Ignis AKF 598 IX User guide

Category
Cookers
Type
User guide
AKF 617 PRODUCT DESCRIPTION SHEET
GB IT PT
5019 519 66010
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-
clockwise to the large flame and star
setting .
At the same time, hold the knob down until
the burner ignites.
After the burner has ignited, keep the knob
pressed down for about 10 seconds.
Release the knob.
If the burner fails to light, repeat the above steps.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the operation
with the knob turned to the small flame
setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught, an
interruption in the gas delivery, boiling over of
liquids, etc.).
3
2
1
6
5
7
8 9 10 11
4
1. Removable panstand grids
2. Auxiliary burner
3-4. Rapid burners
5-6. Semi-rapid burners
7. Auxiliary burner control knob
8. Rapid burner control knob
9. Rapid burner control knob
10. Semi-rapid burner control knob
11. Semi-rapid burner control knob
Symbols
Shaded circle tap closed
Large flame
and star
Maximum opening/
delivery and electric
ignition
Small
flame
Minimum opening
or reduced delivery
DIMENSIONS OF COOKING HOB AND
WORKTOP (mm)
NOTE: If the distance “A” between the cabinets is between 600 mm and 680 mm, the
height “B” must be a minimum of 520 mm.
If the distance “A” between the cabinets is greater than the width of the
cooktop, the height “B” must be a minimum of 400 mm.
In case of installation of a hood above the cooktop, please refer to the hood
instructions for the correct distance. In case of installation of an oven under the
cooktop, please refer to the separate oven instructions.
INJECTORS TABLE CATEGORY II2H3+
ELECTRIC SUPPLY: 230 V~ 50 Hz
Ty p e o f
gas used
Ty p e o f
burner
Injector
marking
Rated
thermal
flow rate
kW
Rated
consumption
Reduced
heat
capacity
kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
Rapid
Semi-rapid
Auxiliary
129
101
77
3.00
1.75
1.00
286 l/h
167 l/h
95 l/h
0.80
0.50
0.50
17 20 25
LIQUID
PETROLEUM GAS
(Cylinder) G30
Rapid
Semi-rapid
Auxiliary
87
66
50
3.00
1.75
1.00
218 g/h
127 g/h
73 g/h
0.80
0.50
0.50
20 28-30 35
LIQUID
PETROLEUM GAS
(Cylinder) G31
Rapid
Semi-rapid
Auxiliary
87
66
50
3.00
1.75
1.00
214 g/h
125 g/h
71 g/h
0.80
0.50
0.50
25 37 45
Type of gas used
Appliance
model 5 BURNERS
Total rated heat
capacity
kW
Total rated
consumption
Air required (m
3
) for
burning 1m
3
of gas
G20 20 mbar 5 gas 10.50 1000 l/h 21.0
G30 28-30 mbar 5 gas 10.50 764 g/h 21.0
G31 37 mbar 5 gas 10.50 750 g/h 21.0
1 / 1

Ignis AKF 598 IX User guide

Category
Cookers
Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Ask the document