Cumberland Actuated Large Ceiling Inlet is a versatile and efficient ventilation solution for large indoor spaces, such as warehouses, factories, and agricultural buildings. Its innovative design and advanced features provide optimal airflow control, energy efficiency, and ease of installation.

The inlet's robust construction ensures durability and longevity, while the adjustable opening allows for precise airflow regulation. The included insulation stop helps prevent heat loss, contributing to energy savings.

The inlet's actuation mechanism enables remote control of the airflow, allowing for automated ventilation based on specific temperature or humidity conditions. This feature optimizes ventilation efficiency and reduces energy consumption.

Cumberland Actuated Large Ceiling Inlet is a versatile and efficient ventilation solution for large indoor spaces, such as warehouses, factories, and agricultural buildings. Its innovative design and advanced features provide optimal airflow control, energy efficiency, and ease of installation.

The inlet's robust construction ensures durability and longevity, while the adjustable opening allows for precise airflow regulation. The included insulation stop helps prevent heat loss, contributing to energy savings.

The inlet's actuation mechanism enables remote control of the airflow, allowing for automated ventilation based on specific temperature or humidity conditions. This feature optimizes ventilation efficiency and reduces energy consumption.

Date: 03-16-23 V3.0 PNEG-2385
Instructions
1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421
PNEG-2385
Page 1 of 9
Printed in the USA
Copyright © 2023 by The GSI Group, LLC
www.automatedproduction.com /
www.cumberlandpoultry.com
CN-409048
Actuated Large Ceiling
Inlet Installation
Installing the Actuated Large Ceiling Inlet (ACI-2-2828-KIT)
1. Frame rough opening in the ceiling for each inlet.
2. Staple the insulation stop (29) to the frame’s opening (35), making sure it is flush with the bottom side
of the frame opening (35). (See Figure 1.)
Figure 1 Securing the Installation Stop
3. Center the inlet (30) within the framed opening (35). (See Figure 2.)
4. Attach the inlet (30) to the frame opening (35) using eight #10 x 1-1/2" SMSA screws (6).
NOTE: Use a 1/4" hex head drive to install the screws (6). The locations (38) to install the screws (6)
are marked on the inlet (30) frame with a boss.
Figure 2 Installing the Inlet to the Frame Opening
Model Rough Opening Description
ACI-2-2828-KIT 27-1/2" x 27-1/2" With the Insulation Stop
ACI-2-2828 27-3/8" x 27-3/8" Without the insulation Stop
Ref # Description
29 Insulation Stop (30-1383)
35 Frame Opening (27-1/2" x 27-1/2")
Ref # Description Ref # Description
6#10 x 1-1/2" SMSA Screw (S-10819) 35 Frame Opening
30 Inlet Assembly (ACI-2-2828-KIT) 38 Screw Locations
Page 2 of 9 PNEG-2385
Actuated Large Ceiling Inlet Installation
5. Run the 1/8" rods (36) through the inlet (30).
a. If using one rod (36), run it through the center hole in the inlet (30).
b. If using two rods (36), run them through the outside holes in the inlet (30).
6. Fasten the nylon cords (31) to the 1/8" rods (36) using 1/8" cable clamps (32). Place the cable
clamps (32) as close as possible to the inside wall of the inlet (30).
NOTE: Cable clamps (32) must be at least 18" from the center of the inlet (30) to allow for full range
of operation.
7. Thread the nylon cord (31) through the stationary pulley (11) then down through the door (18).
NOTE: Make sure the nylon cord (31) goes around the stationary pulley (11) as shown in Figure 3.
8. Close the door (18) and slide the plastic ball (33) onto the nylon cord (31), then fasten closed with
azuma nut (34).
9. Cut-off the excess nylon cord (31), leaving 3"-4" below the azuma nut (34) for adjustment.
NOTE: The nylon cord (31) will stretch. Re-adjust the azuma nut (34) as needed to keep the
door (18) closed.
Figure 3 Attaching the Nylon Cords to the Door and Rod
Ref # Description Ref # Description
11 Stationary Pulley (30-1277) 32 1/8" Cable Clamp (S-8946)
18 Door (30-1370) 33 Plastic Red Ball (FLX-2442)
30 Inlet Assembly (ACI-2-2828-KIT) 34 Plastic Azuma Nut (35-0018)
31 Nylon Cord (35-0118) 36 1/8" Rod
30
18
33
34
18
33
34
32
31
36
31
30
32
32
31
36
36
31
11
11
One rod
Two rods
18" min. from
center to cable clamp
18" min. from
center to cable clamps
Benefits of two rods controlled ACI inlets:
1. Close half of the doors without having to
close them by hand.
2. Stagger inlets rigging.
• Open-close both doors on ever other inlets
in a row.
3. Alternate door rigging.
• Independently open-close doors on an inlet.
4. Create the air flow zones in a room or
building.
PNEG-2385 Page 3 of 9
Actuated Large Ceiling Inlet Installation
10. Pull the rubber latches (14) into the door locks (37) if you do not want the doors (18) to open when
actuated.
Figure 4 Locking the Doors
Inlet Configurations
Figure 5 Possible Inlet Door Setups
Ref # Description
14 Rubber Inlet Latch (30-1202)
18 Door (30-1370)
37 Door Lock
Cable B
Alternating inlet setupStaggered inlet setup
Cable A
Cable A connects to Left Door.
Cable B connects to Right Door.
Cable A connects to Right Door.
Cable B connects to Left Door.
Cable A connects to Right Door.
Cable B connects to Left Door.
L - Left Door
R - Right Door
Cable A connects to Left Door.
Cable B connects to Right Door.
Both doors are connected
to Cable A.
Both doors are connected
to Cable B.
Both doors are connected
to Cable A.
Both doors are connected
to Cable B.
Cable B
Inlet #1 Inlet #1
RL
RL
RL
RL
RL
RL
RLRL
Inlet #2 Inlet #2
Inlet #3 Inlet #3
Inlet #4 Inlet #4
Cable A
Page 4 of 9 PNEG-2385
Actuated Large Ceiling Inlet Installation
Pulley Layouts
Figure 6 Possible System Layout
End Installation - One Row of Inlets (2 to 1)
Figure 7
PNEG-2385 Page 5 of 9
Actuated Large Ceiling Inlet Installation
Middle Installation - One Row of Inlets (2 to 1)
Figure 8
Page 6 of 9 PNEG-2385
Actuated Large Ceiling Inlet Installation
End Installation - Two Rows of Inlets (2 to 1)
Figure 9
PNEG-2385 Page 7 of 9
Actuated Large Ceiling Inlet Installation
Middle Installation - Two Row of Inlets (2 to 1)
Figure 10
Page 8 of 9 PNEG-2385
Actuated Large Ceiling Inlet Installation
Ceiling Inlet Assembly Parts (ACI-2-2828-KIT)
PNEG-2385 Page 9 of 9
Actuated Large Ceiling Inlet Installation
Ceiling Inlet Assembly (ACI-2-2828-KIT) Parts List
Ref # Part # Description Qty
130-1245 28" Ceiling Inlet Frame 1
230-1269 Ceiling Inlet R.H. End Cap Assembly 2
330-1270 Ceiling Inlet L.H. End Cap Assembly 2
430-1242 Ceiling Inlet Side Foam 2
530-1243 Ceiling Inlet End Foam 2
6S-10819 Screw, SMSA #10 x 1-1/2" EHH SS 8
7S-10821 Screw, SMSA #8 x 3/4" FHP SS 2
8S-10822 Screw, SMSA #8 x 5/8" RHP SS 4
930-1369 Kit, Service Parts ACI-2-X Inlets 1
10 30-1235 Ceiling Inlet Static Pulley 2
11 30-1277 Ceiling Inlet Middle Pulley 1
12 30-1238 Ceiling Inlet Lock Pin 2
13 30-1204 Pin Cap Bracket 2
14 30-1202 Ceiling Inlet Latch 4
15 S-10820 Screw, TFS #10 x 1/2" RHP SS 2
16 S-10823 Screw, SMSA #8 x 1" FHP SS 16
17 30-1337 Grommet, Slot 1.2" x 0.20" 2
18 30-1370 Door, Assembly ACI-2-2828 1
19 30-1246 Ceiling Inlet Door Extrusion 1
20 30-1244 Ceiling Inlet Door Foam 1
21 30-1259 Ceiling Inlet Door Foam 4
22 S-10823 Screw, SMSA #8 x 1" FHP SS 16
23 30-1273 Ceiling Inlet R.H. End Cap P3 1
24 30-1272 Ceiling Inlet R.H. End Cap P2 1
25 30-1271 Ceiling Inlet R.H. End Cap P1 1
26 30-1276 Ceiling Inlet L.H. End Cap P3 1
27 30-1275 Ceiling Inlet L.H. End Cap P2 1
28 30-1274 Ceiling Inlet L.H. End Cap P1 1
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9

Cumberland Actuated Large Ceiling Inlet Owner's manual

Type
Owner's manual

Cumberland Actuated Large Ceiling Inlet is a versatile and efficient ventilation solution for large indoor spaces, such as warehouses, factories, and agricultural buildings. Its innovative design and advanced features provide optimal airflow control, energy efficiency, and ease of installation.

The inlet's robust construction ensures durability and longevity, while the adjustable opening allows for precise airflow regulation. The included insulation stop helps prevent heat loss, contributing to energy savings.

The inlet's actuation mechanism enables remote control of the airflow, allowing for automated ventilation based on specific temperature or humidity conditions. This feature optimizes ventilation efficiency and reduces energy consumption.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI