Lithonia Lighting BLT4 BLT Best In Value Low Profile LED Luminaire Owner's manual

Type
Owner's manual
FEATURES & SPECIFICATIONS
INTENDED USE
The RELOC®-Ready Luminaire (RRL) connectors enables a simple and consistent factory installed
option across all ABL luminaire brands. When ordered on a RELOC xture cable (OFC), xture cord
drops (OCS or OCU) and xture drop cables (OD); the line side of the connector will be factory attached
to all the wire leads except for the ground wire. When ordered with the luminaire, the load side of the
connector will be prewired based on the appropriate wiring instruction selection.
ELECTRICAL
18 AWG solid wire only; stranded not available.
Tin-bonded 18 AWG (≤16 strand) acceptable.
Current Interruption 10 cycles.
SYSTEM FEATURES
RRL connector used with the OnePass system.
Load side of connector factory attached to luminaire. Refer to luminaire spec sheet for ordering
information.
4-pole mating connector with push-in terminations allows for simple installation.
Touch-safe design on both halves, meets UL/CSA requirement.
Wiping contact design allows safe disconnect under load.
LISTINGS
UL 2459
CSA- C22.2 NO. 2459
NEC 2008 410.130(G) Compliant
CEC 30-308(4) Compliant
1 of 1
Catalog Number
Notes Type
One Lithonia Way Conyers, GA 30012 Phone: 800-241-4750 www.relocwiring.com [email protected] © 2013-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/29/18
RELOC®-Ready Luminaire
RRL
Universal Fixture Connector
RRL Load Side shown
OD with RRL line side shown OFC with RRL line side shown
RRL
Series Wiring Instructions
ABallast/driver wired to pin position #1 (120V,277V,347V - Phase A)
Ballast/driver wired to pin position #1 & #4 (208V, 240V, 480V - Phase A)
BBallast/driver wired to pin position #2 (120V,277V,347V - Phase B)
Ballast/driver wired to pin position #2 & #4 (208V, 240V, 480V - Phase B)
CBallast/driver wired to pin position #3 ( 120V,277V,347V - Phase C )
AB Outboard ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) 2
Inboard ballast/driver wired to pin position #2 (120V, 277V, 347V - Phase B)
AE Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A)
Emergency ballast/driver wired to pin position #2 (120V,277V,347V - Phase B) 3
ABE Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) 2
Ballast/driver wired to pin position #2 (120V,277V,347V - Phase B)
Emergency ballast/driver wired to pin position #3 (120V,277V,347V - Phase C) 3
C12S Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A)
Low voltage wire (positive/purple) (data1) wired to pin position #2
Low voltage wire (common/gray) (data2) wired to pin position #3 4
Ballast/driver wired to pin position #1 & #2 (208V, 240V, 480V - Phase A) 4
Low voltage wire (positive/purple) (data1) wired to pin position #2
Low voltage wire (common/gray) (data2) wired to pin position #3 4
22N Ballast/driver wired to pin position #2 and pin position #3 (120V,277V,347V - Phase B)
122N Ballast/driver wired to pin position #1 and #4 (120V,277V,347V - Phase A)
Ballast/driver wired to pin position #2 and #3 (120V,277V,347V - Phase B)
RRL1
RoHS Compliant
WARRANTY
5-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Actual performance may dier as a result of end-user environment and application.
Note: Specications subject to change without notice.
Load Side RELOC®-Ready Luminaire
NOTES
1. Not available with IBG Haleon sensor options.
2. Not available with LED luminaries. Only compatible with products that are wired
for outboard/inboard control.
3. AE and ABE Commercial xtures should disconnect the TSPL before unplugging
the RRL so it does not go into discharge mode.
4. RRLC12S option is to be used with the OnePass OCU, OCS, OD, OFC and OD for 0-24V
integrated single-circuit or 0-10V low voltage controls applications. Not available
with integral dimming sensors.
Fixture Ordering Example:
IBG 15000LM SEF AFL GND 277 GZ10
40K 80CRI PS30250 RRLAE BPK DWH
FIXTURE ORDERING LOGIC
For shortest lead times, congure product using bolded options.
Line Side RELOC®
Series
RRL
RELOC® Ordering Example:
OFC 277 12/2G 13 RRL G
OCS 480 10 RRL
OD 277 12/3G 15 RRL
RRL
NOTE
1. All hot conductors and neutral wires present in RELOC cable, drop
cable.
2. G option required for OFC xture cables.
3. Ground wire will include poke-in wire connector.
4. Visit RELOC® to order with RELOC systems.
2 of 2
RRL RELOC®-Ready Luminaire
RRL
Position # Function
Standard Wiring Applications
120V,277V,347V
1Hot 1 X X
2Hot 2 X X
3Hot 3 X
4Neutral XXXX
Wiring Instruction RRLA RRLB RRLC RRLAB
DIMENSIONS
Dimensions are shown in inches (millimeters)
LOAD SIDE
Connects to Fixture. Installed on
xture at factory or by customer.
LINE SIDE
Connects to RELOC Fixture Cable.
Installed on Reloc cable at the factory.
WIRING INSTRUCTIONS
Pin position and conductor functions by voltage.
Position # Function
Normal and Emergency
Applications 120V, 277V, 347V
1Hot 1 X X
2Hot 2 X X
3Hot 3 X
4Neutral X X
Wiring Instruction RRLAE RRLABE
Position # Function
Class I Class II Wiring Ap-
plications 120V, 277V
1Hot 1 X
2 Data 1, Positive ( + ) X
3 Data 2, Common ( - ) X
4Neutral X
Wiring Instruction RRLC12S
Position # Function
Two Neutral Applications
120V, 277V, 347V
1Hot 1 X
2Hot 2 X X
3 Neutral 2 X X
4Neutral 1 X
Wiring Instruction RRL22N RRL122N
Position # Function
Special Industrial Voltage
Applications 208V, 240V, 480V
1Hot 1 X
2Hot 2 X
3Hot 3
4Hot 4 X X
Wiring Instruction RRLA RRLB
Position # Function
Class I Class II Wiring
Applications 208V, 240V, 480V
1Hot 1 X
2 Data 1, Positive ( + ) X
3Data 2, Common ( - ) X
4Hot 2 X
Wiring Instruction RRLC12S
One Lithonia Way Conyers, GA 30012 Phone: 800-241-4750 www.relocwiring.com [email protected] © 2013-2018 Acuity Brands Lighting, Inc. All rights reserved. Rev. 11/29/18