AA1 (1/16/20)
Contents:
Installation ...........1-3
Exploded View ........ 4
Special Tools:
none
Language of origin: English
Tall Cabinet Drawer Single Keyless
Lock Installation [002-1973-xx]
Step 1:
Remove drawers and slides as needed from cabinet.
Remove screws (3) from Mullion inside the cabinet to release.
Mullion
Screw
Screw
Slides
Note
This install can be used for any Tall Cabinet Single Drawer Keyless Lock installation. The assembly
process will be the same. The Lock Bar will be a different size depending on the number of drawers.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | www.midmark.com
Style A
2
TP200 Rev. A
003-2862-00
Step 7:
Install cam lock inside cabinet with lock bar spring
attached.
Step 5:
Install mullion onto cabinet with screws(3).
Step 6:
Assemble lock bar spring onto cam lock.
Step 4:
Measure 1/4” from 3/4” hole and mark as shown. Use hole
punch and hammer to start mounting holes. Note: Make
sure mounting mark is parallel with mullion.
Step 3:
Measure 2-25/32” from 3/4” hole and mark hole as shown.
Drill 5/32” hole in mullion. Insert Thread Insert groove first
into mullion. Note: Keep insert flush with mullion face.
Step 2:
Measure from edge of mullion mark and drill 3/4” hole
through mullion.
Mullion
Lock Bar
Spring
Lock Bar
Spring
Mullion
CAB WIDTH
Lock Position
12” 4 - 25/32”
15”, 18”, 21” & 24” 4 - 7/8”
30” & 36” 5”
SEE CHART
Cam
Lock
Cam
Lock
2-25/32”
5/32”
Drill Bit
Thread
Insert
3/4”
Hole
1/4”
Groove
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | www.midmark.com
3
Step 10:
Inside cabinet install lock bar into slots as shown.
Note: Lock bars will vary but assembly process is
the same.
Step 9:
Install lock bar onto lock bar spring.
TP200 Rev. A
003-2862-00
Step 13:
Install drawer lock bracket(s) onto drawer with provided
screw(s). Re-install drawers and test lock. Note: Numbers of
bracket(s) and screw(s) will vary with number of drawers.
Step 11:
Secure lock bar bracket onto lock bar with screw provided.
Step 12:
Re-install slides (4) with screws (4).
Lock Bar
Lock Bar
Spring
Slide
Screw
Screw
Lock Bar
Bracket
Lock Bar
Lock Bar
Drawer
Lock
Bracket
Slots
Step 8:
Use manufacture’s instructions to assemble Keyless Lock.
Note: After assembling lock, continue to Step 9 for
installation of Lock Bar.
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | www.midmark.com
4
TP200 Rev. A
003-2862-00
all
002-1973-xx Tall Cabinet Drawer Single
Keyless Lock Kit
(includes items 1 thru 10)
Item Description Qty.
1 • Lock Bar Bracket 1
2 • Screw (#10 -24 x 3/8”) 1
3 • Lock Bar Spring 1
4 • Screw (#6 x 5/8”) 2
5 Cam Lock 1
6 Press-Fit Thread Insert 1
7 Keyless Lock 1
8
RH Lock Bar
Contact Technical Service for Part Numbers
1
9 Drawer Lock Bracket - (1 per Drawer) AR
10 Screw (#10 x 5/8”) - (1 per Lock Bracket) AR
Serial Numbers / Dates:
all
050-9920-00-791 1
040-0010-109 2
025-0122-00 3
040-0006-71 4
016-1706-00 7
029-6576-00 5
050-9995-00-791 9
040-0010-48 10
042-0688-00 6
Lock Kit Used on:
002-1973-00 Tall Cabinet: 2 - 2” / 1 - 4” Drawers
002-1973-01 Tall Cabinet: 4 - 2” / 2 - 4” Drawers
002-1973-02 Tall Cabinet: All Drawers
8 a) 2-2” or 1-4” Drawer(s)
b) 4-2” or 2-4” Drawers
c) 36” (Cabinet Height)
d) 34” (Cabinet Height)
e) 30” (Cabinet Height)
© 2015 Midmark Corp. | 60 Vista Drive Versailles, OH 45380 USA | 1-800-643-6275 | 1-937-526-3662 | www.midmark.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Midmark Synthesis® Cabinetry Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI