Genie 2020L User manual

Category
Garage Door Opener
Type
User manual

This manual is also suitable for

Operation and Maintenance Manual
3681036666
GARAGE
TABLE OF CONTENTS
Warranty Information ................... 2
Safety Information ..................... 3
Safety Features ......................... 3
Important Installation Instructions ....... 3
Pre-lnstallation Checklist .............. 4-6
Adjustments .......................... 7-8
Programming the Remote Control ...... 8
Installing lightbulb and lens ............. 9
Scheduled Maintenance ............... 10
Troubleshooting Guide ............. 10-11
Wiring Diagram ........................ 12
Parts Lists and Exploded Views ..... 12 -13
Accessories ............................ 14
COMPLETE WiTH INTELLICODE ®
REMOTE CONTROL AND SERIESII
ELECTRONICS
For 7' 6" Doors. Extension Kit is available for 8' Doors
Included Wall Control MUST be installed prior to Operation
of this Garage Door Operator.
Safe-T-Beam ®Safety Reverse System Must be installed and
the Force Controls MUST be Properly Set to close door.
This Equipment meets or exceeds all Federal, State and UL 325
Safety Requirements.
Having Difficulty? Need Help?
Please call us:1-800-35-GENIE (354-3643)
www.geniecompany.com
Please have Model information ready when calling.
THE GENIE COMPANY LiMiTED WARRANTY
What is covered?
Any defect in material and product workmanship from personal, normal
household usein accordance with the Owner's Manual.
For how long?
MODEL2020LSeries... 10yearson motor and 2 yearson all other parts.
Who gets the warranty?
This warranty islimited to the consumer who originally purchased
the product.
Geographic scope:
This warranty applies only to units installed and operated within the country
where they were purchased.
Limitations:
IMPLIEDWARRANTIES,INCLUDINGTHOSEOFFITNESSFORA PARTICULAR
PURPOSEANDMERCHANTABILITY(AN UNWRITTENWARRANTYTHATTHE
PRODUCTISFITFORORDINARYUSE),ARELIMITEDTO ONEYEARFROMTHE
DATEOFPURCHASE.GENIEWILL NOTPAYFOR:LOSSOFTIME;
INCONVENIENCE;LOSSOFUSEOF YOURGENIEPRODUCTORPROPERTY
DAMAGECAUSEDBYYOURGENIEPRODUCTORITSFAILURETOWORK;ANY
SPECIAL,INCIDENTALORCONSEQUENTIALDAMAGES;ORANYDAMAGES
RESULTINGFROMMISUSEORMODIFICATIONOFYOURGENIEPRODUCT.
Some statesand provinces do not allow limitations on how long animplied
warranty lasts or the exclusion of incidental or consequential damages,so the
above limitations or exclusionsmay not apply to you.
This warranty isthe only one we will giveon your Genieproduct, and it sets
forth all our responsibilities regarding your Genieproduct.There are noother
express warranties.
State and province rights: This warranty gives you specific legalrights, and
you may also haveother rights which vary from state to state andprovince to
province.
How to get warranty service:
To obtain warranty servicefor your Genie product, you must provide proof of
the date and place of purchaseof the product.
1.Do=it-Yourself-Service.
Callthe Genie Customer Servicetoll free at 1.800.354.3643to speakin
person to a trained Genierepresentative for assistancein diagnosing the
problem and arranging to supply you with the required parts for do-it-
yourself repairs.Trained service representativesare available Monday-Friday,
8:00a.m.- 9:00 p.m., EasternTime,and on Saturday, 10:00a.m.to 7:00p.m.,
EasternTime (subject to holidays) You may alsoget the information you
needat www.geniecompany.com.
2.Service From Authorized Dealers.
YoualsomayobtainwarrantyservicefromGenieauthorizeddealersbycallingthe
GenieCustomerServiceat 1.800.354.3643or byvisitingwww.geniecompony.com
beforeschedulingwarrantyservice.Ifwarrantyserviceisprovidedbyanauthorized
dealer,Geniewill provideallrequiredpartsunderwarrantyatnochargeto you,but
thedealersareindependentbusinesspeopleandmayrenderabenchor servicecall
chargefortheirservices.Geniewill notreimburseyouorotherwiseberesponsiblefor
thosecharges.
Wesuggestthatyouretainyouroriginalpackingmaterialin theeventwechoose
to repairor replaceyourGenieProductandrequestthat youshipit to us.Besureto
includeyourname,address,telephonenumber,proofofdateandplaceofpurchase
andadescriptionoftheoperatingproblem.Afterrepairingorreplacing,yourGenie
product,wewillshipit toyourhomeatnocosttoyoufor partsandlabor,butyouwill
haveto payaminimumof$S.00forshippingandhandlingcharges.
Yourchoiceof eitheroneofthe above-describedserviceoptionsisyour exclusive
remedyunderthiswarranty.
What this warranty does not cover:
Thiswarrantydoesnotcoverbatteries(whichareconsideredreplaceableparts),
installation,commercialuse,defectsresultingfromaccidents,damagewhileintransit
to ourservicelocationordamageresultingfromalterations,misuseorabuse,lackof
propermaintenance,unauthorizedrepairor modificationoftheproduct,affixingof
anyattachmentnot providedwith the product, programmingoftheRemoteControl
Devices,Safe-T-Beam®adjustment/cleaning,staplesthroughwiring, pinchedor broken
wires,Carriagedisengaged,ForceControladjustments,dooroutof balance,broken
springsor cables,poweroutages,useofextensioncords,missingordamagedpartson
discounted,clearanced,finalsaleor tapedcartons,phantomoperations(laborisnot
coveredif Openerisfunctioningproperlywhiletechnicianisin garage),fire,flood,or
actsofGod,orotherfailuretofollowtheOwner'sManual.
Pleasenote the following information,soit isavailableifyou
needto call us.
DatePurchased / /
SerialNumber*
Operator Model*
Dealer Name
DealerAddress
City
State / Zip
eeSerial Number islocated on the Power Head, inside
the Light Cover.
WK YR P I'_
Serial/Mfg No.
NOTE
Pleasekeep original or photocopy of your salesreceipt
with this manual for future reference shouldservice
ever be required.
INCLUDED IN THIS PACKAGE
Manual 1)Warranty Information
2) Pre Installation Checklist to be reviewed
prior to any assembly or installation
3) Necessary Adjustments
4) Programming Remote Devices
5) Maintenance and Troubleshooting
6) Parts Explosions
7) Accessory Order Form
8) Door Opener Association Safety and
Maintenance Brochure (DASMA)
9) Entrapment Warning Label- To be Adhered
in close proximity to wall control
Poster 1) Pictorial and step by step opener assembly
instructions
2) Pictorial and step by step opener installation
instructions
MARKED CLEARLYIN BOTH THE MANUAL
lAND POSTER ARE READ, UNDERSTOOD AND
FOLLOWED;
Visit Our Website at: www.geniecompany.com
FORANSWERS:CALL1.800.354.3643
SAVE THESE INSTRUCTIONS
2 For Help, call 1=800-3S-GENIE or visit www.geniecompany.com
OVERVIEW OF POTENTIAL HAZARDS
Overhead doors arelarge,heavy objects that movewith the help of springsunder high tension andelectric motors. Sincemoving objects,springs
undertension, andelectric motors cancauseinjuries, your safetyand the safety of others depend on you readingthe information inthis manual. If you
havequestions or do not understand the information presented, callTheGenie Company. or your localGenieDistributor.
In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safety
information. The word:
DANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury or property damage.
The word NOTE is used to indicate important steps to be followed or important considerations.
POTENTIAL HAZARD
MOVING DOOR
ELECTRICALSHOCK
HIGH SPRINGTENSION
EFFECT PREVENTION
WARNING: . Keep people clear of opening while door is moving.
Could result in death oDo Not allow children to play with the door operator.
or serious injury, oDo Not operate a door that jams or one that has a broken spring.
WARNING:
Could result in death
or serious injury.
WARNING:
Could result in death
or serious injury.
oTurn off power before removing operator cover.
oWhen replacing cover, make sure wires are not pinched or near
moving parts.
oOperator must be properly grounded.
. Do Not try to remove, repair or adjust springs or anything to
which door spring parts are fastened, such as, wood blocks,
steel brackets, cables or other like items.
oRepairs and adjustments must be made by a trained door
system technician using proper tools and instructions.
MPORTANT INSTALLATION
NSTRUCTIONS
WARN ING:
TO REDUCE THI RISK
OF SEVERE INJURY OR DEATH:
1 READAND FOLLOWALL SAFETY,INSTALLATIONAND OPERATION
INSTRUCTIONS.If you have any questions or do not understand
an instruction, call your authorized Genie installation professional.
2 Do Not install operator on an improperly balanced door. An
improperly balanced door could cause severe injury. Repairs and
adjustments to cables, spring assembly, and other hardware
must be made by a trained service person using proper tools
and instructions.
3 Remove all ropes, and disable all locks connected to the door
before installing operator.
4 Install door operator 7 feet or more above the floor. Mount the
emergency release knob 6 feet above the floor.
5 Do Not connect the operator to the source of power until
instructed to do so.
6 Locatethe control button:
Within s!ght of door.
At a minimum height of Sfeet, so small children cannot reach it.
Awayfrom all moving parts of the door.
7 Install the entrapment WARNINGlabel next to the wall button or
console. Install the emergency releasetag on, or next to, the
emergency release.
8 The operator must reverse when the door contacts a 1-1/2 inch
high object on the floor at the center of the doorway. This is
about the size ofa 2 x 4 board aid fat.
SAFETY FEATURES
Safe-T-Beam® (STB)Non-Contact
Reversing System
Placesan invisiblebeam acrossdoor opening, that
reversesthe door during down travel to the fully
open position if anything passesthrough beam.
Safe-T-Reverse® Contact Reversing System
Automatically stops and reversesa closing door
within 2 secondsof contact with an object.
Safe-T-Stop® Timed Reversed System
Automatically opens a closing door, ifdoor does not
close within 30 seconds.
ForceGuard Control
Used to set the force required for opening and clos-
ing door. Formaximum safety,set the minimum
force required to fully open and close door.
Automatic Lighting System
Light bulbs up to 60 Watts max., used for safer
entries and exits. The lights turn on when door
isactivated and automatically turn off 4.5
minutes later.
Manual Emergency Release
Allows the garage door to be opened or closed
manually for emergencies or maintenance.
For Help, {all 1-800-35-GENIE or visit www.geniecompany.com :3
PRE=INSTALLATION CHECKLIST
This Opener includes parts and supplies neededto install in most
garages and connect to most garage doors. There are many variations
of garagesand garage doors. A few additional parts and supplies may
be needed to install Opener into your garage and connect to your
garage door. While checking items listed below, note any additional
items you will need.
Tools used in this section:
12% Tape Measure Pencil Ladder Level
Check following items before assembling Opener:
Checkcondition of vertical stile in center of door, and its connection to
door's top and bottom beams. (Figure 1)
A If door frame isnailed together and not a solid connection, door
frame must be bracedor reinforced before installing Opener.
B If door is"lightweight" (madewith frame and skin - not solid),
door (including door frame) must be braced or reinforced before
installing Opener.
C A door opener reinforcement bracket may alsobe needed to
connect garage door to Opener's Door Bracket. This Opener is
designed for installation on a properly braced sectional door or
solidly braced one-piece door.
D Contact your Genie FactoryAuthorized Dealeror dealer of your
garage door for any necessarybracing and adoor opener
reinforcement bracket (if needed) before proceeding.
E If you have a wooden door, measuredoor's thickness. Ifyour door
is lessthan 2" thick, brace door or useshorter Door Bracket LagScrews
(1/4" x 1-1/4"- not included)
AND BALANCE
A Raisedoor, check alignment and seeif it movesfreely (Figure 2).
Ifdoor appears out of alignment, binds, or does not move smoothly,
contact a Genie Factory Authorized Dealeror dealer of your garage
door for repairsand adjustments to door mechanism.
B Raisedoor to 3' - 4' above ground and carefully let go. Door
should staystationary. Slight movement isacceptable. More than
slight movement meansdoor isout of balance. Contact aGenie
FactoryAuthorized Dealeror dealer of your garage
door for repairsand adjustments to door mechanism.
....::::-:::::: KEEPFEET CLEAR OF DOOR
One-Piece
Door
Figure 2 Checking door balance
WARNING:
Ifyour door sticks, binds, or isout of balance, have it adjusted
bya Genie Factory Authorized Dealer. Door springs,cables,
pulleys,brackets and associatedhardware are under extreme
tension and cancause seriousinjury or death.
4
C Checkdoor type. Makeanoteofwhetheritisasectionalora
one-piece door for reference later (Figure 2).
SECTIONAL DOOR,TORSION SPRINGS SECTIONAL DOOR, EXTENSION SPRINGS
ONEPIECEDOOR,TRACKLESS
Header Area
Center Stile
Figure 1 Note Door Type
A Measuredoor height (floor to top of door) using atape measure.
B This new GarageDoor Opener isdesigned for doors up to and
including 7' 6"tall. If door height is7' 6" or lesscontinue to CheckStep 4.
C If door height is8'-0", you need a RailExtension Kit.(Figure 3).
(SeeAccessoriesOrder Form,Page16).
D If the door height istaller than 8'-0",
the opener you purchased isthe Rail Extension for
wrong version. Contact 8' door
Customer Service
Representative
at 1-800-354-3643.
Figure 3 Rail Extension Kit
NOTE
The header is a heavily reinforced section of the wall just
above the top of the garage door opening.
A Findvertical center lineof door and header:
Closedoor.
Measuredoor width at top.
Marka point at center of door and on headerdirectly
above door. Drawacenter lineto connect points.
B Find Header Bracketmounting height (Figure 4): (Do not attach
Header Bracket).
Raisedoor, watching top edge of door and stop door
when its edge reachesits highest point.
Measuredistance ("H") from top edge of door to floor.
- Forsectional doors, add 2-1/2" to "H". Mark a point
on center line. Bottom of Header Bracket will be
installed here.
- Forone-piece doors, add 6" to "H". Markthis point on
center line. Bottom of Header Bracketwill be
installed here.
SECTIONAL DOOR
H÷2_J=2_......
H
ONE-PIECE DOOR
Figure 4 Find Highest Point of Travel
ForHelp,call 1-800-3S-GENIEorvisit www.geniecompany.com
NOTE
For all types and styles of doors:
- If the ceiling in your garage isso low that there is
not at least a 3" space above the Header Bracket
mountingpoint, contact a Genie Factory
AuthorizedDealer.
Ifa door spring is in the way, place the Header Bracket
above the spring. Do Not move the door spring.
WARNING:
Door springs are under extremely high tension and
shou d be handed ONLYby atrained professiona.
C Checkwall for astud or a solid headerat your mark: (If checking a
finished wall, astud finder may be helpful).
If location isabove Header,a 2"x 6" board must be
screwed to studs besideyour mark with at leasttwo Lag
Screwsand FlatWashers(not provided).
Transferyour markto new mounting board.
Check ceiling or space above where Opener Power Head will be
mounted (Figure 5): There must be a 120Volt grounded outlet or
wiring box within 3 feet of Power Head.
Grounded
outlet
1
(8' door)
Door Center Line
Figure S Check Power Head location
A The measurements above aretaken from the garage door
centerline toward the rear of the garage.
B Find location of ceiling joist or truss above where Opener Power
Head will beand estimate type and quantity of materials needed for
your installation (Figure 6A & B).
MOUNTING EXAMPLES
Standard Straps
Extra wood required Perforated Angle
Iron
Figure 6A
OPENCEILINGSStrapsand angle iron may attach directly to joists
or trusses.
For Help, call 1=800=35=GENIEor visit www.geniecompany.com
Perforated Straps
FINISHEDCEILINGS
Locateceilingjoistsortrussesusing
astudfinderorsimilardevice.
Attach angle iron(not included)
to joists or trussesthrough finish
material using LagScrews.
Figure 6B Mounting methods for open beam or finished ceilings
POWERSOURCE
A Checkthat there isa 15Amp 120 Volt grounded electrical
outlet or grounded permanent wiring box (per building code)
within 3' of Opener Power Head(Figure S).
If not, an outlet or wiring box must be installed. Contact
a licensedelectrician for installation.
Ifbuilding codes require permanent wiring, Power Head
must be partially disassembledto install appropriate
wiring in place of PowerCord. (SeeAssemblyand
Installation Poster.)
NOTE
Permanent wiring must be installed by a Licensed
Electrician. Not all Genie Factory Authorized Dealers are
Licensed Electrician's. Contact someone who isa Licensed
Electrician.
WARNING:
Do not use and extension cordi Extension cords Can cause
dangerous overheating COnditions:
Do NOt Use p0rtable generat0rs: This pr0duct isdesigned
to operate on standard house current;
DoNot use alternate power supplies.
MOU_ lJ.......... n ......., ......NNTINGBRACKET LOCATIO
Check for wood garage frame, jamb, or masonry at mounting
location (6" above floor) with attachment tabs facing away
from garage door (Figure 7).
A If you cannot mount Safe-T-Beam ®Mounting Bracket to
wood frame:
. Concrete screws and concrete anchors (not included)
must be used to mount Brackets on masonry with
attachment tabs facing away from garage door.
Safe-T-Beam®Mounting Bracket Extensions may be used
(not included -available at Dealeror useorder form pg. 14.
I
_i_ / ...........: Topof
Safe-T-Beam ®
Bracket
Mounting Bracket@/_ / 6"
_i _rr above
Figure 7 Mounting I floor
Safe-T-Bea _......
Components
5
A Tools(FigureS):
B Additional tools to make installation easier:
Slotted and phillips screw-driver bits
Stud finder
Sheet-metal cutting snips
Check that the garage door locks, rope, and T-Handles are
removed from the garage door before starting the installation.
A If your garage does not have a separate entry door, it is
highly recommended to install a Genie Emergency Release Kit
(GER-2). Emergency Release Kit lets you open the garage door
from outside if there is a power failure. (Please see Accessories
Order Form on page 14.)
Before going further, get any items and tools if needed
for your installation
Garagedoor frame reinforcement brackets, screws, bracing
or reinforcement kits (dealer)
LagScrews(1-1/4") for a wood door lessthan 2" thick (store)
Electricaloutlet and/or wiring (supplied by a licensedelectrician)
Sufficient angle iron or strapping for hanging Power Head(store)
60 Watt light bulbs (Rough service bulbs recommended)(store)
GER-2EmergencyReleaseKitfor entry during power failure (store)
Wood for header, ceiling, and/or door braces(store)
®
Masonry fastenersfor Safe-T-Beam Bracket installation (store)
Safe-T-Beam®Bracket Extensions(dealer)
Masonry drill bit (store)
Extension Kit (for 8' GarageDoors)(dealer)
Go to Assembly and Installation Poster for full
Installation Instructions.
Adjustable Wrench
Hammer
1t16" 5/32" Tape Measure'_
Drill Bit Drill Bit
Wire
Stripper
Safety Glasses
Phillips Screwdriver
Flat Blade Screwdriver
CF i_ ::: :: ....................
Pencil
Hack Saw
Wrench
1/4" 5/I6" 3/8" 7/16" 1/2" 9/16"
Sockets
6
Carpenter's Level
Figure 8 Recommended Tools
IMPORTANT
SAFETY INSTRUCTIONS
!LWARNING:
TO REDUCE THE RISK OF
SEVERE iNJURY OR DEATH
1 READANDFOLLOWALLINSTRUCTIONS.
2 Neverletchildrenoperateor playwith the DoorControls.Keep
theRemoteControlawayfrom Children.
3 Alwayskeepthe movingdoor insightand awayfrom peopleand
objectsuntilthedoor iscompletelyclosed.
NOONESHOULDCROSSTHEPATHOFA MOVINGDOOR.
4 NEVERGOUNDERA STOPPED,PARTIALLYOPENDOOR.
5 TestOpenermonthly. The,door MUSTreverseoncontactwith
a 1-1/2 highobject (ora 2 x4 boardlaidflat)atthe centerofthe
doorwayonthefloor. Afteradjustingeitherthe Forceorthe Limit
oftravel,retestthe DoorOpener Failureto adjustthe Opener
properlymaycausesevereinjuryordeath.
6 Whenpossibleusethe EmergencyReleaseony whenthedoor
isclosed.Usecautionwhenusingthis Releasewith dooropen.
Weakor brokenspringsarecapableofincreasingthe rateofdoor
closureand increasingthe riskofsevereinjuryordeath,
7 KEEPGARAGEDOORSPROPERLYBALANCED.SeeOwner's
Manual.An improperlybalanceddoor increasestheriskof severe
injuryordeath. HaveaGenieFactoryAuthorizedDealermake
repairsto cables,springassemblies,andother hardware,
8 SAVETHESEINSTRUCTIONS.
NOTES, REMINDERS
AWARNING
use the Wall Console induded_ith opener:Any, other wall
console can causethe Opener to operate unexPectedly and the
light to stop working. 1
For Help, call 1-800-35-GENIE or visit www.geniecompany.com
_DJUSTMENTS
SET LIMIT SWITCHES AND
FORCECONTROLS
Coarse Setting of Limit Switches
A Setting Close Limit Switch
. Check that Carriage Assembly is disengaged.
. With garage door fully closed, slide Close Limit Switch
until it is aligned with the center of the
Carriage Assembly.
. Tighten Set Screw. Do Not over-tighten.
B Setting Open Limit Switch
. Manually open garage door to full open position.
. Slide Open Limit Switch until it is aligned with the center
of the Carriage Assembly.
. Tighten Set Screw. Do not over-tighten.
. Re-engage Carriage Assembly.
Setting Force Controls and Final Adjustment of
Limit Switches
i, Thegarage door opens rapidlyi and Cancause serious
: injury or deathl
; Keep the path Clear:
' Position the ladde[ to the Side of the Power Head Soit iS
Clearofall moving parts ofthe Opener and the door,
Set the dooi Opener to use the minimum force needed
to open the door.
CLOSEADJUSTMENT
On front panel of Power Head find adjusting screw
marked "CLOSE" (Figure 9).
Gently turn screw counterclockwise until it stops.
- Very little force is required to turn adjusting screw.
Press Wall Console to close garage door.
- Observe if door stops at "CLOSE" limit switch.
If door is fully closed--adjustment isfinished.
Go to "OPEN" Adjustment.
- If door stops but is not fully closed,
a. Measure distance between bottom of door
and floor.
b. Move "CLOSE" Limit Switch that same distance
toward door.
- If door stops and/or reverses before reaching the
"CLOSE" Limit Switch
a. Slightly increase CLOSEForce setting (clockwise).
- If door reverses after contacting floor, move Limit
Switch toward Power Head.
- If door fails to move, check Safe-T-Beam ®System. See
Troubleshooting Section, pages 10 and 11.
A
o
NOTE
Little effort isrequiredto turn the ForceAdjusting Knobs.
Ifthe door stops moving while opening or closing,adjust the
Open Forceor CloseForceControlsslightly clockwise(to
slightlyincreasethe force) and retry the step.
TheOpen Forceand CloseForceControlsare to be setto the
minimum force necessaryto ensurethe door smoothly opens
and closescompletely.
Ensurethe CarriageAssemblyisengaged andisbetween the
two Limit Switches beforeoperating the Opener.
Thegaraged0oi Opensrapidly;and can causeSeiOus
injury Ordeath:
Keepthepath clear:
Positionthe ladder to the sideOfthe Power Headsoit
is earof al!mo_ing parts ofthe Opener and the door
i; Setthe door opener to usethe minimum force needed
to open the door:
IB OPEN ADJUSTMENT
On front panel of Power Head find adjusting
screw marked "OPEN" (Figure 9).
Gently turn screw counterclockwise until it stops.
- Very little force isrequired to turn
adjusting screw.
Press Wall Console to open garage door.
- Observe if door stops at "OPEN" limit switch.
If door isfully open--adjustment isfinished.
- If door stops but isnot fully open,
a. Measure distance between bottom of
door and top of door opening.
b. Move"OPEN" Limit Switch that same
distance toward Power Head.
- If door stops before reaching the "OPEN"
Limit Switch
a. Slightly increase OPEN Force
setting (clockwise).
- If door fails to move, see Troubleshooting
Section, pages 10 & 11.
C Run Door Opener
Cycle opener afew times to double check
settings. Repeat adjustment steps as necessary.
OPEN
FORCE ...
LOCATED
UNDER
LIGHT
COVER
CLOSE /
FORCE
CLASS 2 SUPPLY
18-30 VOLTS
Figure 9 Making Force Adjustments
(Located Lower Right Corner).
For Help, call 1-800-35=GENIE or visit www.geniecompany.com 7
SETTING CONTACT
REVERSEFUNCTION
NOTE
Limit Switchand ForceAdjustments must be completed before
checkingthe contact reversefunction.
A Open garage door using Wall Console.
B Lay a 2" x 4" board flat in center of doorway (Figure 10).
C Close door using Wall Console.
D Check that door stops and reverses within 2 seconds after it
contacts board:
If door does not reverse, decrease Close Force until
door reverses (Figure 9).
If door still does not reverse, move Limit Switch
toward door.
E Check Safe-T-Beam ®System operation:
If beam is blocked, door
will not close.
Figure 10 F
Checking _J
2" x 4" board
Contact
/J_-_ laid flat
Reverse
NOTE
The door must contact the 2" x 4" board before the
Carriage activates the Close Limit Switch. If not,
readjust the Close Limit Switch.
ACCESSORIES
PROGRAMMING THE
REMOTE CONTROL
A To program one Button of a Remote Control (Figure 11):
Locate Learn Button and Learn Indicator Light near
Terminal Block on Power Head (Figure 12).
Press and release Learn Button. Red Learn Indicator Light
will blink 2times per second.
Press Remote Control Button once within 30 seconds. Red
Learn Indicator Light will stay lit.
Press Remote Control Button again. Red Learn Indicator
Light will go out, indicating that memory isstored.
Press again to Activate Unit.
B Program each additional Remote using step A above.
To Erase All Remotes from Power Head Memory
A Press and hold Learn Button on Power Head for 10 seconds
or until Learn Indicator Light goes out. Memory is erased:
Program Remotes again as needed.
To Replace Remote Control Battery
A FOR NON-FLASHLIGHTMODELS
Pop off the back of the transmitter.
- Use coin, pen, screwdriver or any similar device.
- Replace old Battery with new coin type battery.
o Replace back of remote.
B FOR FLASHLIGHT MODELS
Slide open battery cover.
- Replace old Battery with new AAA battery.
o Replace battery cover.
A WARNING
Amoving garagedoormaycauseserious njuryor death.
--_ Keeppeopleclearof openingwhile door ismoving.
Donot allowchildrento playwith the RemoteControls,
Ifthe SafetyReversedoesnot work properly:
" Closethedoor anddisconnecttheOpenerusingthe
EmergencyReleaseCord.
, Donot usethedoor Opener,RemoteControls,or
WirelessKeypad.
Referto thedoor anddoor0 penerOwner'sManuals
beforeattempting anyrepairs.
Remote Control Operation
A
B
Figure 1 1
1-Button and 3-Button
Compact Remotes
w/Docking Station
PressButton on Remote Control. Garage door will move.
Press Button again. Garage door will stop:
The door automatically stops at the end of the
open or close cycle.
Press Button again. Garage door will reverse.
D There are several additional varieties of remote controls
available from your local dealer, some equipped with
a flashlight.
LOCATED
UNDERTHE
LIGHT COVER
_b
©
....@(h
CLOSE@ MOREFORCE
©
LEARN
INDICATOR
_-- LIGHT
---- LEARN
CODE
BUTTON
Figure 12 Learn Code Button and Indicator Light.
(Located Lower Right Corner).
NOTE
e
Each Remote Control must be programmed
separately.
The Remote Controls will not close the garage with
malfunctioning Safe-T-Beam®System.
Program Remote Controls, while at least 24" from
Antenna Wire.
If the red Learn Indicator Light blinks rapidly,
programming stopped. Restart programming.
Each Button on a multi-button Remote Control is
for a different Opener. Cannot use more than one
Button for same Opener.
A maximum of seven Remote Controls or Wireless
Keypads can be stored into the Receiver at one
time. If a Remote Control becomes lost, or if you
want to delete a Remote Control or Wireless
Keypad, see "To EraseAll Receiver Memory."
8 For Help, call 1-800-3S-GENIE or visit www.geniecompany.com
iNSTALLATiON OF LENSAND BULB
A Install a light bulb (1O0Watts or less)(not included) into Light
Socket (Figure 14):
Rough service, 130 Volt bulbs are recommended.
B Install Lens into slots in Motor Cover.
Insert Bottom hinges into slots provided in metal front
cover of Power Head.
Flip Lensup and fasten with molded latches on lens.
Figure 14 Install Lens and Light bulb
NOTES
Transmitter Compliance Statement
Transmitters comply with all United States and Canadian legal requirements as of the
date of manufacture No warranty is made that they comply with all legal requirements of
any other jurisdiction.If transmitters are to be used in another country, the importer must
determine compliance with any local laws and regulations which may differ from United
States and Canadian requirements prior to use.
Los transmisores cumplen con todas las reglamentaciones [egales de los Estados Unidos y
del Canad&, en [a fecha de fabricaci6n. Ninguna garantfa se da que cumplan con todas as
reglamentaciones legales de ninguna otra jurisdicci6n. Si los transmisores se van a utilizar
en otro pals, el importador debe determinar si cumplen con las reglamentaciones y [eyes
locales que puedan ser diferentes a las reglamentaciones de los Estados Unidos y del
Canad& antes de usar los mismos.
Les emetteurs sont conformes _ la reglementation am_ricaine et canadienne _ compter
de leur date de fabrication. Aucune garantie n'est stipul6e indiquant qu'ils sont conformes
routes [es prescriptions juridiques d'autres autorit_s. Si les _metteurs sont utilis_s dans
d'autres pays, i[ incombe a I'importateur d'en d_terminer leur conformit_ aux lois et
regles locales pouvant diff_rer de celes des Etats-Unis et du Canada avant toute
utilisation desdits _metteur£
Sendeger_ite entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum
Zeitpunkt der Herstellung,Wir Obernehmen keine Gew_ihrleistung for die Einhaltung aller
gesetzlichen Bestimmungen in anderen Lindem. Sollen Sendegerite in anderen L_ndem
eingesetzt werden, so muss der Importeur vor dem Gebrauch sicherstellen, dass die
Sendeger_te auch solchen Iokalen Bestimmungen entsprechen, wekhe yon den
Bestimmungen der USA und Kanadas abweichen.
nlF+-t iOl 71El Ef-_--_ xlgqlAt +,"-f&_-I _-,'q:>- _-_°_;q_i,q_SFTlO_l o_,,ti _lq_t _HI-F.F_P--IS_
F&_,_I _l-@_Cl_____ :::z _Cl c" I _'_f __allOtl [qe-l-oi: _;q°l o:i _ z_oHof
IMPORTANTSAFETYINSTRUCTIONS
WARNING--
TO REDUCE THE RISK OF
SEVEREINJURY OR DEATH
1 READAND FOLLOWALLINSTRUCTIONS.
2 Never let children operate or play w th the Doo_
Controls. Keepthe Remote Control away from children.
3 Always keep the moving door in sight and away from
people and objects until the door iscompletely closed.
NO ONESHOULD CROSSTHE PATH OFTHE
MOVING DOOR.
4 NEVERGO UNDERA STOPPED,PARTIALLY
OPENDOOR.
5 TestOpener monthly,. The door MUST reverse on
contact with a 1-1/2 high object (ora 2 x 4 board
laid flat) at the center of the doorway on the floor. After
adjusting either the Forceor the Limit of travel, retest
the Door Opener. Failureto adjust the Opener properly
may causesevere injury or death,
8 WhenpossibleusetheEmergencyReleaseonlywhen
the door isc osed. Usecaution when using this Reease
with the dooropen. Weakor brokenspringsarecapable
ofincreasingthe rateofdoor closureandincreasingthe
riskofsevereinjuryor death.
7 KEEPGARAGEDOORS PROPERLYBALANCED. See
Owner's Manual. An improperly balanced door increases
the risk of severe injuryor death. HaveaGenie Factory
Authorized Dealermake repairsto cables,spring
assemblies,and other hardware.
8 SAVETHESEINSTRUCTIONS.
For Help, call 1-800-3S-GENIE or visit www.genie¢ompany.com
SCHEDULED MAINTENANCE
A
o
Monthly:
Door springs and door hardware:
- Oil door roller, bearings, and hinges using silicone
lubricant or light oil.
A WARNIN J
--Do not operate door auto atiCally 0r man_al/y if Springs
are broken, Contact a Genie Fact0ry Authorized Dealer for
service or call Customer Service at 1,800,35'GENIE. !
Balance Door.
- Close door.
- ReleaseCarriage Assembly from RailAssembly by pulling
down on Emergency Release Knob.
- Raisedoor manually 3'- 4' and verify that door stays at
that position. See Check Step 2 on page 4.
NOTE
When the door is3'- 4' above the ground, the door
should stay open. Slight movement isacceptable. If
the door moves too much, contact a Genie Factory
Authorized Dealer for service or call Customer Service at
1=800=35=GENIE.
Reattach Carriage Assembly to RailAssembly:
a. Pull the Emergency ReleaseKnobtoward
Power Head.
b. Close door.
Contact Reverse Test,
- Perform Adjustment Step 2 on page 8.
AWARNING
Ifthe door fails to reverse on contact with the board,
adjust the Close Force Control as specified in Set Limit
Switches and Force Controls on page 9. If the Opener still
fails, contact a Genie Factory Authorized Dealer for service
or call Customer Service at 1-800-35-GENIE.
FCCAND IC CERTIFIED
All devices comply with Part 15 of the FCCRules.
Operation is subject to the following two conditions: (1)
this device may not cause harmful interference,and (2)
this device must accept any interference received, includ-
ing interference that may cause undesired operation.
B As Needed:
Replace Light Bulb
TROUBLESHOOTING GUIDE
Safe=T=Beam ®System Self=Diagnostic Troubleshooting
Source (Red LED)
ON
OFF
OFF
2 BLINKS, Pause
(Repeat)
2 BLINKS,Pause
(Repeat)
3 BLINKS,Pause
(Repeat)
4 BLINKS, Pause
(Repeat)
Sensor (Green LED)
ON
OFF
ON
ON
OFF
ON
ON
Possible Problem
Normal operation
o Power Head not powered
oWiring from Power Head bad
o Wiring to Source missing or bad
o Power has been interrupted
o Beam not aligned
o Beam obstructed
o Sensor defective
o Wire to Sensor missing or bad
o Sensor defective
o Sensor receiving interference
. Source not sending pulses
. Source defective
Solution
None required
. Check breakers, fuses, plugs
. Check wiring for obvious shorts
. Check wiring
. Remove power and reapply
. Check Source, Sensor alignment
. Check for obstruction
. Contact Customer Service
o Check wiring
o Contact Customer Service
o Determine source of interference
o Check for sunlight or another
opener on nearby door
. Contact Customer Service
o Contact Customer Service
. Contact Customer Service
10 For Help, call 1=800-35-GENIE or visit www.geniecompany.com
Problem
Openerdoesnot run
from WallControl
Door Opener starts
for no apparent reason
Door starts down, then
stops before it is
completely closed
Door starts down, then
stops and goes backup
Door will only run closed
Doorwill onlyrunopen
Lightswill not turn off
Doorstartsup,
but stopsbeforeit is
completelyopen
Operator runs,but door
doesnot move
WallConsoleVacation
Lockfunction does
not work
Noisy Operation
General Troubleshooting
What To Do
1. Check Lock switch on Wall Control Installation Poster.
2. Check Power Source:
For Grounded Plug Connection.
- Plug a lamp into the electrical outlet used for the door opener.
a. If lamp lights, power source is good.
b. If lamp does not light, check fuse or circuit breaker.
For Permanent Wiring Connection.
- Check fuse or circuit breaker.
3. Check connections (seeWall Console Installation on Installation Poster):
At Power Head Terminals and Wall Control.
1. Check Wires to ensure that they are not cut (Staples can cut insulation and short Wires)
Replace any shorting Staples and shorted Wires.
2. Was Remote Control lost or stolen? If so,erase all Remote Control codes from Receiver's memory
and reprogram for remaining remote controls. (See EraseAll Receiver Memory on page 8).
3. Ensure that no Buttons are stuck "pushed-in" on Wall Console or any Remote Controls.
1. Check Close Limit Switch setting (page 7 and poster). Adjust asneeded.
2. Check ForceSetting (pages 7).Adjust as needed.
3. Check for shorted wires.
1. Ifa new installation, check Door Arm position.
2. Checkoperation of Contact Reversefunction.
3. CheckSafe-T-Beam®Systemfor beam obstruction or misalignment of Lenses.
4. CheckSafe-T-Beam®Systemdiagnostic code.
5. CheckCloseForceadjustment (seeSet Limit Switchesand ForceControlson pages7). Adjust asneeded.
6. Checkgarage door for binding.
1. CheckOpen Limit Switch for a short circuit and for proper wiring.
2. CheckOpen Force adjustment (seeSetLimit Switches and ForceControls on pages 7).Adjust asneeded.
3. Checkcondition of garage door and door spring(s).
4. WARNING: If you suspecta problem with the garage door hardware or springs,contacta Genie
FactoryAuthorized Dealer for service,or contactCustomer Serviceat 1-800-35-GENIE.
5. CheckPositionof LockSwitchon Console.
1. CheckSafe-T-Beam®Systemasdetailed in the Safe-T-Beam®SystemSelf-diagnosticTroubleshooting Chart
(page 10).
2. CheckCloseLimit Switchfor a short circuitand for proper wiring.
3. CheckCloseForceadjustment (seeSet Limit Switchesand Force Controlson pages7). Adjust asneeded.
1. Disconnect WiresconnectingPushbutton to Power Head(seePushbutton Installation on poster).
Checktheir conditionand either replaceor reconnect.
2. Until areplacement WallConsolecanbe obtained, disconnect Wall Consoleand useonly Remote Controls
or WirelessKeypadto operate Opener.
3. Checkfor non-compatible wall control.
1. Check(ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced asdetailed in Maintenance Section.
2. WARNING: If you suspecta problem with the garage door hardware or springs,contacta Genie Factory
Authorized Dealer for service,orcontact Customer Serviceat 1-800-3S-GENIE.
3. CheckOpen Limit Switch for ashort circuitand for proper wiring.
4. CheckOpen Forceadjustment (seeSetLimit Switchesand ForceControlson pages7). Adjust asneeded.
1. EnsureCarriageAssembly isengaged to CarriageSlide(seeInstallCarriageAssemblyontoRailsonInstallationPoster).
2. CheckForceadjustment (seeSet Limit Switchesand ForceControlson pages9and 10). Adjust asneeded.
1. EnsureCarriageAssemblyisin contactwith CloseLimit Switch.
2. Checkwhen door isfully closed,that CarriageactivatesCloseLimit Switch. Ifnot, adjust position of Close
Limit Switch (Seepages7).
1. Besureall fastenersaretight.
2. Check(ensure) that garage door and Opener are in good repair, properly lubricated, and properly
balanced asdescribed in Maintenance Section (page 10).
For Help, call 1-800-35-GENIE or visit www.geniecompany.com 11
PARTS iDENTIFICATION
Head List Number
Power Parts _.auded
[1]Power Head Assembly Item Part Name
.1 Power Head Assembly 1
* 1A Cover (by Series Model) 1
* 1B Front Panel Assembly 1
* 1D Motor Parts 1
* 1E Circuit Board Assembhz 1
* 1F Capacitor (By Series/Model) 1
1G Opto Wheel (not shown) 1
* 1H Carriage Slide 1
* 1J Chain 1
1K Circuit Board Bracket 1
* 1L Drive Module 1
* 1M Terminal Strip 1
* 1N No. 8-32 x 3/4" Hex Head Screw
w/int. Lockwasher 1
1P Shock Absorption Stop 1
* 1Q Motor Mount Bracket (not shown', 1
1X Chassis 1
4 1/4-20 Shoulder Bolt 1
5 1/4" Flange Nut 1
39 Coupler 1
41 No. 8-32 x 3/8" Phillips
Hex Head Screw 1
42 No. 8-32 x 3/8" Phillips
Pan Head Screw 1
48 Mountinq Straps 2
49 Light Lens 1
* Pre-assembled
WIRING DIAGFIAM [ A Shut 0ff Cower bef0re 0penilg the cdver:[Components inside Cover May Cause Electric Shock J
RED
ORANGE
2
SEQUENCER HOUSING
, M°L°R.
I I
, _,_
I THERMAL _ _i:Y I [
] PROTECTOR [ "_ ,,,,,(::_ i [
BLACK ' _ _'_/ I _ MOTOR
i I
;RED YELLOW',
i j
J
POWER CORD
YELLOW YELLOW
z
/_7 _
®®®o6®®®@®®®
WHITE BLUE
LIGHT
POWERHEAD TERMINALS
WALLCONTROL
OPENLIMIT
COMMON
OPIN
IIM] SWITCH
(JO'l
CLOSELIMIT
[_. LMIT SWTCH
12 For Help, call 1-800-35-GENIE or visit www.geniecompany.com
PARTS i DENTIFICATION
[2]RailAssembly
\
Parts List
item Part Name
1 PowerHead Assembly (main box)
2 RailAssembly (1-piece)
4 RailAssembly_3:piece)(main box)
5 First RailSection (separate box)
6 Middle RailSection (separate box)
7 End Railsection (separate box)
8 RailClamps (blue bag)
9 1/4"-20x 5/8" HexHead Bolt (blue bag)
10 1/4"-20" Hex Flange Nut (blue bag)
11 Carriage Assembly (main bag)
12 RailStrap (blue bag)
13 Limit Switch (white wire)(blue bag)
14 Limit Switch (brown wire)(blue bag)
15 ReleaseCord (green bag)
16 ReleaseKnob (green bag)
17 Emergency ReleaseTag(green bag)
18 HeaderBracket orange bag)
20 Door Bracket (orange bag)
22 1/4" x 2" LagScrew (orange bag)
23 Straight Door Arm (main box)
24 ClevisPin (yellow bag)
25 Cotter Pin (yellow bag)
26 Curved Door Arm (main box)
27 3/8"-16 x 7/8" H.H.Bolt (yellow bag)
28 3/8"-16 HexNan e Nut ( ellow ba )
29 Wire (main box)
30 Insulated Staples(red bag)
m
1
I
I
I
I
4
12
12
I
I
I
I
I
I
I
I
I
8
I
2
2
I
2
2
I
variesby
model
Parts List
item Part Name
31 Wall Button (red bag)
32 Wall Console (main box)
33 #6x 1-1/4" pan head phillips screw
34 Entrapment Warning Label (manual)
35 Safe-T-Beam®Sensor (main box)
36 Safe-T-Beam®Source (main box)
37 Safe-T-BeaM®Mountinq Brackets
38 Remote Controls (main box)
39 #8-32x 1" Machine Screw (green bag)
40 Safetyand Maintenance Guide (manual)
41 Wire Clips
42 1/4"-20 x3/4" Self-drilling Screws
(orange bag)
44 #10-16x 1-1/4" Phillips Hex HeadScrew
(yellow bag)
46 5/16"-18 x 3/4"Hex Head Bolt
(orange bag)
47 5/16"-18 Hex Flange Nut (orange bag)
48 Mounting Straps (main box)
m
variesby
model
varies by
model
variesby
model
1
1
1
2
variesby
model
2
1
variesby
model
3
4
3
4
2
For Help, call 1-800-3S-GENIE or visit www.geniecompany.com 13
GarageDoorOpenerAccessoriesOrderForm
Formulairedecommandodesaccessoirespourouvre-porte degarage
For additional accessories not shown, visit our website at www.geniecompany.com
pour lesaccessoires suppl4mentaires pas montr4, visiter notr_ site web _ www.geniecompany.com
(GKT-1-390) 1-ButtonCompactRemote-Allowsremoteoperationofgaragedoor.
1-BoutennerT_l_cornrnaadecornpacte- Permettreoperation_loign"deportedegarage.
P/N 36248R 536.50
(GiFT-I-390) 1-ButtonFlashlightTransmitter- RemoteControllerwithaFlashlight.
1-houtenner['_rnetteurde[arnpedepoche- Lecontr61eur_loign_avecdelampedepoche.
P/N 35657R 545.00
{GICT-3-390)3-Bu_enCornpactBernete-AIIowsremoteoperationof3garagedoors.
3=boutennerlaT_l_cornrnandecornpacte- Permettreoperation_loign'
troisportes de ara e. P/N 36223R 550.00
(GWC-2W) Deluxe WallConsole -OperatesGarageDoor.Independentlightcontrol. Securityvacationlock.
LaConsoledseluxe de Mur- Actionnela portedegarage.Commanded'_clairageind_pendante.
Interrupteurde verrouillagede s_curit&
P/N 35661R 535.00
(GWKPD)DualFrequencyWirelessKeypad-OperatesIntellicode'GarageDoorOpenerswithoutRemoteControl
orkey.
Syst_rned'ouvre-pertedegarage_claviersansfil- Actionnelesouvre-portedegarageavec
Intellicode'sanst_l_commandenicl&
(GLU-3)
550.00
55.00
(Gw-2)
(6PS-5)
P/N 35691 R
3/4 oz. ScrewDrive Lubricant-Ensuresproperequipmentwearprotection.
Laonza3/4 Lubricantde la vis-Garantircomponantexactparsyst_med_fenseversuser.
P/N 35218AS
UniversalWall Button- Providesadditional convenientinsideoperationofdoor.
Bouten mural universal -ActionneI'ouvre-portede I'int_rieurdu garage.
PerfectStep- Ensuresperfectparking.
Butoir PerfectStop- Permetde stationner_ laperfectiondanslegarage.
(GABXS)
P/N 35693R 53.75
P/N 35677R 54.00
BeltDriveExtensionKit-AnExtensionthatincreasesthetravelofabeltdrivenOpenerto
accommodateaneightfootdoor.
N_cessairedeprolongernentducoulisseau-Rallongedeprolongeantlacoursederouvre-porte
BeltDrivepouruneportede2,4m(8pi)dehauteur.
P/N 35663R
(LCGX-8) Chain Drive ExtensionKit- An Extensionthatincreasesthe travelofa ChainDrivenOpenerto
accommodateaneightfoot door.
N@cessairede prolongernent ducoulisseau -Rallongedeprolongeantlacoursede rouvre-porte
du conduitdechainpouruneportede2,4m(8pi) dehauteur.
532.00
P/N 35679R 532.00
(GSX-8) ScrewDriven Extension Kit- AnExtensionto increasetravel of ascrewdriven Operatorto accommodate
an eightfoot door.
N_cessairede taffonge du Screw Drive- Rallongede prolongeantla
coursedeI'ouvre-portepouruneporte de2,4m(8pi) dehauteur.(GIRU-lT) _-e_
(60WATT)Enhanced/RoughServiceLightBulb-Ensuresproperequipmentcompatability.
(GER-2)
P/N 35678R
Eclairagede50WATT-Garantircomponantexactparsyst_me.
P/N 26210A.S
Emergency Release Kit - Provides access to garage from outside in the event of
an electrical power failure.
N6cessaires de D4clenchement de secours - Len_cessaire de d_clenchement
de secours est con_upour vous permettre d'acc4der &votre garage depuis
I'ext_rieur en cas de panne de courant et Iorsqu'il.
P/N 35675R
532.00
52.73
520.00
STB
Adapter Brackets (2) - Used in conjunction with standard STBBrackets. They
provide additional clearance and mounting options.
Crochets d'adaptateur (2) - Utilis_ conjointement avec STBstandard reenter
les crochets, ils fournissent le d_gagement suppl_mentaire avec monter d'options.
P/N 34439R.S 54.37
How many?
Comment
beaucoup?
Ordering Instructions
No C.O.D.shipments. Please include check or money order,
made payable to The Genie Company. Do not send cash.
Allow 3-4 weeks for delivery.
1-800-354-3643. Please have part number and credit
card ready. Mail Order Form to: Genie Company, 22790
Lake Park Blvd, Alliance, Ohio 44601. We accept Visa or
Mastercard on phone orders only.
Please add local sales tax if you reside in one of the states listed.
Californla, Connecticut, Florida, Georgia, Illinois, Indiana,
Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
TOTAL ORDER $
SHIPPING & HANDLING $ 6.00
STATE SALESTAX $
GRAND TOTAL $
Instructions Commandant
Pasd'exp_dition centre remboursement.Veuillezinclure uncheque
ou un mandatbancaire,le payablefaitaThe Genie Company.
N'envoyez pasd'argent comptant. Accordezde 3 _4 semaines
pourla livraison.1-800-354-3643.Ayezsousla mainle num6rode la
pieceetcelui de lacartede credit.Mettre _la pastelearrngement
_:GenieCompany,22790 LakePark Bivd, Alliance, Ohio 44601.
Nousacceptonslescommandespar t_l@honeavec paiementpar
cartede creditVisaou Mastercard.
Veuillez indiquer les taxes de vente locales si vous r4sidez dans I'un des
_tats r4pertori4s ¢i-dessous.
California, Connecticut, Florida, Georgia, Illinois, Indiana,
Maryland, Massachusetts, Michigan, New Jersey, New York,
Ohio, Tennessee, Virginia, Wisconsin
COMMANDETOTALE $
MANUTENTIONETEXPEDITION $ 6.00
TAXEDEVENTE $
TOTALGLOBAL $
SHIP ORDER TO:
EXPEDIER MARCHANDISE POUR:
NAME / NOV
ADDRESS / ADRESSE
CITY / VILLE
STATE / ETAT
ZIP / CODE POSTAL
(Pricessubject to change without notice)
(Lesprix assujettissentpourchanger sansla notification)
14 For Help, call 1=800=35=GENIEor visit www.geniecompany.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

Genie 2020L User manual

Category
Garage Door Opener
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI