Features
Plug & Play
Complies with IEEE802.3, IEEE802.3u, IEEE802.3ab, IEEE802.3x standards
NWAY Auto-negotiation support, Auto-Sense the transmission speed, half/full duplex
8 ports 10/100/1000M Auto-Sense, Auto-MDI/MDIX
Adopt IEEE802.3x flow control for full-duplex and backpressure for half-duplex
Non-blocking wire-speed transfer
Adopt store and forward structure
MAC address auto learning
Support IEEE802.3x for broadcasting storm control
Package Contents
One 8-Port Gigabit Switch
One Quick Installation Guide
One Power Adapter
Four rubber pad
Front Panel
LED lights panel
LED Status Operation
Power Green
Lit: Power is on
10/100M Link Green
Lit: Indicates a 10/100M device is connected
Flash: the port is transmitting/receiving data
Not lit: Indicates
there’s a 10M device or no device connected
Full Duplex
(FDX/COL)
Green
Lit: Indicates
this port is working under
full duplex mode
Flash: the port is
working under half duplex mode
Not lit: Indicates
this port is working under
half duplex mode
1000M Link/Act
Green
Lit: Indicates a 1000M device is connected
Flash: the port is transmitting/receiving data
Not lit: Indicates
there’s a 10/100M device or no device connected
Rear Panel
RJ45 ports
Side Panel
Ventilation and cooling holes
Please make sure there is no substance block up these holes, and leave enough space at the two side of
the switch, so the switch can have a proper ventilation and cooling to avoid high heat inside the switch,
which may cause improper working of the system.
Installation
1. Connect the output power to the AC-inlet of the Switch
2. Connect other IEEE802.3 compatible network device (Hub, Switch, PC) to one port of the Switch using
Category 3/4/5 UTP/STP cabling
3. Connect another IEEE802.3 compatible network device (Hub, Switch, PC) to another port of the Switch by
following the same process as described in Step2.
Caution
The surface to put the switch should be able to withstand at least 5Kgs weight
The power line should be properly and tightly connect with the switch power socket and power supply socket.
Make sure there has good ventilation around the switch; and don’t put any heavy item on the switch
Power supply requirement: 160-240VAC 50/60HZ, a good ground connection
Avoid installing the switch at high electromagnetic environment or under direct sunlight, avoiding dust and
vibrations.
Leave 10cm distance at least with other items around the switch to ensure a good ventilation and cooling.
Install the four rubber pad one the four bottom corner of the switch to avoid scratch at the bottom surface.
When install the switch on the rack, make sure to fix tight it on the rack with the screw.
The cable distance between the Switch and other IEEE802.3 compatible network device should not exceed
100 meter
Make sure the wiring is correct, it can be used Category 3/4/5 cable in 10 Mbps operation.
To reliably operate your network at 100/1000Mbps, you must use an Unshielded/shielded Twisted-Pair
(UTP/STP) Category 5 cable, or better Data Grade cabling.
While a Category 3 or 4 cable may initially seem to work, it will soon cause data loss
All kinds of IEEE802.3 compatible network device (Hub, Switch, PC)can connect to the Switch by using
straight-through wires or crossover wires because of Switch’s auto MDIX function
Troubleshooting
We always do our very best to deliver good quality product. However, the problem may still occur when you use
the product.
Most problems come from disconnected cable, faulty cable, exceeding cable length, or a malfunctioning LAN
card.
1. Check power to see if it functions properly.
Make sure the power switch is set on and the Power LED is lit. If the Power LED is not lit after the power is
turned on, check the power source and power cable. If the problem still can not be resolved, call your local
supplier to change the power adapter or the whole Switch unit.
2.Check if connection is done properly between
computers and switch or between switches.
Make sure all devices are connected to the network
properly and the Link LED is lit on each connected port.
3.Check the LAN card if it is installed properly.
4.Check the cable length, straight-through/cross-
over, collision domain limitation, and other physical aspects of the installation to see if they meet the network
installation requirements.
Notice:
If the problem still can not be solved, have your software/hardware configuration and error indications from