Aktakom APS-7315 User manual

Type
User manual

This manual is also suitable for

www.tmatlantic.com
APS-7313/7315/7612
Table of Contents
SAFETY INSTRUCTION... .. .. .. ... .. .. .. .. .. .. .3
OVERVIEW... .. .. .. ... .. .. .. .. .. .. ... .. .. .. .. 5
Models Introduction. . . . . . . . . . . . ........ .5
Main Characteristics....................5
Front and Rear Panel Overview........ . . . . . . . . 6
OPERATION . .. .. .. .. .. .. ... .. .. .. .. .. .. .. .. .10
Power Up.. .. .. ... .. .. .. .. .. .. ... 10
Output ON/OFF. .. .. .. .. .. .. ... .. .. 11
Beep ON/OFF.. .. .. ... .. .. .. .. .. .. 11
Panel Lock. .. .. .. .. .. ... .. .. .. .. .11
Output Parameters Setup .. .. .. .. .. .. .12
Save Setup . .. ... .. .. .. .. .. .. ... .12
Recall Setup. . .. .. .. ... .. .. .. .. .. .13
1
Safety Symbols . .. .. .. .. .. .. ... .. .. 3
General Introduction.. .. .. ... .. .. .. .. 4
AC Input . .. .. .. .. .. ... .. .. .. .. .. .4
Fuse Parameters .. .. .. ... .. .. .. .. .. 4
FRONT PANEL INTRODUCTION... .. .. .. .. ... .. ..6
Panel Overview . .. .. .. .. .. ... .. .. .. 6
Display. .. .. ... .. .. .. .. .. .. ... .. .6
Status Indication . .. .. .. .. .. .. ... .. .6
Storage Indication .. ... .. .. .. .. .. .. .7
Brief Introduction of Panel Buttons . .. .. .. 7
REAR PANEL INTRODUCTION . ... .. .. .. .. .. .. ..9
KORAD
KA3000/6000-Series User Manual
KORAD
KA3000/6000-Series User Manual
REMOTE CONTROL.. .. .. ... .. .. .. .. .. .. ... 14
Remote Control Setup.. .. ... .. .. .. .1 4
Remote control procedures.... .. ... .1 5
FAQ .. . .. .. ... .. .. .. .. .. .. ... .. . ... ... .. ..16
SPECIFICATIONS . ... .. .. .. ... .. .. .. ... . ..17
2
APS-7313
APS-7315
APS-7612
KORAD
KA3000/6000-Series User Manual
KORAD
KA3000/6000-Series User Manual
7
C.CC.C
C.VC.V
OUTOUT
M2M2
M3M3
M4M4
M5M5
M1M1
Indication of saving an d recalling 5 setups stored internally;
OUT is output indicator. If light on, there is voltage
output in the output terminal.
C.C is con stan t current indicator. Whe n power
sup ply is in the mod e of constan t cur ren t,
thi s ligh t is on .
OCP is OCP indicator. When overcurrent function
is turned on, indicator lights on.
C.V is constant voltage indicator. When powe r supply
is in the mode of constant voltage, this light is on.
M3
M2
M1
M4
MEMOR Y
Saves or recalls panel settings. For settings,
1 ~ 4 are available. For save / recall details,
see Pa ge 13.
Storage Indication
Brief Introduction of Panel Operation
RECALL/SAVE
OCP
<
>
OVP
LO CK
UNLOCK
ADJUST
Volgote /
Current
Front panel lock_out function. For details, see Page 11.
Over-Current protect on/off,. Pressing this key for
more than 2 secends will make beep ON On/OFF.
Over-votage Protect On/Off
Output On/Off
Voltage-Current Setting Adjustment
Digit Selector Buttons
Selection Voltage / Current for Adjustment
Pressing the key, the volt indicator starts to
flicker; pressing it again, the ampere indicator
starts to flicker. Then turn the key ADJUST and
the settings of the setted voltage or current can
be adjusted.
POWER
On / Off main power. For power up sequence,
see Page 10.
+
-
Connects the ground (earth ) terminal.
outputs voltage and current.
BEEP
Off /ON
8
.
KORAD
KA3000/6000-Series User Manual
KORAD
KA3000/6000-Series User Manual
1 1
Output On / Off
Panel Operation Pressing the Output ke y to turn on output;
and the ke y LED also turns on. Pressing the
Output key again to turn off the output and
the key LED.
Note: If there are any of the following co nditions, the output will
automatica lly turn off.
1. OVP turns on and there are unusual OVP on the output terminal.
2. The se tting vo ltage is more than that of the OVP.
3. Recalling other se tups from the memory.
Beep On / Off
Panel Operation By default, the beep so und is enabled. To turn off
the beep, press the OCP(BEEP) key for 2 se conds.
A beep co mes out and the beep setting will be turned
off. To enable the beep, press the OCP(BEEP) ke y
again for 2 seconds.
Front Panel Lock
Panel operation
Press the LOCK key to lock the front panel key operation.
The key LED turns on. To unlock, press the LOCK key for
2 seconds.
1 2
Output Set
1. Connecti ng the load to the front port, CH 1 + / - .
2. Setting output voltage and cu rrent.
Press the key Voltage/Current selecti on to sw itch vo ltage adjustm ent
and cu rrent adjustm ent. Adjusti ng vo ltage and current with
Voltage / Current Adjustm ent knob. By default, the Voltage
and Current kn ob work in the co arse mode. To acti va te the
fine mode, press the ke ys to select the coarse mode or the
fine mode.
3. Turning on the output and press ing the output key.
The ke y LED turns on and disp lays CV or CC mode.
SAVE / RECALL SETUP
Save Setup
Back ground The front panel se ttings can be stored into one of
the four internal memories.
Contents The following list sh ows the se tup contents.
Fine / coarse kn ob editing mode
Beep on / off
Output voltage / current leve l
The following settings are always sa ve d as "off ".
Output on / off
Front panel lock on / off
Panel operation Press one of the 1 ~ 4 Memory ke ys for 2 se conds,
for example number 1. The panel se ttings are sa ve d
in memory No. 1 and the ke y LED turns on. When
the panel settings are modified, the LED turns off.
Panel operatio n
KORAD
KA3000/6000-Series User Manual
KORAD
KA3000/6000-Series User Manual
1 5
REMOTE CONTROL PROCEDURES
Entering the Remote Control Mode
1.Connecting USB
2.The power supply will automatically connect. After
normal connection, there will be a tweet from the
power supply itself.
3.The panel keys are locked, so the power supply can only
rely on the remote control.
Exiting from the Remote Control Mode
1.Closing the remote control software.
2. Disconnecting USB from the back.
3. The power supply disconnects; a tweet from the beep with
the hint that the remote control is over.
4. The power supply automatically comes into the panel
control mode.
1 6
Q1: The pane l but tons don' t wor k when pow er on.
Q2: Pressi ng ON/OFF, ther e is no out put when pow er on.
Q3: Output vol tage rises slowly when out put but ton is on.
A1: The pane l is locked. Pr es s the key for ov er 2 sec on ds, and then
the pa ne l will unlock.
A2: Cur ren t set up is 0.
A3: Cur ren t set up is too smal l.
Q4: Maki ng OCP on and pressi ng out put switch; and then the out put is
aut omatical ly shut off .
A4: Cur ren t protec tion val ue setup is too smal l. You could pres s ou tpu t
swi tch and then make OC P on.
LOCK
UNLOCK
FAQ
APS-7313 APS-7315 APS-7612
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Aktakom APS-7315 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI