EDWARDS CS405 is a high-quality notification appliance intended for public mode applications. It is suitable for indoor or outdoor use, making it a versatile choice for various settings. A weatherproof backbox is required for outdoor installation. The device is self-synchronized to flash at 1 fps across its full operating voltage range. Synchronization of less than 200 milliseconds will be maintained for no less than 60 hours supervision followed by 30 minutes in alarm.

EDWARDS CS405 is a high-quality notification appliance intended for public mode applications. It is suitable for indoor or outdoor use, making it a versatile choice for various settings. A weatherproof backbox is required for outdoor installation. The device is self-synchronized to flash at 1 fps across its full operating voltage range. Synchronization of less than 200 milliseconds will be maintained for no less than 60 hours supervision followed by 30 minutes in alarm.

Installation Instructions for Strobe Signal Appliance
1. For indoor mounting, select a Standard North American 2 gang X 1-1/2"
(38 mm) deep electrical box (52151 Series or equivalent). For outdoor
mounting, use a weatherproof model 449 backbox. Install the electrical
box using suitable hardware.
2. Bring signaling circuit field wiring into the electrical box.
CACA
CACA
CA
UTION:UTION:
UTION:UTION:
UTION: Electrical supervision requires wire run to be broken at each
device. Do not loop signaling circuit field wires around terminals.
3. Connect this unit to a signaling circuit that outputs a constant (not
pulsed) voltage. To ensure proper unit function, polarity must be
observed. Refer to Figure 2 for wiring connections. For additional
wiring connection details, see the installation instructions supplied with
the control panel.
4. When connections are complete, mount the unit onto the electrical box as
follows:
a. For indoor mounting, secure the unit using two Phillip head screws
(supplied). Complete the enclosure by installing two hole plugs
(Part Number P-038845-0019 (supplied)) into the two unused holes
in the back plate.
b. For outdoor mounting, secure the unit using the four Phillip head
screws (supplied). Discard the two plastic caps (supplied).
5. Apply power and activate the unit to verify that it is operating properly.
MAINTENANCE
CACA
CACA
CA
UTION:UTION:
UTION:UTION:
UTION: Should the unit fail to operate properly, do not attempt repair.
Contact the supplier for replacement.
Perform a visual inspection and an operational test twice a year or as directed
by the local authority having jurisdiction.
DESCRIPTION
The strobes are high quality notification appliances intended for public
mode applications in accordance with the latest edition of NFPA 72,
National Fire Alarm Code. It is recommended that these products be
installed in accordance with the requirements in the latest edition of
national and local fire alarm and electrical codes. The 15/75 cd model and
the 110 cd model strobes are suitable for indoor or outdoor applications.
For outdoor use, the strobes must be installed with a weatherproof
backbox, model 449.
The strobes are self-synchronized to flash at 1 fps across their full
operating voltage range. Studies show that people with photosensitive
conditions may experience a photoconvulsive response from random
flashes of light. This risk is minimized with these strobes. The strobe
operates on any existing 2-wire signal circuit. Separately installed "sync
control modules" are not required.
Synchronization of less than 200 milliseconds will be maintained for no
less than 60 hours supervision followed by 30 minutes in alarm.
See Figures 3 and 4 for product specifications.
INSTALLATION
WW
WW
W
ARNING:ARNING:
ARNING:ARNING:
ARNING: This device will not operate without electrical power. As fires
frequently cause power interruptions, discuss further safeguards with your local
fire protection specialist.
To reduce the risk of shock, always disconnect all power before handling
the unit.
To reduce the risk of shock, do not tamper with unit when circuit is energized.
Disconnect all power and allow 5 minutes for stored energy to dissipate
before handling.
P/N 387627 © 1996
*
*
-
End-of-line resistor
(supplied with control panel)
+
-
CAUTION: This unit is designed to be used on signal circuits that output a constant voltage of 20-24 VDC. Do not connect this unit to a coded or
pulsating voltage. Electrical supervision requires wire run to be broken at each terminal. Do not loop signaling circuit field wires around strobe terminals.
Figure 2. Connecting Strobe Units with Terminal Blocks
To Listed Fire Alarm
Control Panel (signal
circuit)
SIDE VIEW,
WALL MOUNTED
FRONT VIEW,
WALL MOUNTED
SIDE VIEW,
CEILING MOUNTED
*Text offered in various styles and languages. Order either the
LKC Series (Ceiling) or LKW Series (Wall) Lens Kit Separately.
LKW-1 ("FIRE", wall orientation) is supplied with the strobe.
Figure 1. Detailed View
SPECIFICATIONS
Operating voltage: 20-24 Vdc
Operating current: See figure 3
Flash rate (per second) 1 fps (synchronized)
Light output (cd)
UL 1971 -7A: 15 cd wall UL 1971 - 8A: 110 cd wall
15 cd ceiling 60 cd ceiling
UL 1638 - 7A: 75 cd UL 1638 - 8A: 120 cd
Operating environment
Indoor 85% relative humidity @ 86 °F (30 °C), 32 °F to 120 °F
(0 °C to 49 °C) variable ambient temperature
Outdoor 93% relative humidity @ 86 °F (30 °C), -40 °F to 151 °F
(-40 °C to 66 °C) variable ambient temperature (with
weatherproof box)
NOTE: The 8A strobe may be used in sleeping areas. When used in sleeping
areas, the strobe must be wall mounted not less than 24 in. (601 mm) from ceiling
and no more than 16 feet (4.88 m) from the pillow. Distance to the ceiling is
measured from top of signal lens.
Figure 3. V/I Curves
110 cd Model
NOTE: Use the average current rating to establish the maximum number of strobes, wire gauge and standby power requirements. Consult the
manufacturer to determine the peak current effects on the system.
910
900
890
870
828
220
210
200
190
235
370 363
357
330
385
150
250
350
450
550
650
750
850
950
20 21 22 23 24
Operating Voltage Full Wave Rectified
Operating Current (mA)
265
219
235
245
260
340
315
325
330
335
200
225
250
275
300
325
350
20 21 22 23 24
Operating Voltage DC
Operating Current (mA)
Iavg
Irms
Ipeak
Peak Inrush Current @ 24 Vdc = 7.8 A for
less than 50 microseconds.
Peak Inrush Current @ 24 Vdc = 6.8 A for
less than 50 microseconds.
GENERAL SIGNAL BUILDING SYSTEMS CORPORATION
SARASOTA , FL 941-739-4300 Fax. 941-753-1806
CHESHIRE, CT 203-699-3000 Fax. 203-699-3075
Figure 4. Strobe Light Output Distribution Patterns
UL Minimum
Requirement
Typical Output
90
O
90
O
-90
O
HORIZONTAL
VERTICAL
-90
O
0 25 50 75 100 125 150 175
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Θ
(cd)
0 25 50 75 100 125 150 175
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Θ
(c d )
0
25
50
75
10 0
12 5
15 0
Θ
110 cd
Model
Horizontal
Ceiling
Vertical
NOTE: This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to correct the
interference at his own expense.
CAUTION: Changes or modifications to this equipment not expressly approved by
the party responsible for compliance could void the users authority to operate the
equipment.
Electronic strobes
CS405-7A-T Electronic strobe, 15/75 cd red
CS405-8A-T Electronic strobe, 110 cd red
530
526 524
522 520
98
94 92
90
102
186 18 1
177
172
190
50
150
250
350
450
550
20 21 22 23 24
Operating Voltage Full Wave Rectified
Operating Current (mA)
125
105
113
116
124
185
165
170
175
180
100
125
150
175
200
20 21 22 23 24
Operating Voltage DC
Operating Current (mA)
15/75 cd Model
Peak Inrush Current @ 24 Vdc = 7.6 A for
less than 50 microseconds.
Peak Inrush Current @ 24 Vdc = 6.8 A for
less than 50 microseconds.
0
20
40
60
80
Θ
15/75 cd
Model
0 1020304050607080
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Θ
(c d )
0 1020304050607080
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Θ
(c d )
P/N 387627 © 1996
OWEN SOUND, CANADA 519-376-2430 Fax. 519-376-7258
INTERNATIONAL: CANADA 905-270-1711 Fax. 905-270-9553
  • Page 1 1
  • Page 2 2

EDWARDS CS405 Installation guide

Category
Fire protection
Type
Installation guide

EDWARDS CS405 is a high-quality notification appliance intended for public mode applications. It is suitable for indoor or outdoor use, making it a versatile choice for various settings. A weatherproof backbox is required for outdoor installation. The device is self-synchronized to flash at 1 fps across its full operating voltage range. Synchronization of less than 200 milliseconds will be maintained for no less than 60 hours supervision followed by 30 minutes in alarm.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI