Eaton Sure-Lites LPX Series Installation guide

Type
Installation guide

Eaton Sure-Lites LPX Series is a combination exit and emergency light with self-diagnostic capabilities. It is designed to provide reliable and efficient emergency lighting in the event of a power outage. The LPX Series is also equipped with a variety of features that make it easy to use and maintain.

Some of the key features of the LPX Series include:

  • Self-diagnostic capabilities: The LPX Series continuously monitors its own performance and will signal any failures through a 3-color indicator LED. This makes it easy to identify and troubleshoot any problems with the unit.
  • 24-hour fast charge: The LPX Series can fully charge its battery in just 24 hours, which means it is always ready to provide emergency lighting when needed.

Eaton Sure-Lites LPX Series is a combination exit and emergency light with self-diagnostic capabilities. It is designed to provide reliable and efficient emergency lighting in the event of a power outage. The LPX Series is also equipped with a variety of features that make it easy to use and maintain.

Some of the key features of the LPX Series include:

  • Self-diagnostic capabilities: The LPX Series continuously monitors its own performance and will signal any failures through a 3-color indicator LED. This makes it easy to identify and troubleshoot any problems with the unit.
  • 24-hour fast charge: The LPX Series can fully charge its battery in just 24 hours, which means it is always ready to provide emergency lighting when needed.
INS #
Brand Logo
reversed out of
black
INS #
IB505051EN 049-304
Installation Instructions for the Sure-Lites LPX Combination Exit/Emergency Lights
and Exits with Self Diagnostics
WARNING
Risk of Fire/Electric Shock
If not qualified, consult an electrician.
WARNING
Risk of Electric Shock
Disconnect power at fuse or circuit breaker before
installing or servicing.
Important Safeguards
WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING
THE FOLLOWING.
1 READ AND FOLLOW ALL SAFETY INSTRUCTIONS
2 Do not use outdoors.
3 Do not use in hazardous locations, or near gas or electric
heaters.
4 Do not let power supply cords touch hot surfaces.
5 Do not use this equipment for other than the intended use.
6 Installation is to be performed only by qualified personnel.
7 Install in accordance with National Electric Code and local
regulatory agency requirements.
8 The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
9 Equipment should be mounted in locations and at heights
where it will not readily be subjected to tampering by
unauthorized personnel.
10 SAVE THESE INSTRUCTIONS
MAX MOUNTING HEIGHT:
17.24 FT
WALL MOUNT INSTALLATION
1 Extend unswitched 24 hour AC supply of rated voltage to
junction box (by others). Leave at least 18 inches of slack.
Circuit should not be energized at this time.
2 Remove the stencil face and lens assembly by applying a
screwdriver to the snaps located at the top and bottom of
the stencil face.
3 Knock out the appropriate mounting pattern and wire pass
hole to match junction box. Use the integrated wire hook
in the backplate to hold the wires in place so that there is
no shadowing on the face of the sign (see Figure 1).
4 Connect power supply and ground in accordance with
local codes. Wire connections as follows: 277VAC/240VAC
line to Orange lead or 120V line to Black lead; Neutral or
240V (Common) to white lead (see Schematic). Cap unused
line lead.
Note: Connections must be the enclosure rated area of the
frame (top left corner) or junction box (see Figure 1).
5 Mount to junction box.
6 Determine which color sign face is needed. If red is
needed, proceed to step 9
7 If green is the desired color, remove the red lens from
the stencil and replace it with the green lens provided.
(Installation is the reverse of removal.).
8 On the LED circuit board, locate the red/green jumper (See
Schematic).The jumper should be in the red position per
the silk screen printing on the board. Pull gently upward
on the jumper, then shift it one pin over to activate the
green LEDS.
9 If the unit has remote capacity, LED remotes can be
connected using the violet (+) and yellow (-) wires. (See
Schematic).
10 Energize AC supply, LED display will come on.
11 Replace the stencil cover assembly.
12 Remove EZ Key to connect battery. Battery will not charge
with EZ key in place. Allow 24 hours for charging with 120
or 277V input, 48 hours with 240V input.
2
EATON IB505051EN Installation instructions
Installation Instructions for LPX Combination Exit/Emergency Lights and Exits with Self
Diagnostics
CEILING OR END MOUNT INSTALLATION
1 Extend unswitched 24 hour AC supply of rated voltage to
junction box (by others). Leave at least 18 inches of slack.
Circuit should not be energized at this time.
2 Remove the stencil face and lens assembly by applying a
screwdriver to the snaps located at the top and bottom of
the stencil face.
3 If mounting the canopy to the top, remove the canopy hole
cover plate on the top. If locating the canopy on the side,
first remove the left side head by disconnecting the LED
lamp wires from the PCB (see Schematic) and gently pulling
on the head mount (see Figure 2). The head may now be
mounted in one of the 3 locations on the top (see Figure 2).
The center top mounting point can be accessed by removing
the cover. The left and right top mounting points can be
accessed by removing the small knock outs. The left side
head can also be moved to the top, to make the fixture
symmetric. Cover the unused holes with the canopy hole
cover plates.
4 If double face sign is required, convert the single face sign
supplied. Replace back plate with extra stencil and color
sheet supplied with the sign.
5 Place the canopy nose through the mounting hole until the
side of the frame touches the canopy. Lock the frame onto
the canopy by sliding the frame in a direction parallel to the
canopy length toward the narrow end of the mounting hole.
Slide the frame until both snaps engage the canopy nose
preventing any motion back out of the hole.
6 Mount mounting strap to junction box by choosing proper
slots and using screws supplied with junction box.
7 Feed the wires through the canopy.
Note: Connections must be the enclosure rated area of the
frame (top left corner) or junction box (see Figure 1).
8 Connect power supply and ground in accordance with
local codes. Wire connections as follows: 277VAC/240VAC
line to Orange lead or 120V line to Black lead; Neutral or
240V (Common) to white lead. Ground to Green screw on
mounting strap. Cap unused line lead.
9 Connect the canopy to the mounting strap using the screws
provided.
10 Determine which color sign face is needed. If red is needed,
proceed to step 13.
ENCLOSURE RATED AREA.
WIRE CONNECTIONS
SHOULD BE MADE HERE
OR IN JUNCTION BOX.
DO NOT MAKE WIRE
CONNECTIONS IN
SIGN FACE
INTEGRATED WIRE HOOK
JUNCTION
BOX
KNOCK
OUTS
TO JUNCTION BOX
CANOPY
HOLE PLUG
REMOVE KOS
TO MOUNT
HEAD
MOUNTING
STRAP
TO
JUNCTION
BOX
Figure 1
Figure 2
3
EATON IB505051EN Installation instructions
Installation Instructions for LPX Combination Exit/Emergency Lights and Exits with Self
Diagnostics
11 If green is the desired color, remove the red lens from
the stencil(s) and replace it with the green lens provided.
(Installation is the reverse of removal).
12 On the LED circuit board, locate the red/green jumper (See
Schematic).The jumper should be in the red position per the
silk screen printing on the board. Pull gently upward on the
jumper, then shift it one pin over to activate the green LEDS.
13 If the unit has remote capacity, LED remotes can be
connected using the violet (+) and yellow (-) wires. (See
Schematic).
14 Energize AC supply, LED display will come on.
15 Replace stencil, colored lens.
16 Remove EZ Key to connect battery. Battery will not charge
with EZ key in place. Allow 24 hours for charging with 120 or
277V input, 48 hours with 240V input.
ACTIVATING OPTIONAL FLASHER
If the consumer desires the exit sign to flash on and off when
in emergency mode, remove the jumper labeled FLASHER/J2
from the circuit board while unit is de-powered. See Schematic.
ACTIVATING TIME DELAY
The LPX Combo has an integrated time delay circuit that allows
the heads to remain in emergency mode 15 minutes after
power is restored. Remove the jumper on the circuit board
labeled TDI/J3 to activate the time delay.
MAINTENANCE
None required. Replace the batteries as needed according
to ambient conditions. However, we recommend that the
equipment be tested regularly in accordance with local codes.
NOTE: Servicing of any parts should be performed by qualified
personnel. Only use replacement parts supplied by Eaton’s
Lighting business.
CAUTION: This equipment is furnished with a sophisticated low
voltage battery dropout circuit to protect the battery from over
discharge after its useful output has been used. Allow 24 hours
recharge time if connected to 120 or 277V, 48 hours with 240V,
after installation or power failure for 90 minute testing.
TROUBLE SHOOTING GUIDE
If LED display or charge indicator LED does not illuminate,
check the following:
Check AC supply – verify that unit has 24 hour AC supply.
If LEDs do not light in emergency mode but Charge indicator
LED is on before test:
Unit is shorted or battery is not connected.
Battery discharged. Permit unit to charge for 24 hours (120
or 277V) or 48 hours (240V) and then re-test.
If following the above trouble shooting hints does not solve
your problem, contact your local Eaton Lighting representative
for assistance.
WARRANTIES AND LIMITATION OF LIABILITY
Please refer to www.eaton.com/LightingWarrantyTerms for our
terms and conditions.
WHITE LEAD - TO NEUTRAL OR 240V (COMMON)
ORANGE LEAD - TO 240 OR 277V
BLACK LEAD - TO 120V
ON BOARD
LED HEAD
ON BOARD
LED HEAD
BATTERY
2ND BATTERY
(HIGH POWER
MODELS ONLY)
REMOTE HEADS
(NOT INCLUDED)
POWER
SUPPLY PCB
REMOVE JUMPER TO
ACTIVATE TIME DELAY
SHIFT JUMPER TO
CHANGE LEDS FROM
RED TO GREEN
REMOVE
JUMPER TO
ACTIVATE
FLASHER
D4
F2
C1
F1
J1
C2
C3
+
MOV1
MOV2
Y
O
B
W
N
120
277
R
B
041-1418 REV B
-
+
041-1420 REV A
ICSP
GREEN
RED
+
-
+
FLASHER
POWER
BATT
J1
FAI
+
TDI
BATT
-
RMT
+
+
+
+
C 11
JP14
JP13
JP10
JP9
JP8
JP7
JP4
JP3
JP11
JP19
JP18
+
C1
CN7
LED6
LED5
LED8
LED7
LED9
LED10
LED4
LED3
LED2
LED1
J2
L1
CN4
C7
CN8
J3
JP2
JP17
JP15
CN6
CN5
CN3
JP6
JP12
C13
CN1
CN2
BW
JP1
Q14
JP5
Schematics
Eaton
1121 Highway 74 South
Peachtree City, GA 30269
P: 770-486-4800
www.eaton.com/lighting
© 2017 Eaton
All Rights Reserved
Printed in USA
Publication No. IB505051EN
August 3, 2017 12:18 PM
Eaton is a registered trademark.
All trademarks are property
of their respective owners.
Product availability, specifications,
and compliances are subject to
change without notice
USAGE INSTRUCTIONS FOR THE SURE-LITES EAGLE EYE
SELF DIAGNOSTICS
The Sure-Lites Eagle Eye Self Diagnostics is continuously
monitoring your emergency fixture, and will signal any failure
through the 3 color indicator LED.
Initial Operation
When the unit is first powered up, it will go into a 24 hour fast
charge, indicated by the indicator LED pulsing green. Once the
unit has fully charged, it will perform a self-calibration, after
which the LED will change to steady green, indicating the unit
is fully charged and float charging the battery to maintain
readiness.
Automatic Testing
The unit will perform a battery capacity, lamp/LED, and charge
circuit test every 30 days for 30 seconds. During this time, the
indicator LED will change to a steady yellow. It will perform a
full battery capacity (90 minute) test once per year. During this
time, the indicator LED will change to a blinking yellow.
Manual Testing
10 Second “Installation” test – Press and release the test
button once during fast charge (blinking green) to initiate
a 10 second quick test. The sign and LED lamps will switch
to emergency mode for 10 seconds allowing the installer to
verify proper installation of the unit, and the LED indicator
will turn solid yellow.
30 Second Test - Press and release the test button once
during float charge (steady green). The indicator LED will
turn steady yellow to indicate the unit is performing a 30
second test of the batteries and LED lamps.
90 Minute Test - Press and release the test button a second
time during a 30 second test (steady yellow) to change to
a 90 minute test. During this test, the LED indicator will
change to blinking yellow, and the circuit will perform a full
battery capacity, charge circuit, and LED test.
Canceling Test – Press and release the test button during the
90 minute test (flashing yellow) to return the fixture to its
original state (fast charge or float charge).
Clearing Failure Codes
A battery failure (LED two blink red) can be cleared by
replacing the battery. Disconnecting the battery and AC
power, or performing a full 90 minute discharge, will reset
the error code, however, it will return if the battery is faulty.
Charge Circuit (LED three blink red) and lamp/LED failure
(LED four blink red) will clear when the unit successfully
passes a manual or automatic 30 second test.
Indicators
LED Off - No power to unit, emergency mode.
LED Steady Green - Unit is fully charged and is float
charging the battery to maintain readiness.
LED Green Pulse - Unit is in a 24 hour fast charge of the
battery.
LED Two Blink Red - Battery has failed a capacity test, or
the battery is disconnected. See “Clearing Failure Codes”
above.
LED Three Blink Red - Battery charge circuit has failed. See
“Clearing Failure Codes” above.
LED Four Blink Red - Lamps have burned out, or 50% or
more of the sign LEDs have failed. See “Clearing Failure
Codes” above.
LED Steady Yellow - 30 second test or 10 second quick test
(Fast Charge only).
LED Blinking Yellow - 90 minute test.
SURE-LITES
STEADY BLINK
GREEN - FAST
CHARGE
STEADY YELLOW -
QUICK TEST
4 BLINK RED - LAMP /
LED FAILURE
3 BLINK RED - CHARGE
CIRCUIT FAILURE
STEADY BLINK YELLOW
- 90 MINUTE TEST
STEADY GREEN -
FULL / FLOAT
CHARGE
2 BLINK RED -
BATTERY FAILURE
OFF - EMERGENCY
MODE / POWER OFF
Eagle Eye
Self-Diagnostics
Installation Instructions for LPX Combination Exit/Emergency Lights and Exits with Self
Diagnostics
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Eaton Sure-Lites LPX Series Installation guide

Type
Installation guide

Eaton Sure-Lites LPX Series is a combination exit and emergency light with self-diagnostic capabilities. It is designed to provide reliable and efficient emergency lighting in the event of a power outage. The LPX Series is also equipped with a variety of features that make it easy to use and maintain.

Some of the key features of the LPX Series include:

  • Self-diagnostic capabilities: The LPX Series continuously monitors its own performance and will signal any failures through a 3-color indicator LED. This makes it easy to identify and troubleshoot any problems with the unit.
  • 24-hour fast charge: The LPX Series can fully charge its battery in just 24 hours, which means it is always ready to provide emergency lighting when needed.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI