  • Hello! I am an AI chatbot trained to assist you with the Mircom LT-1019 QAA-5160 70V Amplifier Operating instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
LT-1019 Rev. 2
April 2014
QAA-5160-70/25
Single 60 Watt Amplifier
Voltage Selection and Backup Instructions
Molex Cable Location
The QAA-5160 Amplifier may operate as a 70V or 25V amplifier. THE DEFAULT VOLTAGE IS 70V. To change the
amplifier to 25V, remove the orange molex cable (labelled MD-790) between J8 and J9 and replace it with the blue molex
cable (labelled MD-791) provided with the amplifier, connecting J8 and J9. Refer to Figure 1 below for molex cable
location.
Figure 1: 70V/25V Molex Cable Location
MOTHERBOARD
CONNECTOR
CAPACITORS
XMFR
HEAT SINKHEAT SINK
XMFR
SPEAKER
TERMINALS
RELAYS
J9 J8
FOR AMPLIFIER TO OPERATE AS 25V, REMOVE ORANGE CABLE LABELLED MD-790
FROM J9 AND J8 AND REPLACE WITH BLUE CABLE MARKED MD- 791 BETWEEN J9
AND J8.
QAA-5160-70/25 AMPLIFIER
LT-1019 Rev. 2
April 2014
Backup Amplifier
The QAA-5160 Amplifier may be used as a backup amplifier. One backup is required per system or node.
To use this amplifier as a backup, the molex connector MD-789 packaged with the amplifier, must be
placed over the pins of J10 as shown in figure below.
CAPACITORS
XMFR
HEAT SINKHEAT SINK
XMFR
RELAYS
J9 J8
81
J10
QAA-5160-70/25 AMPLIFIER
MOTHERBOARD
CONNECTOR
Mount the
molex plug
MD-789 over
the 4 pins at
J10 if using
this amplifer
as a backup.
SPEAKER TERMINALS
/