Yale Security YRL-220-ZW-619 User manual

Type
User manual

This manual is also suitable for

1
P/N AYRL-220-INST-FUL Rev D
Set screws
x2
Hex key
x1
M4 x 25.4mm
pan head machine
screws
x2
#7 wood & #8-32
machine x 20mm
Combination screws
x4
M4 x 8mm
pan head machine
screws
x4
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE
TO THE PRODUCT AND VOID THE FACTORY WARRANTY
Yale Real Living™ Touchscreen Lever
Installation and Programming Instructions
2
P/N AYRL-220-INST-FUL Rev D
#2 Phillips Screwdriver
2-3/8" through bolt posts
2-3/4" through bolt posts
Note: Adjustment based on backset
O
optional
default
Preparing to Install
3
P/N AYRL-220-INST-FUL Rev D
?
Left Hand
Hinges Left.
Open Inward.
“LH”
Left Hand Reverse
Hinges Left.
Open Outward
“LHR”
The hand of a door is determined from the secure side of the
door. The term "secure" means the side from which you initially
unlock and enter.
Determining Lever Handing
Left Hand Options
4
P/N AYRL-220-INST-FUL Rev D
?
The hand of a door is determined from the secure side of the
door. The term "secure" means the side from which you initially
unlock and enter.
Right Hand
Hinges Right.
Open Inward.
“RH”
Right Hand Reverse
Hinges Right.
Open Outward
“RHR”
Determining Lever Handing
Right Hand Options
5
P/N AYRL-220-INST-FUL Rev D
x4
1
Installing Latch & Strike Plate
Left Hand Installation Shown
Outside of Door
Outside of Door
Frame
Frame
6
P/N AYRL-220-INST-FUL Rev D
2
Inside of
Left Hand Door
Outside of
Left Hand Door
!
Do not remove clip
until Step 6
!
Installing Exterior Escutcheon
Left Hand Installation Shown
7
P/N AYRL-220-INST-FUL Rev D
x2
3
Inside of
Left Hand Door
Outside of
Left Hand Door
Inside of
Left Hand Door
Loosen screw to
remove cover.
Installing Interior Mounting Plate
Left Hand Installation Shown
4
Inside of
Left Hand Door
Inside of
Left Hand Door
Attaching the Cable Assembly
Left Hand Installation Shown
8
P/N AYRL-220-INST-FUL Rev D
9
P/N AYRL-220-INST-FUL Rev D
x4
5
Inside of
Left Hand Door
Installing Interior Escutcheon
Left Hand Installation Shown
10
P/N AYRL-220-INST-FUL Rev D
x1
6
Installing Exterior Lever
Remove clip.
Do not rotate internal cam
(marked red). Red mark must
remain on top and in position.
Outside of
Left Hand Door
Outside of
Left Hand Door
Do Not
Overtighten
Do Not Turn
Counter
Clockwise
!
!
!
!
!
Do Not
Overtighten
Do Not Turn
Counter
Clockwise
Outside of
Right Hand Door
11
P/N AYRL-220-INST-FUL Rev D
6
Installing Exterior Lever con't
Outside of
Left Hand Door
Outside of
Right Hand Door
12
P/N AYRL-220-INST-FUL Rev D
6
Installing Exterior Lever con't
Outside of
Left hand Door
Outside of
Left Hand Door
Do Not
Overtighten
!
!
Outside of
Right Hand Door
Do Not
Overtighten
Outside of
Right Hand Door
13
P/N AYRL-220-INST-FUL Rev D
7
6
7
6
Testing Operation
Inside of Door
Outside of
Left Hand
Door
Outside of
Right Hand
Door
Outside of
Left Hand
Door
Outside of
Right Hand
Door
Left Hand Door Shown
Right Hand Door Shown
OR
OR
14
P/N AYRL-220-INST-FUL Rev D
7
Inside of
Left Hand Door
Inside of
Right Hand Door
Do Not
Overtighten
!
Do Not
Overtighten
!
Inside of
Left Hand Door
Inside of
Right Hand Door
Almost done! Turn sheet over to finish installation and
customize your product with Programming Instructions.
Installing Interior Lever
x1
15
P/N AYRL-220-INST-FUL Rev D
7
Installing Interior Lever con't
Inside of
Left Hand Door
Inside of
Right Hand Door
Do Not Overtighten
!
Do Not Overtighten
!
16
P/N AYRL-220-INST-FUL Rev D
?
Inside of Door
7
Testing Final Operation
Outside of
Left Hand Door
17
P/N AYRL-220-INST-FUL Rev D
?
Testing Final Operation
Inside of
Left Hand Door
7
Inside of Door
Inside of Door
18
P/N AYRL-220-INST-FUL Rev D
Inside of Door
7
?
Testing Final Operation
Outside of
Left Hand Door
19
P/N AYRL-220-INST-FUL Rev D
Installing Optional Radio Module
8
Inside of
Left Hand Door
Installing Batteries & Cover
9
Congratulations, you've installed the Yale Real Living™ Touchscreen Lever!
Continue with Programming Instructions to customize your product.
Inside of
Left Hand Door
"Welcome to
Yale Real Living."
Tighten screw
to replace cover.
20
P/N AYRL-220-INST-FUL Rev D
Resetting Lock to Factory Default
Reset Button
Interior Escutcheon
FCC:
Class B Equipment
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada:
This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations.
Cet appareillage numérique de la classe A répond à toutes les exigences de l'interférence canadienne causant des règlements
d'équipement.
Warning: Changes or modifications to this device, not expressly approved by Yale Security Inc. could void the user's authority to
operate the equipment.
When lock is reset to factory defaults all user codes
(including the Master PIN code*) are deleted and all
programming features are reset to original default
settings (see below).
1. Remove the battery cover and batteries.
2. Remove the interior escutcheon to access the
reset button.
3. The reset button (see image at right) is located
above the PCB cable connector.
4. While pressing the reset button (minimum of 3
seconds) reinstall batteries. Release reset button.
5. Replace battery cover.
Upon reset, Master PIN Code creation is the only
option available and must be performed prior to any
other programming of the lock.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Yale Security YRL-220-ZW-619 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document