www.esabna.com
DATE: July 22, 2004 BULLETIN NO: M_04_012
TITLE/ PRODUCT NAME: Aristo Communications Error Codes
RATING:
_
_ DIRECTIVE _X_ ALERT
(Action is Required) (Potential Problem)
_
X_ INFORMATION _ _ PRODUCT IMPROVEMENT
(Action is Optional) (Enhanced Product)
_
X_ General Distribution _ _ Business Confidential
(Unrestricted) (Restricted Distribution)
PRODUCT SERIES/ MODEL:
All Aristo Models
SERIAL NO:
All
SUMMARY:
If communications Error Codes #12, 14, 15,17,18 or 19 is displayed or the control panel
experiences a “lock-up” where manipulation of the buttons or knobs has no effect, check to
see if the terminating resistor is installed or damaged.
The Aristo Products use a serial communications protocol (CAN bus) to communicated
between system components. The ends of the CAN bus must be fitted with a “terminating
Resistor” to avoid communications interference. One end of the CAN bus is at the control
panel (MA-4, Ma-6, etc.) which has an internal terminating resistor. The other end, at the
power source, must be fitted with a terminating resistor as shown below.
OPERATIONAL IMPACT:
More stable communications between Power source, wire feeder and other components