< 2. Specications >
2-5
IM 12F5A1-01E
2.3.2 SamplingSystem
Model SuxCode Option Code Description
ST401G ..................... ................... Sampling system
System (note 3) -FC4
-PH5
-PF5
...................
...................
...................
With free available chlorine analyzer (FC400G) (note 1)
WithpHconverter(PH450G)(note2)
Withfreeavailablechlorineanalyzer(FC400G)andpH
converter(PH450G)(note1)(note2)(note3)
Ultrasonic oscillator
(forpHmeter)
-N
-U
...................
...................
Not supplied
Supplied
___
-A ................... Always -A
Option /R
/AN
/S
/ARS
/AZC1
/AZC2
/AZC3
/AZC4
/RR
/SCT
/TT3
Piping connections on the back
Without instrument
With stainless steel stand (note 4)
With arrester (power and signal lines only) (note 5)
Withautozerocalibrationfor100VAC(note6)
Withautozerocalibrationfor110VAC(note6)
Withautozerocalibrationfor200VAC(note6)
Withautozerocalibrationfor220VAC(note6)
With remote range switching (note 7)
With stainless tag plate
With500mlKClreservetankforpHsensor(note2)
Model ST401G refers only to a sampling system and does not include a free available chlorine
analyzerand/orapHmeter(sensor,holder,converterandultrasonicoscillator).(Instrumentshouldbe
purchased separately.)
Note that the ST401G Sampling System accepts the following models of note 1 or note 2 only, and
dependingonsystemconguration.
Note 1: Non-reagent type free available chlorine analyzer (refer to GS 12F5A1-E)
Whenordering,optioncode“/ST”(integrationintoST401Gsamplingsystem)mustbespecied.
Note2: 4-wiretypepHconvertersystem(refertoGS12B7C1-E,GS12B07C05-01E,GS12B07B02-E,GS12J05C02-00E)
pHsensor: PH8EFP-03-TN-TT1-N-T*A(whensuxcodeof“-PH4”,“-PF4”specied.)
PH8EFP-03-TN-TT3-N-T*A(whensuxcodeof“-PH4”,“-PF4”andoptioncodeof“/TT3”specied.)
PH8EFP-03-TN-TT1-N-G*A(whensuxcodeof“-PH5”,“-PF5”specied.)
PH8EFP-03-TN-TT3-N-G*A(whensuxcodeof“-PH5”,“-PF5”andoptioncodeof“/TT3”specied)
pHholders: PH8HF-PP-JPT-T-NN-NN*A(withoutcleaningsystem)
PH8HF-S3-JPT-T-NN-NN*A(withoutcleaningsystem)
PH8HF-PP-JPT-T-S3-C1*A(withultrasoniccleaning)
PH8HF-S3-JPT-T-S3-C1*A(withultrasoniccleaning)
pHconverter: PH400G-¨-EA*B(whensuxcodeof“-PH4”,“-PF4”specied.)
PH450G-A-E(whensuxcodeof“-PH5”,“-PF5”specied.)
Ultrasonic oscillator: PUS400G-NN-NN-¨-E(whichpowersupplyratingshouldbesameasthepHconverter.)
Note3: Powersupplyratingofnon-reagenttypefreeavailablechlorineanalyzershouldbesameasthepHconverter.
Note 4: Specify if needed, instead of the standard stanchion made of carbon steel.
Note5: Availableonlywhenthesuxcode“-FC4”,“-PH4”or“-PH5”isspecied.
Note6: AvailablewhenfreeavailablechlorineanalyzerisspeciedsinglyorincombinationwithpHmeter,bysuxcode,“-FC4”,
“-PF4” or “-PF5.”
Note7: Availablewhenfreeavailablechlorineanalyzerisspeciedsinglybysuxcode,“-FC4.”Anarresterissuppliedautomatically
with this option.