Hyundai Poseidon User manual

Type
User manual
O F F I C E M A N U A L
7
P I Z Z A P I Z Z A
RESETING THE HUB
This is the most common or frequently used dial-up modem in most Pizza Pizza stores, models
may be different
Power input
Power input
Power input
3. Insert the power cable back into the power input.
2. Insert the power cable back into the power input.
1. Unplug the power cable form the power input.
hyundai manual_8.indd 2-3 3/26/07 1:46:59 AM
UNPACKING
2
1. Unpack the unit by CUTTING the STRAPS from the box.
STRAPS
3. Visually INSPECT the unit body to check for any dAmAGE that may have occurred
during transportation and, if any, NOTIfy your dealer immediately.
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
HYUNDAI water purifiers are shipped completely assembled and ready to be connected
to water source, water outlet and electricity.
2. Slide the box UPwARd to clear the top.
SANITATION
1. UNSCREw and REmOVE the TOP SHElf PlATE of the POU to UNCOVER the reservoir.
2. UNSCREw and REmOVE the TOP TANK COVER to ExPOSE the reservoir tank.s
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
In order to maintain the cleanliness of the POU, it is important to sanitize the tank using
a hydrogen peroxide-based food-grade cleaner such as AQUADOSA© or ZEPAMINE©
TOP SHELF PLATE
3
SCREW
TANK COVER
SCREW DRIVER
CLEANER
hyundai manual_8.indd 6-7 3/26/07 1:47:00 AM
4. Follow the FOOD-GRADE cleaner instructions very carefully to sterilize reservoirs.
2. DRAIN the reservoirs by using the RESERVOIR DRAIN LINES in the BACK of the POU
(located behind the front panel in the POSEIDON model – see Flushing for exact
picture and location)
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
SANITATION - CONT’D
4
* Hyundai recommends letting the cleaner solution sit for 6 hours to overnight if possible
in order to fully sanitize the reservoirs AND to check for leaks that may occur from
any tubing and fittings. This is a vital part of maintenance service for the POU and helps
extend the life of the machine. It is recommended to sanitize at least 2-3 times a year.
CONNECTING TO WATER SUPPLY
1. TWO (2) Valve Piercing Saddle Clamps
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
Hyundai Water Purifiers are designed to connect to any home or office water source.
The preferable water source is the water inlet pipe located near a sink.
VALVE PIERCING
SADDLE CLAMPS
5
Hyundai Water Purifiers come equipped with enough tubing so that there is flexibility on
the location of the Water Purifier
You will need the following:
WATER INLET PIPE
TUBING
STRAPS
hyundai manual_8.indd 8-9 3/26/07 1:47:02 AM
6
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
2. T-connector (also referred to as ‘T-Joint Adapter’)
3. Basin Wrench
1. Close the water going to the water inlet pipe using the dIAl VAlVE. as well as the
wATER dRAIN PIPE.
2. Fit the NUT on the tube.
NUT
INSTAllATION
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
3. THREAd the TUBE through the NUT.
Destination options
4. Attach NUT to T-CONNECTOR.
TUBE
T - CONNECTOR
7
T - CONNECTOR
BASIN WRENCH
DIAL VALVE
TUBE
hyundai manual_8.indd 10-11 3/26/07 1:47:03 AM
5. Tighten top of SADDLE CLAMP onto NEEDLE-VALVE.
SADDLE CLAMP
COUPON button
6. Place the FOAM RUBBER GASKET under the top of the SADDLE CLAMP.
7. Using the screws, TIGHTEN the bottom of the SADDLE CLAMP between the WATER INLET
PIPE and the top of the SADDLE CLAMP.
8. SCREW the NEEDLE-VALVE to pierce the WATER INLET PIPE.
RUBBER WASH
SCREWS
8
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
1 DRAIN SADDLE CLAMP
1. Using a 5/16 DRILL BIT, drill a hole on the area ABOVE THE DRAIN PIPE trap.
CONNECT TO DRAIN
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
2. ALIGN the FOAM RUBBER GASKET with the DRILLED HOLE.
3. Using the screws and washers, TIGHTEN the SADDLE CLAMP onto the DRAIN PIPE.
9
You will need the following:
SADDLE CLAMP
WATER INLET PIPE
DRILL BIT
FOAM RUBBER GASKET
DRILLED HOLE
SADDLE CLAMP
SCREWS
hyundai manual_8.indd 12-13 3/26/07 1:47:04 AM
1. THREAd the TUBE through the NUT leaving approximately 2 INCHES of tubing in the ClAmP.
2. INSERT TUBE into the ClAmP and TIGHTEN the wASHER.
2. ATTACH tubing through the SIdE BACK PANEl and ‘quick-co nect to SEdImENT fIlTER and
begin Flushing the filters.
1 0
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
CONNECT TO dRAIN - CONT’d
flUSHING
1 1
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
* It is required that the filters be flushed once for three minutes prior to the system being
used. This process will reduce accumulation of black “carbon fines” finding their way
into the storage tanks and ultimately into the customers drinking glass.
You do NOT require the POU to be turned on to flush the filters!
IN ORdER TO ACCESS THE fIlTERS, THE fRONT PANEl mUST BE REmOVEd. dEPENdING ON
THE mOdEl, yOU CAN REmOVE THE fRONT PANEl By ONE Of THE fOllOwING:
fOR mOdElS: w2-310l, ROmEO-1, JUlIET-1, w2-360, w2-360E.
1. Open the front panel by lIfTING OUT the CATCH TRAy,
2. Undo the TwO SCREwS under the TRAy that hold the lower front panel.
3. TIlT the unit BACKwARd about 10 dEGREES and remove the front panel by gently pulling
it dOwN and then OUT.
TUBE
WASHER
TUBING
CATCH TRAY
SCREWS
FRONT PANEL
a
p
p
r
o
x
1
0
˚
PULL PANEL DOWN AND OUT
hyundai manual_8.indd 14-15 3/26/07 1:47:05 AM
1 2
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
fOR mOdElS: w2-340, w2-340E, w2-340S,
1. Open the front panel by PUllING OUT the CATCH TRAy.
2. UNdO the TwO SCREwS under the TRAy that hold the lower front panel.
4. Carefully set front panel to the side in a safe place to prevent scratching or breaking.
3. TIlT the unit BACKwARd about 10 dEGREES and remove the front panel by gently pulling
it dOwN and then OUT.
4. Carefully set front panel to the side in a safe place to prevent scratching or breaking.
fOR mOdEl: POSEIdON
1. lIfT the catch basin OUT of the unit
2. Remove the lOwER fRONT PANEl by gently PUllING it out by the UPPER CENTER.
3. Carefully set front panel to the side in a safe place to prevent scratching or breaking.
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
1 3
fOR mOdElS: SPR-3011 ANd SPR-4011
1. lIfT the CATCH BASIN out of the unit.
CATCH TRAY
SCREW
TRAY
CATCH BASIN
LOWER FRONT PANEL
CATCH BASIN
FRONT PANEL
a
p
p
r
o
x
1
0
˚
PULL PANEL DOWN AND OUT
hyundai manual_8.indd 16-17 3/26/07 1:47:06 AM
1 4
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
2. Remove the lower front panel by gently PUllING IT OUT by the UPPER CENTER
3. Carefully set front panel to the side in a safe place to prevent scratching or breaking.
ese are the filters that require flushing. ey should all be flushed one at a time for a
minimum of 3 minutes each prior to allowing water to run to the storage tank.
1. Each filter is marked with an arrow which denotes the orientation of the
filter being flushed. Attach water feed to the INCOmING wATER ElBOw of
the Filter you are flushing.
2. Turn on valve allowing influent water to run thru filter for 3 mINUTES or until clear
water runs for at least 30 seconds. We suggest allowing water to run in a white
plastic bucket or sink to allow you to see when it runs clear.
3. Place filter back inside unit, reconnect tubing, move on to next filter and repeat
until all filters have been flushed.
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
1 5
Please note that you may need to re-use the connection elbows if you are replacing
existing filters with new ones.
SEDIMENT FILTER
PRE-CARBON FILTER
POST-CARBON FILTER
LOWER FRONT PANEL
CONNECTION ELBOW
REVERSE OSMOSIS
FILTER
ARROW ORIENTATION
hyundai manual_8.indd 18-19 3/26/07 1:47:08 AM
ANAlOG HOT ANd COld wATER PURIfIER CONTROlS
2 0
After installing the POU and connecting power and water supply, turn on the red switch
in the back of the machine. e cold water “set as default can be adjusted by turning the
green dial labeled COld.
mAINTENANCE & INSTAllATION TIPS:
After the tanks are full and the hot and cold temperatures reached, the water is ready for
consumption.
Pre-flush filters prior to allowing water to migrate to the storage tanks.
Allow each system to process water to full capacity at least 2 times and completely flush
system before moving to customer location.
Carefully inspect all filters and tubing connections for leaks prior to final installation.
When transporting to installation location, be sure to do so, using all packaging unit was
shipped with.
NEVER lay unit down on its side, it is recommended not to tilt unit more than 15 degrees
prior to installation. If unit is tilted more than 15 degrees, unit should stand in vertical
position for 24 hours prior to installation.
Connect directly to electrical outlet; DO NOT use an extension cord!
After unit is properly connected to water and power, it is advisable to remain with unit for
approximately 30 minutes to observe start-up. Fittings can become loose or stressed dur-
ing transportation. Be sure to give a final check of all connections prior to walking away
from your installation for best results.
Reverse-Osmosis units produce water at a reduced and varying rate of production as com-
pared to micro or ultra filtration systems.
Time to fully satisfy the storage capacity of these systems will depend on the unit you are
installing, water pressure and the quality of the water you are purifying.
fAQ
1) THE wATER IS NOT COld ENOUGH.
Have you used too much cold water recently?
Your purifier has a specific cold and/or additional reservoir capacity so please wait a
sufficient period of time before reuse.
Have you checked the voltage of your Purifier?
Your Purifier operates at 110 V. Please do not operate at any other voltage.
Is the back panel of the purifier too close to the wall?
Certain components of your purifier cause heat and the POU should not be too close
to the wall or other structure.
Is the Purifier in direct sunlight or near a heat source?
Please move your product to another location away from the heat source.
Is the temperature of the water supply appropriate?
e water feed temperature should be less then 86°F (30°C).
2) THE wATER IS NOT HOT ENOUGH.
Have you used too much hot water recently?
Please wait a sufficient period of time before re-use.
Is the hot water switch set to ‘off ’?
e hot water switch is located on the back panel of the purifier; please ensure it is
set to ‘on’.
Is the water supply adequate?
Insufficient supply of water could be the reason – ensure the tank is filled with water.
3) THE wATER PURIfIER IS NOT fUNCTIONING PROPERly.
Is this a power failure?
Please check the power supply with other electrical appliances. Also check if the fuse
is disconnected or burnt. Please consult with an electrician for replacement.
Is the purifier emitting an irregular sound?
Please ensure the area of installation is flat and solid.
e purifiers may emit a vibration upon a first install and this is completely
normal as the auto-shut-off valve is under pressure. After the initial install and flush
is done, this sound will be minimized.
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
2 1
hyundai manual_8.indd 24-25 3/26/07 1:47:11 AM
fAQ CONT’d
4) ere is an unpleasant taste or strange odor.
Have you replace the filters recently?
Replace the Post Carbon Filter (4th in sequence) and clean the water tank by empty-
ing the reservoir tanks (via drain tubes located on either the front or back of the
unit). If the taste or odor persists, replace all filters.
5) Particles in water are appearing as salt or ice.
Please discharge all water from the reservoir tanks and consult your Dealer.
6) ere seems to be a water leakage.
Turn off the unit. Check the condition of the quick-connect hoses from filter to filter
and tighten or adjust where necessary. Also check the lines from the reservoir tanks.
Please consult with your Dealer if leaking persists.
4) ere is an unpleasant taste or strange odor.
Have you replace the filters recently?
Replace the Post Carbon Filter (4th in sequence) and clean the water tank by empty-
ing the reservoir tanks (via drain tubes located on either the front or back of the
unit). If the taste or odor persists, replace all filters.
5) Particles in water are appearing as salt or ice.
Please discharge all water from the reservoir tanks and consult your Dealer.
6) ere seems to be a water leakage.
> Turn off the unit. Check the condition of the quick-connect hoses from filter to
filter and tighten or adjust where necessary. Also check the lines from the reservoir
tanks. Please consult with your Dealer if leaking persists.
H Y U N D A I W A T E R
W A T E R P U R I F E R S Y S T E M
2 2
hyundai manual_8.indd 26-27 3/26/07 1:47:11 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Hyundai Poseidon User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI