Hager WBMSLL is an extension unit for master devices WBMDUR, WBMDUPB, and WBME5A. It is suitable for indoor use only and requires a neutral connection for LED indication. The device can be used to extend the range of the master device and is compatible with Hager Rotoloc switch plates. It has a momentary-contact current of >10 mA and requires a miniature circuit breaker of max. 10 A for protection.

Hager WBMSLL is an extension unit for master devices WBMDUR, WBMDUPB, and WBME5A. It is suitable for indoor use only and requires a neutral connection for LED indication. The device can be used to extend the range of the master device and is compatible with Hager Rotoloc switch plates. It has a momentary-contact current of >10 mA and requires a miniature circuit breaker of max. 10 A for protection.

6LE007715B
01
WBMSLL
Slave / Extension unit
Hager Electro Pty. Ltd., Unit 17/2-8 South Street, RYDALMERE NSW 2116, AUSTRALIA
Safety instructions
Electrical equipment may only be installed and
assembled by a qualied electrician in accor-
dance with the relevant installation standards,
guidelines, regulations, directives, safety and
accident prevention regulations of the country.
Failure to comply with these instructions may
result in damage to the device, re or other ha-
zards.
These instructions are an integral component of
the product and must be retained by the end
user.
Design and layout of the device
(2)
(1)
(3)
Figure 1: Front view
(2)
(3)
(4)
Figure 2: Rear view
The terminal block must be mounted in either
its original shipped position or on the rear of the
module by means of the enclosed cable tie.
(1) Button with status LED
(2) Retaining lugs for Rotoloc® fastening
(3) pre-assembled terminal leads
(4) Terminal block
Function
Correct use
- Extension unit to master devices WBMDUR,
WBMDUPB und WBME5A
- Suitable for indoor use only, but no drip and no
spray water.
02 T +61 1300 850 253 F +61 1300 424 372 [email protected] hager.com - 12.2021
- Suitable for Hager Rotoloc switch plates only
Product characteristics
- optional LED lighting by neutral conductor
connection
Operation
The operation is to be taken from the instructions
of the main device.
Information for electricians
Installation and electrical connection
DANGER!
Touching live parts can result in an
electric shock.
An electric shock can be lethal.
Disconnect the connecting cables
before working on the device and cover
any live parts in the area!
ç
Connection diagram
Remote
A
WBMSLL
Neutral connection
is only required for
LED indication
always on
Active / L
Neutral
Remote
N
Figure 3: 1 way connection
to additional
Slaves
WBMSLL
A
N
WBMSLL
WBMSLL
WBMDxxx / WBME5A
Active / L
Load
Remote
Active / L
Neutral
Remote
Active / L
Neutral
Remote
Figure 4: Multi way connection
Neutral connection at the slave is only required
for LED indication always on.
Main device and extension unit must be installed
on the same phase.
Optional LED indication requires a neutral
connection off the same circuit as the master it is
connected to.
Install a miniature circuit breaker of max. 10 A as
device protection.
Technical data
Operating voltage 230 V~ +/-10%
Frequency 50 Hz
Momentary-contact current > 10 mA
Circuit breaker max. 10 A
Degree of protection IP2X
Power consumption
-Status LED Off
- Status LED On
< 0.07 W
< 0.3 W
Extension unit cable length
Load and extension unit cable
- in a common cable
- in separated cables
max. 20 m
max. 50 m
Terminal block cables max. 2 x 1.5 mm²
max. 1 x 2.5 mm²
Flying leads, fl exible 100 mm x 1,5 mm²
Operating temperature -5 … 50 °C
Storage temperature -20 … 70 °C
Relative humidity (without
condensation)
0 … 65 %
Troubleshooting
Unde ned interferences during operation
Extension unit cable length too long or or a separa-
ted extension unit cable has not been used.
Adhere to extension unit cable length or use
separate extension unit cable if necessary
End of life treatment of electrical/
electronic equipment and batteries
in the European Union countries.
The crossed-out ‘wheeled bin symbol’ marked on
the equipment or its packaging, indicates that this
product is not to be disposed off with unsorted
municipal / household waste. Please check with
your local authority or retailer for recycling and
collection advice. This will enable you to contribute
to the disposal, treatment and recycling in an
environmentally sound way and help to prevent
potential negative effects on the environment and
human health.
  • Page 1 1
  • Page 2 2

Hager WBMSLL Operating instructions

Type
Operating instructions

Hager WBMSLL is an extension unit for master devices WBMDUR, WBMDUPB, and WBME5A. It is suitable for indoor use only and requires a neutral connection for LED indication. The device can be used to extend the range of the master device and is compatible with Hager Rotoloc switch plates. It has a momentary-contact current of >10 mA and requires a miniature circuit breaker of max. 10 A for protection.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI