Hoshizaki American, Inc. F-500BAF User manual

Type
User manual

This manual is also suitable for

Hoshizaki American, Inc. F-500BAF-C is a self-contained flaker ice maker designed to produce up to 431 lbs. of flaked ice per day. It features an auger-type harvesting system, a direct-driven auger with a 1/6 HP gear motor, and a mechanical bin control system with a proximity switch. The ice maker has a durable exterior finish of PVC-coated galvanized steel, galvanized steel at the rear, and stainless steel at the top. It requires a 115V/60Hz/1-phase power supply and has a maximum fuse size of 20A.

Hoshizaki American, Inc. F-500BAF-C is a self-contained flaker ice maker designed to produce up to 431 lbs. of flaked ice per day. It features an auger-type harvesting system, a direct-driven auger with a 1/6 HP gear motor, and a mechanical bin control system with a proximity switch. The ice maker has a durable exterior finish of PVC-coated galvanized steel, galvanized steel at the rear, and stainless steel at the top. It requires a 115V/60Hz/1-phase power supply and has a maximum fuse size of 20A.

SERVICE MANUAL
NO:
73074
F-500BAF/-C
HOSHIZAKI
SELF-CONTAINED FLAKER
MODEL
ISSUED:
MAR. 2, 1999
REVISED:
DEC. 26, 2003
2
HOSHIZAKI AMERICA, INC.
618 Highway 74 South
Peachtree City, GA 30269
Attn: HOSHIZAKI Technical Support Department
Phone: 1-800-233-1940 Technical Service
(770) 487-2331
Fax: (770) 487-3360
NOTE: To expedite assistance, all correspondence/communication MUST include the following
information:
• Model Number
• Serial Number
Complete and detailed explanation of the problem
IMPORTANT
Only qualified service technicians should attempt to service or maintain this icemaker.
No service or maintenance should be undertaken until the technician has
thoroughly read this Service Manual.
HOSHIZAKI provides this manual primarily to assist qualified service technicians in the
service and maintenance of the icemaker.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call or write to the HOSHIZAKI Technical Support Department for
assistance.
3
Please review this manual. It should be read carefully before the icemaker is serviced or
maintenance operations are performed. Only qualified service technicians should service
and maintain the icemaker. This manual should be made available to the technician prior
to service or maintenance.
CONTENTS
PAGE
I. SPECIFICATIONS .................................................................................................... 5
F-500BAF............................................................................................................... 5
F-500BAF-C ........................................................................................................... 6
II. GENERAL INFORMATION ...................................................................................... 7
1. CONSTRUCTION................................................................................................... 7
F-500BAF, F-500BAF-C......................................................................................... 7
2. ICE MAKING UNIT ................................................................................................. 8
3. CONTROL BOX LAYOUT ...................................................................................... 9
F-500BAF, F-500BAF-C......................................................................................... 9
4. TIMER BOARD..................................................................................................... 10
[a] SOLID-STATE CONTROL .............................................................................. 10
[b] TIMER BOARD ............................................................................................... 10
[c] SEQUENCE .................................................................................................... 11
III. TECHNICAL INFORMATION................................................................................ 14
1. WATER CIRCUIT AND REFRIGERANT CIRCUIT .............................................. 14
F-500BAF, F-500BAF-C....................................................................................... 14
2. WIRING DIAGRAM .............................................................................................. 15
F-500BAF, F-500BAF-C....................................................................................... 15
3. SEQUENCE OF ELECTRICAL CIRCUIT............................................................. 16
F-500BAF, F-500BAF-C....................................................................................... 16
4. TIMING CHART.................................................................................................... 21
5. PERFORMANCE DATA ....................................................................................... 24
F-500BAF............................................................................................................. 24
F-500BAF-C ......................................................................................................... 25
IV. SERVICE DIAGNOSIS ......................................................................................... 26
1. NO ICE PRODUCTION ........................................................................................ 26
2. LOW ICE PRODUCTION ..................................................................................... 29
3. OTHERS............................................................................................................... 30
V. REMOVAL AND REPLACEMENT OF COMPONENTS ........................................ 31
1. SERVICE FOR REFRIGERANT LINES ............................................................... 31
[a] REFRIGERANT RECOVERY ......................................................................... 31
[b] EVACUATION AND RECHARGE ................................................................... 31
2. BRAZING.............................................................................................................. 32
3. REMOVAL AND REPLACEMENT OF COMPRESSOR....................................... 33
4
4. REMOVAL AND REPLACEMENT OF DRIER ..................................................... 34
5. REMOVAL AND REPLACEMENT OF EXPANSION VALVE............................... 35
6. REMOVAL AND REPLACEMENT OF EVAPORATOR ASSEMBLY ................... 36
7. REMOVAL AND REPLACEMENT OF FAN MOTOR ........................................... 40
8. REMOVAL AND REPLACEMENT OF CONTROL WATER VALVE .................... 40
VI. MAINTENANCE AND CLEANING INSTRUCTIONS............................................ 41
1. PREPARING THE ICEMAKER FOR LONG STORAGE ...................................... 41
2. CLEANING INSTRUCTIONS ............................................................................... 42
3. MAINTENANCE ................................................................................................... 46
5
I. SPECIFICATIONS
F-500BAF
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 7.9 RLA 51 LRA
GEAR MOTOR 120 V 1.6 FLA 1/6 HP
FAN MOTOR 120 V 0.85 FLA 1/15 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F)507090
lbs./day ( kg/day ) 70 * 478 (217) 458 (208) 438 (199)
Reference without *marks 80 419 (190) 400 (182) 383 (174)
90 366 (166) * 359 (163) 335 (152)
100 320 (145) 306 (139) * 287 (130)
SHAPE OF ICE Flake
ICE QUALITY Approx. 70%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY 250 lbs.
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 900 (6.0) 854 (4.3)
POTABLE WATER 43 (12) 57 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 38" x 29" x 36" (965 x 735 x 915 mm)
EXTERIOR FINISH PVC Coated Galvanized Steel; Galvanized Steel (Rear);
Stainless Steel (Top)
WEIGHT Net 210 lbs. ( 95 kg ), Shipping 245 lbs. ( 111 kg )
CONNECTIONS - ELECTRIC Permanent Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Drain Pan 3/4" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43C1E-CAA
CONDENSER Air-cooled, Fin and tube type
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. (470 g)
DESIGN PRESSURE High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop, Spare Fuse
- REQUIRED Legs
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
DRAWING NO. (DIMENSIONS) 339850---
We reserve the right to make changes in specifications and design without prior notice.
6
F-500BAF-C
AC SUPPLY VOLTAGE 115/60/1
COMPRESSOR 120 V 7.9 RLA 51 LRA
GEAR MOTOR 120 V 1.6 FLA 1/6 HP
FAN MOTOR 120 V 0.85 FLA 1/15 HP
OTHER 120 V 0.03 A
MAXIMUM FUSE SIZE 20 A
MAX. HACR BREAKER (USA ONLY) 20 A
MAX. CIRC. BREAKER (CANADA ONLY) 20 A
MINIMUM CIRCUIT AMPACITY 20 A
APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F)
PER 24 HR. Temp.(°F) 50 70 90
lbs./day ( kg/day ) 70 * 431 (196) 415 (188) 398 (181)
Reference without *marks 80 381 (173) 365 (166) 350 (159)
90 336 (152) * 333 (151) 308 (140)
100 295 (134) 283 (128) * 263 (119)
SHAPE OF ICE Cubelet
ICE QUALITY Approx. 80%, Ice (90/70°F, Conductivity 200 µs/cm)
APPROXIMATE STORAGE CAPACITY 250 lbs.
ELECTRIC & WATER CONSUMPTION 90/70°F 70/50°F
ELECTRIC W (kWH/100 lbs.) 903 (6.5) 864 (4.8)
POTABLE WATER 40 (12) 52 (12)
gal./24HR (gal./100 lbs.)
EXTERIOR DIMENSIONS (WxDxH) 38" x 29" x 36" (965 x 735 x 915 mm)
EXTERIOR FINISH PVC Coated Galvanized Steel; Galvanized Steel (Rear);
Stainless Steel (Top)
WEIGHT Net 210 lbs. ( 95 kg ), Shipping 245 lbs. ( 111 kg )
CONNECTIONS - ELECTRIC Permanent Connection
- WATER SUPPLY Inlet 1/2" FPT
- DRAIN Drain Pan 3/4" FPT
Bin Drain 3/4" FPT
ICE MAKING SYSTEM Auger type
HARVESTING SYSTEM Direct Driven Auger ( 1/6 HP Gear Motor )
ICE MAKING WATER CONTROL Float Switch
COOLING WATER CONTROL N/A
BIN CONTROL SYSTEM Mechanical Bin Control ( Proximity Sw. )
COMPRESSOR Hermetic, Model RS43C1E-CAA
CONDENSER Air-cooled, Fin and tube type
EVAPORATOR Copper Tube on Cylinder
REFRIGERANT CONTROL Thermostatic Expansion Valve
REFRIGERANT CHARGE R-404A, 1 lb. (470 g)
DESIGN PRESSURE High 460 PSIG, Low 290 PSIG
P.C. BOARD CIRCUIT PROTECTION High Voltage Cut-off Relay
COMPRESSOR PROTECTION Auto-reset Overload Protector
GEAR MOTOR PROTECTION Manual reset Circuit Breaker
REFRIGERANT CIRCUIT PROTECTION Auto-reset High Pressure Control Switch
LOW WATER PROTECTION Float Switch and Timer
ACCESSORIES - SUPPLIED Ice Scoop, Spare Fuse
- REQUIRED Legs
OPERATING CONDITIONS VOLTAGE RANGE 104 - 127 V
AMBIENT TEMP. 45 - 100° F
WATER SUPPLY TEMP. 45 - 90° F
WATER SUPPLY PRESSURE 10 - 113 PSIG
DRAWING NO. (DIMENSIONS) 339850---
We reserve the right to make changes in specifications and design without prior notice.
7
II. GENERAL INFORMATION
1. CONSTRUCTION
F-500BAF, F-500BAF-C
Top Panel
Side Panel
Sliding Door
Water Supply Inlet
Control Water Valve
Reservoir
Evaporator
Condenser
Condenser Fan
Spout
Gear Motor
Access Valve
Compressor
Control Box
Side Panel
Front Panel
8
2. ICE MAKING UNIT
9
CONTROL
TIMER
CONNECTOR
PRESSURE
SWITCH
TRANSFORMER
WATER CONTROL
RELAY
FLUSH
FLUSH SWITCH
ICE
FUSE
CIRCUIT
BREAKER
OFF
ON
POWER SWITCH
CIRCUIT PROTECT
RELAY
GEAR MOTOR
PROTECT RELAY
CAPACITOR FOR
GEAR MOTOR
CAPACITOR FOR
FAN MOTOR
START
CAPACITOR
RUN
CAPACITOR
STARTER
FLUSH VALVE
CONTROL RELAY
Note: The above component names are identical with the Wiring Label, but not with the Parts
List.
3. CONTROL BOX LAYOUT
F-500BAF, F-500BAF-C
10
4. TIMER BOARD
[a] SOLID-STATE CONTROL
1) A HOSHIZAKI exclusive solid-state control is employed in the self-contained flaker
icemakers.
2) A Printed Circuit Board (hereafter called “Timer Board”) includes a stable and high qual-
ity control system.
3) All models are pre-tested and factory adjusted.
[b] TIMER BOARD
CAUTION
1. Fragile, handle very carefully.
2. A timer board contains CMOS (Complementary Metal-Oxide Semiconduc-
tor) integrated circuits, which are susceptible to failure due to static dis-
charge. It is especially important to use an anti-static wrist strap when
handling or replacing the board.
3. Do not touch the electronic devices on the board or the back of the board to
prevent damage to the board.
4. Do not change wiring and connections. Especially, never misconnect
terminals.
5. Do not fix the electronic devices or parts on the board in the field. Always
replace the whole board assembly when it goes bad.
The icemaker is controlled by the Timer Board for the following purposes:
1) To prevent the Gear Motor and the Compressor from starting or stopping simulta-
neously.
2) To reduce remaining ice in the refrigeration casing.
3) To protect the unit in case of low water and low water pressure.
4) To protect the unit in case the Bin Control causes chattering.
11
Fig. 1
[C] SEQUENCE
Fig. 2
12
Fig. 3
EDOCTRAP10-503734
LEDOM10C441AA2H
GNITARzH06/05CAV42
1T.ces51±06
2T.ces22±09
3T.ces54±051
4Tsselro.ces1
5T%07±.ces7.6
6T%07±.ces7.6
13
Functions of Terminals
1) Terminals 1, 2
Power supply AC 24V.
2) Terminals 3, 4
Control X1 (GM) and X2 (CM) Relays.
When closed, energize X1 (GM) in 1 sec. and X2 (CM) in 60 sec.
When opened, de-energize X1 (GM) in 150 sec. and X2 (CM) in 90 sec.
3) Terminals 5, 6
Control X1 (GM) and X2 (CM) Relays.
When opened, de-energize X1 (GM) and X2 (CM) immediately.
When closed again, energize X1 (GM) in 1 sec. and X2 (CM) in 60 sec.
4) Terminals 7, 8, 9
X1 (GM) contacts.
8 is a movable contact, 7 is a make contact, and 9 is a break contact.
5) Terminals 10, 11
Control X2 (CM) Relays.
When opened, de-energize X2 (CM) immediately.
When closed, energize X2 (CM) immediately.
Note: 1. X2 Relay is a single pole, normally open relay, and its terminals are mounted
on the relay itself.
2. The above operation times are median. See Fig. 3 for details.
14
1. WATER CIRCUIT AND REFRIGERANT CIRCUIT
F-500BAF, F-500BAF-C
SPOUT
CONTROL
WATER
VALVE
FLOAT
SWITCH
RESERVOIR
OVERFLOW
GEAR
MOTOR
WATER LEVEL
EVAPORATOR
WATER
INLET
DRIER
CONDENSER
CONDENSER
FAN MOTOR
PRESSURE
SWITCH
COMPRESSOR
WATER CIRCUIT
REFRIGERANT CIRCUIT
ACCESS
VALVE
DRAIN
OUTLET
DRAIN PAN
DRAIN PAN
FLUSH
WATER
VALVE
ACCESS
VALVE
EXPANSION
VALVE
15
2. WIRING DIAGRAM
F-500BAF, F-500BAF-C
16
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
3. SEQUENCE OF ELECTRICAL CIRCUIT
F-500BAF/-C
[a] When Power Switch is moved to "ON" position and Flush Switch to "ICE"
position, water starts to be supplied to Reservoir.
17
[b] When Reservoir has been filled up, Gear Motor starts immediately.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
18
[c] Compressor starts about 60 sec. after Gear Motor starts.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
19
[d] Compressor stops about 90 sec. after Bin Control operates. Gear Motor stops about
60 sec. later, and water is drained from the water circuit. Water can be also drained
by moving Flush Switch to "FLUSH" position.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
20
[e] When 208 - 230V are supplied to the power supply due to miswiring, Circuit Protect
Relay operates, and the icemaker does not run.
MOT.
PROTECTOR
115-120/60/1
L
N
8
7
5
3
1
CIRCUIT
PROTECT
RELAY (X5)
CONTROL
SWITCH
K
1
C
BR
W
START CAP.
270-324MFD
1
5
2
COMP.
31
R
BK
C
R
S
V
1
3
5
7
2
4
6
8
GEAR MOTOR
PROTECT RELAY
(X4)
K
5
A
K
6
A
GEAR
MOTOR
CAP.
10MFD
K
8
A
K
6
C
K
3
C
K
4
C
K
3
A
K
1
A
K
9
A
K
7
A
V
THERMAL
PROTECTOR
CIRCUIT
SWITCH
GY
BK
(O)
(Y)
(DBU)
CAP.
2.5MFD
(BR)
P
LBU
(BR)
(BK)
K
6
B
K
4
A
CONDENSER FAN MOTOR
K
2
A
(W)
DBU
PRESSURE
SWITCH
8
123
45
610
11
7
4
3
O
9
W
BR
R
O
GY
P
VBK
R
LBU
CONTROL
TIMER
TRANS.
O
(O)
CONTROL
WATER VALVE
BR
DBU
O
BK
(BU)
(BK)
FLOAT SWITCH
1
3
2
4
6
8
5
7
K
1
D
K
4
B
K
3
B
K
5
B
WATER CONTROL RELAY
(X3)
K
2
D
BK
24V
(BK)
FLUSH WATER
VALVE
FUSE (1A)
R
K
2
B
LBU
5
4
3
2
1
K
1
B
FLUSH RELAY (X6)
K
3
D
K
4
D
BIN CONTROL SWITCH
P
FLUSH
SWITCH
LBU
(O)
RUN CAP.
15MFD
O
DBU
STARTER
R
P
O
O
BR
W
BK
R
O
GY
P
DBU
V
Y
LBU
BU
BROWN
WHITE
BLACK
RED
ORANGE
GRAY
PINK
DARK BLUE
VIOLET
YELLOW
LIGHT BLUE
BLUE
WIRE COLOR CODE
(F-500BAF(-C))
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47

Hoshizaki American, Inc. F-500BAF User manual

Type
User manual
This manual is also suitable for

Hoshizaki American, Inc. F-500BAF-C is a self-contained flaker ice maker designed to produce up to 431 lbs. of flaked ice per day. It features an auger-type harvesting system, a direct-driven auger with a 1/6 HP gear motor, and a mechanical bin control system with a proximity switch. The ice maker has a durable exterior finish of PVC-coated galvanized steel, galvanized steel at the rear, and stainless steel at the top. It requires a 115V/60Hz/1-phase power supply and has a maximum fuse size of 20A.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI