AKR 951 IX WP

Whirlpool AKR 951 IX WP Program Chart

  • Hello! I am an AI chatbot trained to assist you with the Whirlpool AKR 951 IX WP Program Chart. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
5019 318
33095
AKR 951 - AKR 960
INSTALLATIONSBLAD
Minsta tillåtna avstånd från olika typer av spisar: 50 cm (elektrisk spis), 75 cm
(gasspis, gasolspis och koleldad spis). Följ givna anvisningar och
nummerordningen (1
Ö
2
Ö
3
Ö
.....) när fläktkåpan skall monteras. Slå inte på
strömmen till fläktkåpan förrän installationen är helt avslutad.
Rökröret och rörklämmorna som krävs för installationen levereras inte
tillsammans med fläktkåpan, utan måste köpas separat.
INSTALLASJONSVEILEDNING
Minimumsavstand til komfyrtopp: 50 cm (elektriske kokeplater), 75 cm (gass-,
parafin- eller kullkomfyr). Følg nummereringen ved montering (1
Ö
2
Ö
3
Ö
.....),
samt monteringsanvisningene. Apparatet må ikke tilkobles strømnettet før
installasjonen er helt avsluttet.
Merk! Avtrekksrøret og klemmene følger ikke med og må bestilles separat.
INSTALLATIONSVEJLEDNING
Minimumafstand fra kogezoner: 50 cm (elkogezoner), 75 cm (gas-, olie- eller
kulfyrede kogezoner). Ved montering skal man følge vejledningens
nummerrækkefølge (1
Ö
2
Ö
3
Ö
.....) og de tilhørende instruktioner. Apparatet
ikke tilsluttes elforsyningen, før installationen er fuldført.
Advarsel! Aftræksrøret og spændebåndene leveres ikke med emhætten og skal
købes separat.
ASENNUSOHJEET
Vähimmäisetäisyys liedestä: 50 cm (sähkölevyt), 75 cm (kaasu-, öljy- tai
hiililiedet). Suorita asennus numerojärjestyksessä (1
Ö
2
Ö
3
Ö
.....) ohjeiden
mukaisesti. Älä kytke laitetta sähköverkkoon ennen kuin kokoonpano on
kokonaan suoritettu.
Huomaa! Poistoputkea ja kiinnittimiä ei toimiteta laitteen mukana, vaan ne on
hankittava erikseen.
INSTALLATION SHEET
Minimum height above cooker: 50 cm (electric cookers), 75 cm (gas, gas oil or
coal cookers). To assemble follow the numbers (1
Ö
2
Ö
3
Ö
.....) and relative
instructions. Do not connect the appliance to the electrical power supply until
installation is completed.
Warning! The exhaust pipe and clamps are not supplied and must be bought
separately.
S
N
DK
FIN
GB
31833095.fm Page 1 Thursday, November 20, 2003 5:35 PM
AKR 951 - AKR 960
5019 318
33095
3
4
4
4
4
4
4
6
6
7
7
7
7
8
8
2a
2
2a
5
7
9
10
10
10
10
11
14,5
273
273
244
214
190
6
12
2
B
11
31833095.fm Page 2 Thursday, November 20, 2003 5:35 PM
5019 318
33095
AKR 951 - AKR 960
15
15
15
15
15
16
16
15
15
13A
15
14
H
F
G
13F
31833095.fm Page 3 Thursday, November 20, 2003 5:35 PM
AKR 951 - AKR 960
5019 318
33095
18
18
18
18
18
18
18
18
18
18
M
17
19
X
X
20
20
19
31833095.fm Page 4 Thursday, November 20, 2003 5:35 PM
5019 318
33095
AKR 951 - AKR 960
Preliminary information for installing the hood:
Expansion plugs are provided to secure the hood to most types of ceilings. A qualified technician is needed,
however, to make sure that the plugs are suitable for your ceiling. The ceiling must be strong enough to take
the weight of the hood.
Disconnect the power supply at the home main switch during electrical connections.
1.
Adjust extension of the hood support structure, as the final height of the hood depends on this, and
remember that with installation completed the hood must be at least 50 cm above the cooktop in case of
electric cookers and 75 cm in case of gas or mixed cookers.
2.
Fix the two sections of the structure using 8 screws.
3.
Place the ceiling hole diagram directly above the cooktop (the centre of the diagram must match the
centre of the cooktop and the edges must be parallel to the sides of the cooktop - the side of the diagram
with the wording FRONT corresponds to the control panel side). Prepare the electrical connection.
4.
Drill as shown (6 holes for 6 wall plugs - 4 plugs for hooking), screw the 4 outer screws leaving a space
of about 1 cm between the screw head and the ceiling.
5.
Fit an exhaust pipe inside the truss and connect it to the collar of the motor compartment (exhaust pipe
and clamps are not provided).
6.
Hook the truss to the 4 screws (see step 4).
CAUTION! The side of the truss with connection box corresponds to the side of the control panel with
hood assembled.
7.
Tighten the 4 screws.
8.
Insert and tighten another 2 screws in the remaining free holes for secure fixing.
9.
Carry out the electrical connection to the mains power supply, only turn on the power supply with
assembly completed.
10.
Hook the hood to the truss, check for perfect hooking - to hook the hood to the truss partially screw 4
screws (also see step 12).
11.
Fixing the hood to the truss with two screws, will also facilitate centering the two parts.
12.
Tighten the 4 screws fixing the truss to the hood.
13.
For extractor operation (
13A
), connect the other end of the exhaust pipe to the home drain device.
For filter operation (
13F
), fit deflector
F
on the truss and fix it with 4 screws to the special bracket.
Finally, connect the exhaust pipe to the collar located on the deflector.
14.
Fit the nuts with fixing hooks supplied inside the top and bottom sections of the flues at the rectangular
slots. A total of 10 nuts must be fitted.
15.
Join the two top sections of the flue to cover the truss so that one of the slots on the sections is situated
on the same side of the control panel and the other on the opposite side.
Screw the two sections with 4 screws (2 each side - see the plan diagram for joining the two sections).
16.
Fix the top flue assembly to the truss, near the ceiling, with two screws (one each side).
17.
Carry out electrical connection of control panel and bulbs.
18.
Join the two bottom sections of the flue covering the truss using 6 screws (3 each side - also see the plan
diagram for joining the two sections).
19.
Insert the bottom section of the flue in the special seat to completely cover the motor compartment and
electrical connection box, and fix the hood with two screws from the inside.
20.
Apply the 2 tabs (supplied) to cover the fixing points of the bottom flue (CAUTION! THE BOTTOM FLUE
TABS ARE THE NARROWER AND SHALLOWER ONES).
The wider and deeper tabs are those used for the top flue, and must be cut to size.
21.
Turn the mains power on again at the central electrical panel and check for correct hood operation.
INSTALLATION - ASSEMBLY INSTRUCTIONS
S N DK
FIN GB
31833095.fm Page 13 Thursday, November 20, 2003 5:35 PM
AKR 951 - AKR 960
5019 318
33095
1.
Control panel.
2.
Grease filter.
3.
Halogen bulbs.
4.
Steam deflector.
5.
Telescopic flue.
To clean the grease filter
Wash the grease filter at least once a month.
1.
Disconnect the electrical power supply.
2.
Remove the grease filters -
Fig. 1
: pull the spring
release handle
(f)
downwards, then remove the
filter.
3.
After cleaning the grease filter refit in reverse
order, making sure the entire extraction surface
is covered.
Carbon filter Fitting and Maintenance
Fitting the carbon filter:
1.
Disconnect the electrical power supply.
2.
Remove the grease filter
(f - Fig. 1)
.
3.
Turn the side knobs 90° and then remove the
filter holder
(g - Fig. 2)
.
4.
Fit the carbon filter
(h - Fig. 2)
in the filter
holder
(i - Fig. 2)
.
5.
Refit the filter holder and secure it to the hood
with the screw
(g - Fig. 2)
.
6.
Refit the grease filter.
Carbon filter maintenance:
Unlike traditional carbon filters, this carbon filter can
be washed and reactivated.
With normal hood use, the filter should be cleaned
once a month. The best way to clean the filter is in a
dishwasher at the highest temperature possible,
using a normal dishwasher detergent. To avoid
particles of food or dirt settling on the filter during
washing and giving rise to unpleasant smells, it is
advisable to wash the filter on its own. After
washing, dry the filter in the oven at 100° C for 10
minutes to reactivate it.
The filter will retain its odour-absorbing capacity for
three years, after which it must be replaced.
Replacing bulbs
1.
Disconnect the electrical power supply.
2.
Use a small screwdriver or any other suitable tool
to prise off
(m-Fig. 3)
the lamp cover
(p-Fig. 3)
.
3.
Remove the burnt-out bulb.
Replace using 20 W max halogen bulbs only,
making sure not to touch them with your hands.
4.
Close the lighting unit (snap-close).
CONTROL PANEL
A.
Light ON/OFF switch.
B.
ON/OFF and speed 1 selector switch
(small amount of steam and fumes).
B+C.
Speed 2 selector switch
(medium amount of steam and fumes).
B+D.
Speed 3 selector switch
(large amount of steam and fumes).
ABCD
2
1
5
4
f1
f2
3
Fig. 1
Fig. 4
Fig. 2
Fig. 3
PRODUCT SHEET