WAGO-I/O-SYSTEM 750 Device Description 13
753-509 2DO 230V AC 0.3A/SSR
Manual
Version 1.1.0
Pos: 17 /A ll e Ser ien (Al lg emei ne M odul e)/Üb erschr ifte n für alle S erie n/Gerä tebes chrei bung /Gerä tebesc hreib ung - Üb ersc hrift 1 @ 3\ mod_1233756084656_21.docx @ 27096 @ 1 @ 1
3 Device Description
Pos: 18.1 .1 /Ser ie 7 53 ( WAG O-I/ O-SYST EM) /Gerä tebes chrei bung /Einlei tung /Anw endung /DO/A nwen dung 75 3-0509 @ 21\mod_1414156793438_21.docx @ 166534 @ @ 1
The I/O module 753-509 (2DO 230V AC 0.3A/SSR) uses voltages up to 230 V
AC/DC for connected actuators or universal supply voltage loads.
Pos: 18.1 .2 /Ser ie 7 53 ( WAGO-I/ O-SYST EM) /Ger äte besc hrei bu ng/Ei nlei tu ng/I/ O-B eschr eibu ng/D O/I /O-B eschr eibu ng 75x-05 xx 2 DO 2-Lei ter (D O, N ) + Fu nkti ons erde (F E) @ 21 \mod_1414156882555_21.docx @ 166538 @ @ 1
The I/O module has 2 output channels, providing a direct connection to 2
actuators with functional ground connection.
The actuators are connected to the following CAGE CLAMP
®
connectors
directly: signal output DO 1 and N or signal output DO 2 and N.
Pos: 18.1 .3 /Ser ie 7 50 ( WAG O-I/ O-SYST EM) /Gerä teb esc hrei bung /Ei nlei tung /I/O- Besc hrei bu ng/Al lg emei n/V er weis auf Kapi tel " Ansc hlüs se" @ 8\mod_1276775378035_21.docx @ 57956 @ @ 1
The assignment of the connections is described in the “Connectors” section.
Pos: 18.1 .4 /Ser ie 7 50 ( WAG O-I/ O-SYST EM) /Gerä teb eschr ei bung/ Einl eit ung/ I/O-B esc hrei bu ng/Al lg emei n/V er weis auf Kapi tel "G erät e ansc hli eßen" > "A nschl us sbei spi el(e) " @ 5\ mod_1246015203281_21.docx @ 36298 @ @ 1
Connection examples are shown in section “Connecting Devices” > … >
“Connection Example(s)”.
Pos: 18.1 .5 /S eri e 7 53 ( WAG O-I/ O-SYST EM) /Ger äte besc hrei bu ng/Ei nlei tu ng/I/ O-B eschr eibu ng/D O/I /O-B eschr eibu ng 753-0 509 H oc hleis tu ngs- MOSF ETs @ 2 1\mod_1414157149384_21.docx @ 166542 @ @ 1
As a switching relay, there are two high-performance MOSFETs in the I/O
module. The actuators can be mechanically controlled continuously and free of
wear from the I/O module's semiconductor outputs. The MOSFETs are non-
isolated, i.e., the potential for the field supply touches one of the relay contacts (0
V … 230 V AC/DC).
Pos: 18.1 .6 /Ser ie 7 50 ( WAG O-I/ O-SYST EM )/G eräte bes chr eibu ng/Ei nlei tu ng/I/ O-B esc hrei bung /DO /I/O- Besc hrei bung 75 0-0509 Sc hließ er-Rel ai s @ 12\mod_1339505334211_21.docx @ 96985 @ @ 1
When a relay is closed, the field potential applied is then routed to the associated
second relay contact DO 1 or DO 2.
Pos: 18.1 .7 /Ser ie 7 50 ( WAG O-I/ O-SYST EM )/G erä teb esc hrei bu ng/Ei nlei tu ng/V ers org ung/ Ans teu eru ng d er H albl ei ter ausg äng e @ 12\mod_1339505784466_21.docx @ 97019 @ @ 1
Control of the semiconductor outputs is fully isolated.
Pos: 18.1 .8 /Ser ie 7 50 ( WAG O-I/ O-SYST EM )/G eräte bes chr eibu ng/Ei nlei tu ng/L ED-A nz eige/ LED Zu stan d R elais @ 5\mod_1246862048946_21.docx @ 36603 @ @ 1
The switching status of the two relays is indicated via green status LEDs.
Pos: 18 .1.9 /S erie 750 (WAGO-I/ O-S YSTEM )/G erä teb eschr ei bung/ Einl eit ung/ LED-A nzei ge/Ver weis auf Kapi tel "Anz eige elem ente" @ 5\ mod_1246010525000_21.docx @ 36194 @ @ 1
The meaning of the LEDs is described in the “Display Elements” section.
Pos: 18.1 .1 0 /S erie 750 ( W AGO -I/O-SY ST EM)/Wi chti g e Erl äu ter ung en/Si cher hei ts- und s ons tig e Hi nw eise /Hin wei s/Hi n weis : Ei nspei se kle mme für Ver sorg ung ung leic h 24 V ei nsetz en @ 5\ mod_1247032609340_21.docx @ 36784 @ @ 1
Use additional supply module!
Use an additional supply module if I/O modules require a field supply not equal to
24 VDC. Insert the supply module in front of the module that requires the
different supply.
Pos: 18.1 .1 1 /S erie 753 ( W AGO -I/O-SY ST EM)/G eräte beschr eib ung/Ei nleit ung/ Versor gung /Vers orgung AC/DC 0. ..23 0 V, N und Er de über Leistu ngs kontakt e @ 21\mod_1414157661006_21.docx @ 166546 @ @ 1
The I/O module receives the 0 V ... 230 V AC/DC power supply, the N potential
and the ground potential for the field level from an upstream I/O module and
makes the potentials available to subsequent I/O modules via the power jumper
contacts designed as spring contacts.
Pos: 18.1 .1 2 /S erie 750 ( W AGO -I/O-SY ST EM) /Wic htig e Er l äuter ung en /Sic her hei ts- un d s onsti ge H in wei se/Ac htung /Acht ung: Maximal er Str om Leis tungs konta kte 10 A @ 3\ mod_1226499143500_21.docx @ 25029 @ @ 1
Do not exceed maximum current via power jumper contacts!
The maximum current to flow through the power jumper contacts is 10 A.
Greater currents can damage the contacts.
When configuring your system, ensure that this current is not exceeded. If
exceeded, insert an additional supply module.
Pos: 18.1 .1 3 /S erie 750 ( W AGO -I/O-SY ST EM)/ Gerät ebe schr eib ung/ Einl eit ung/ Ein satz berei ch/ Ein satz berei ch 7 50-xxxx all e Ko ppl er/C o ntroll er oh ne Ei nsc hrä nku ng @ 3\ mod_1232541691906_21.docx @ 26522 @ @ 1
The I/O module 753-509 can be used with all fieldbus couplers/controllers of the