Abloy ML81APV Operating instructions

Type
Operating instructions
ML81APV, ML81APH INSTRUCTIONS
An ASSA ABLOY Group brand
CHANGING THE MASTER-CODE
1. Press for 4 seconds (green LED starts to blink)
2. Enter Master-code (factory setting 1111) and press
3. Enter new Master-code (4 - 12 numbers) and press
4. Enter new Master-code again and press
Short melody and LED blinks several times when changed successfully.
Note. The master-code of the lock must be changed before taking the lock into use due safety reasons.
Note. Changing Master-code will delete User-code.
ADDING USER-CODE
1. Press for 4 seconds (green LED starts to blink)
2. Enter Master-code and press
3. Enter new User-code (4 - 12 numbers) and press
Short melody and LED blinks several times when changed successfully.
Note. Opening with the Master-code will delete the User-code.
CHANGING THE USER-CODE
1. Press for 4 seconds (green LED starts to blink)
2. Enter User-code and press
3. Enter new User-code (4 - 12 numbers) and press
Short melody and LED blinks several times when changed successfully.
OPENING WITH THE MASTER-CODE
+ Master-code +
OPENING WITH THE USER-CODE
User-code +
OUT OF BATTERY
There will be battery warning alarms, 5 beeps, while opening
and closing the lock. Do not use the lock before the batteries
have been replaced. Use 3x 1,5V AA alkaline batteries only.
Batteries last for 2 years or 6000 cycles.
When the lock makes battery warning alarm a standard DC 5V
charger with Micro USB cable can be used to supply the power.
MELODY OFF
and pressed
simultaneously for 2 seconds
MELODY ON
and pressed
simultaneously for 2 seconds
RESET (if there is unknown problem and lock does not work. Does not delete codes)
Press and simultaneously (Short melody and green and red LED blinks)
Note. The door
must be closed
or the latch
pressed down.
Note. The door
must be closed
or the latch
pressed down.
Note. The door
must be closed
or the latch
pressed down.
USB-connector
18.12.2017 Rev.0
RESET TO FACTORY SETTINGS
An ASSA ABLOY Group brand
1. Couple the “Reset” points with sharp tweezers or similar.
2. Press the latch.
3. Remove “Reset” coupling.
Short melody and LED blinks several times after reset.
Master-code resets to 1111.
EMERGENCY OPENING
Use emergency opening if the lock does not work at all (breaks the lock).
1. Drill a hole through the key pad as shown in the pictures.
2. Insert a screwdriver into the hole and turn clockwise and the lock will open.
PROBLEM SITUATIONS
ø3 - ø6
22
ø6,5
ML81APV ML81APH
CARE INSTRUCTIONS
Use a damp, soft cloth for removing stains and ngerprints from the lock. For grease and other accumulated dirt
use cloth with mild cleaning agent. The lock does not need to be greased.