1
4 Zones RF Clock
3
IMPORTANT!
Before starting work the installer should carefully read this Installation
& Operation Manual, and make sure all instructions contained therein
are understood and observed.
- The device should be mounted, operated and maintained by
specially trained personnel only. Personnel in the course of training
are only allowed to handle the product under the supervision of an
experienced fitter. Subject to observation of the above terms, the
manufacture shall assume the liability for the equipment as provided
by legal stipulations.
- All instructions in this Installation & Operation manual should be
observed when working with the controller. Any other application
shall not comply with the regulations. The manufacturer shall not be
liable in case of incompetent use of the control. Any modifications
and amendments are not allowed for safety reasons. The
maintenance may be performed by service shops approved by the
manufacturer only.
- The functionality of the controller depends on the model and
equipment. This installation leaflet is part of the product and has to
be obtained.
APPLICATION
- The RF clock is developed to control and manage by program
function the working mode of your panel heaters.
- The controllers have been designed for use in residential rooms,
office spaces and industrial facilities.
Verify that the installation complies with existing regulations before
operation to ensure proper use of the installation.
SAFETY INSTRUCTIONS
Before starting work disconnect power supply!
- All installation and wiring work related to the thermostat must be
carried out only when de-energized. The appliance should be
connected and commissioned by qualified personnel only. Make sure
to adhere to valid safety regulations.
- The thermostats are neither splash- nor drip-proof. Therefore, they
must be mounted at a dry place.
- Do not interchange the connections of the sensors and the 230V
connections under any circumstances! Interchanging these
connections may result in life endangering electrical hazards or the
destruction of the appliance and the connected sensors and other
appliances.
4
Table of content
1 Presentation.......................................................... 5
1.1 Keyboard .............................................................. 6
1.2 Display .................................................................. 7
2 First Installation .................................................... 8
2.1 Batteries installation ............................................. 8
2.2 Time and Date adjustment ................................... 8
2.3 RF installation ....................................................... 9
2.3.1 RF Installation with thermostat receiver ............... 9
2.3.2 RF Installation with Control conductor receiver . 11
2.3.3 RF installation check .......................................... 13
2.4 Starting ............................................................... 14
3 Working mode definition ..................................... 16
3.1 Manual mode Comfort ........................................ 16
3.2 Manual mode, Reduced ..................................... 16
3.3 OFF mode ........................................................... 16
3.4 Automatic mode .................................................. 17
3.5 Zone mode .......................................................... 17
3.6 Program Mode .................................................... 18
3.7 Holiday mode ...................................................... 22
3.8 Timer mode ......................................................... 23
4 Special function .................................................. 23
4.1 Keyboards lock Function .................................... 23
4.2 Optional Input ..................................................... 24
5 Parameter’s menu .............................................. 24
6 Technical characteristics .................................... 27
7 Troubleshooting & Solution ................................ 28
5
1 Presentation
4 zones digital clock with LCD display specially designed to
supervise the working mode of the electrical radiators
installation.
It will be your best partner to optimize your energy
consumption and increase your comfort.
- Wiring & easy Installation.
- “Easy program creation” function.
- Weekly programmable by step of 30min.
- Temporary override function.
- Anti freeze function.
- Holiday or Reception (Timer) function.
- EEPROM non volatile memory.
- 2 AA batteries for 2 years operating life.
- 1 parameter menu, (User and Installer)
*In option
1 input for GSM control (secondary house…)
In order to have the clock controlling your radiators, the
must be in Auto Mode and the Control conductor must not
be connected but isolated.
6
1.1 Keyboard
( ) Back key to return to the previous menu.
(►+) Navigation key “right” in menu selection or plus
key for value edition.
(-) Navigation key “left” in menu selection or minus
key for value edition.
(OK) Validation key.
Backlight function:
Short press on this key (OK) permit to light up the
backlight for 10 seconds.
(i) Main menu key.
7
1.2 Display
1. Operating mode menu (active mode is framed).
2. Key lock indicator
3. Installation Parameter menu.
4. Current day of the week (1 = Monday)
5. Current time or parameter title if is displayed.
6. Pictogram for program creation.
program state in normal operating mode.
7. Room Temperature indicator.
8. Room temperature if “ ” is displayed. Parameter
value if “ is displayed.
9. RF transmission logo.
10. Program of the current day
(the current time bar blinks)
11. Zone status (Comfort, Reduced or Temporary
override function).
12. “Low Batteries” indicator.
13. External option is activate.
1
2
3
4
5
6
7
11
10
13
8
9
12
8
2 First Installation
This section will guide you to set up your thermostat for the
first time.
2.1 Batteries installation
- Open the backside cover and insert the 2 AA Alkaline
supplied batteries (or remove the small protection sticker if
the batteries are already installed in the compartment)
- Close the cover.
- Now you are invited to adjust and configure the
necessaries parameters.
2.2 Time and Date adjustment
Each time a value blinks, you can adjust it with the (◄-)
and (►+) keys, once the value is chosen, validate it with
the (OK) key. The clock will jump automatically to the next
value.
you can always come back to the previous value by
pressing the escape key ( ).
List order of the time and date adjustments:
Time and day:
Adjustment of the hours,
Adjustment of the minutes
Adjustment of the day (1 = Monday)
Date:
Adjustment of the day number (0 to 31).
Adjustment of the month number (01 to 12).
Adjustment of the year (Century).
Adjustment of the year
Then the message Saveappear, press (OK) to valid your
adjustments.
You can always reach the time and date adjustments, by
pressing and maintaining the (OK) key during 2 seconds in
normal operating modes.
9
2.3 RF installation
2.3.1 RF Installation with thermostat receiver
a) Press on the (OK) key to enter in the “RF init” mode, you
can now choose the zone which needs to be configured
by moving the frame cursor (around number 1) with (◄-)
and (►+) keys on the desired zone number, 1 to 4.
b) Once the zone selected, press on the (OK) key and
choose if you want to use it with (◄-) and (►+) Yes” or
no,
- If you choose “no” the zone will be not displayed on the
main screen, then choose another one.
- If you choose “Yes” the following screen must be
displayed and the clock will start to send now the radio
configuration signal to the receiver.
10
c) On the receiver, press and maintain few seconds the
Button” until the green LED flashing. (you can now
release the button)
d) Now your receiver is linked and ready to work with
your clock.
- Once the configuration between the receiver and the
clock made, repeat this step (d) to link all the receivers
which need to works on the same zone.
- Repeat the step (b) to (d) if you need more zones on
your installation.
e) Go to the parameter End with the key (►+) and
press (OK) to exit the parameter menu.
11
2.3.2 RF Installation with Control conductor
receiver
a) First of all you must put all Control conductor receivers
which need to works on the same zone in “RF init
mode.
For this, press the Receiver push button during 5sec, the
Green RF LED should lit up (fixed) indicating that the
Receiver is now in radio configuration mode waiting for a
clock configuration address.
b) Now on the clock, you must enter in the installer menu
by pressing the ( ) key during 8s, then the following
screen must be display.
5s
12
c) Then, press on the (OK) key to enter in the “RF init
mode, you can now choose the zone which need to be
configured by moving the frame cursor with (◄-) and
(►+) keys on the desired zone number (1 to 4).
d) Once the zone selected, press on the (OK) key and
choose if you want to use it “Yes” or “no”,
- If you choose “no” the zone will be not displayed on the
main screen, then choose another one.
- If you choose “Yes” the following screen must be
displayed and the clock will start to send now the radio
configuration signal to the receiver.
e) On the receivers, check the good reception of the
signal, generally showed by a green blinking RF LED.
13
Now your receiver is linked and ready to work with your
clock.
- Repeat the step (b) to (d) if you need more zones on your
installation.
f) Go to the parameter End with the key (►+) and
press (OK) to exit the parameter menu.
2.3.3 RF installation check
Now you can exit the installer menu on your clock and
come back to the main screen. To do this, go to the
parameter “Endwith the key (►+) and press (OK).
Checking rules for Thermostat receiver
To check your installation, you can perform a RF distance
test.
- First of all, from the main screen press on the menu key
(i) and choose the Comfort menu
with (◄-) and (►+).
- Now, put all your receivers in AUTO mode (green fixed
LED or red fixed if the thermostat receiver is in heating
demand).
- Then on the RF clock, from the main screen press on the
menu key (i) and choose the reduced menu
with (◄-)
and (►+).
- Now go to the rooms (zones) which must be controlled by
the clock and check all receivers to be sure that the new
working mode has received (Reduced mode, green LED
blinking or alternate red/green blinking if heating demand).
Now your installation is checked and ready to works.
14
Checking rules for Control Conductor Receiver
- First of all, from the main screen press on the menu key
(i) and choose the Comfort menu
with (◄-) and (►+).
- Now, put all your radiators in AUTO mode and check the
LED of your control conductor receiver (green fixed LED to
indicate Comfort)
- Then on the clock, from the main screen press on the
menu key (i) and choose the reduced menu
with (◄-)
and (►+).
- Now go to the rooms (zones) which must be controlled by
the clock and check all control conductor receivers to be
sure that the new working mode has received (Reduced
mode, green LED blinking).
Now your installation is checked and ready to works.
To make the installation easier it will be better to have the
clock near to the receiver during the configuration mode.
(A minimal distance of > 50cm must be respected to avoid
bad RF reception)
2.4 Starting
The clock is now ready to works.
The default working mode will be automatic
with a
standard built-in program “P1 for all the zones.
Monday to Friday
20°C
18°C
07:00 09:00 17:00 23:00
15
Saturday & Sunday
20°C
18°C
08:00 23:00
Note:
You can customise your program as you want, See the
next part “Working mode definition” chapter “Zone
Program” for more explanation.
At any time, when the backlight is extinct, press the (OK)
key to lit-up the backlight,
and then press another time the (OK) key to show another
zone.
Curent
stage of the
program
Curent time
Program
followed
by Zone1
Viewed zone
16
3 Working mode definition
How to change the working mode?
- Press on the menu key (i) to show the working mode line.
- You can now press the keys (◄-) and (►+) to
move the frame cursor on the desired working mode and
press (OK) to valid you choice.
3.1 Manual mode Comfort
Manual working mode, all zones will follow the Comfort
operating mode all the time.
3.2 Manual mode, Reduced
Manual working mode, all zones will follow the Reduced
operating mode all the time.
3.3 OFF mode
Use this mode if you need to switch off your installation.
Be Careful:
- In this mode your installation can freeze.
- The radiators are live, as they still are connected to the
electric network.
- At any time, when display is off, press on the (Ok) key to
display a few seconds the current temperature and time.
- To restart your installation, use the navigation keys (◄-)
and (►+).
17
3.4 Automatic mode
In this mode all zones will follow the chosen program (Built-
in or customized) according to the actual time.
You can easily override, until next program step, the
current program mode. By pressing the (◄-) or (►+) keys
move the frame cursor on the desired zone, then press
(OK) and choose the override function with (►+).
The small hand logo will be displayed when override
function is active.
The override will leave automatically when the program
changes to “ ” or “ ” the next time. To stop the override
manually, press (i) and (OK).
3.5 Zone mode
Press (i) and (◄-) or (►+) to reach the Zone mode.
When you enter in the Zone mode, the first operation is to
choose the zone number with (◄-) or (►+) keys.
Then press (OK) to choose now with (◄-) or (►+) the
program number. You have the choice between a built-in
program P1 to P9 and a user program U1 to U4.
If you chose a Built-in program P1 to P9,
(See the Annexe parts to view a complete description of
the Built-in program)
- Use the menu key (i) to change the program day
displayed.
- Press the (OK) key to confirm your choice and come back
to the main screen (in AUTO mode)
Current
day
Program
of the day
Zone
displayed
Program
followed
by the
displayed
zone
18
If you chose a user program U1 to U4,
As above you can choose the program, see it,
but you can also customise it in the Program Mode .
3.6 Program Mode
Press (i) and (◄-) or (►+) to reach the Program mode.
Use this mode to customise the User programs U1 to U4.
Default setting:
U1, U2, U3, U4 = Comfort all the week
Symbols and explanation for program creation:
First step of the day ( Comfort temp.)
The wakeup hour need to be adjusted.
Middle step of the day ( Reduced temp.)
The leaving hour need to be adjusted
Middle step of the day ( Comfort temp.)
The comeback hour will need to be adjusted
Last step of the day ( Reduced temp.)
The sleeping hour need to be adjusted
- The program step is 30 minutes
- Each time a value or icon blinks you are invited to make a
choice with (◄-) or (►+) keys,
once the choice is made press the (OK) key to jump to the
following step.
- The program creation will always start with the day 1
(Monday).
Once you have pressed the (OK) key, the following display
will appear:
19
Now you are invited to adjust the hour of the first step of
the program with (◄-) or (►+),
Press (OK) to validate and go to the following step.
Now you are invited to choose the type of the next step of
the program (blinking icons),
2 choices will be possible:
- 1
st
choice is to choose the sleep icon. (End of the day)
- 2
nd
choice is to choose the leaving icon, to add one step
to the program during the day.
When the choice is made, press (OK) to validate.
Then you can adjust the step hour with (◄-) or (►+),
20
When step hour is set press (OK) to jump to the next step.
You will be directly invited to adjust with (◄-) or (►+) the
hour of the comeback step.
Press (OK) to validate and go to the following step.
You are again invited to choose the type of the next step of
the program (blinking icons),
2 choices will be possible:
- 1
st
choice is to choose the sleep icons. (End of the day)
21
- 2
nd
choice is to choose the leaving icons, to add another
step to the program during the day.
When the choice is made, press (OK) to valid and you can
adjust the hour of this step with (◄-) or (►+),
Press (OK) to validate and finish the edition of the first day.
Now you can choose to copy the program day just created
to subsequent days.
Change the choice “Yes” or “no” with (◄-) or (►+) and
validate your choice with (OK).
- If you select “no”, you will be invited to create a program
for Tuesday (repeat the previous method to built it.)
- If you select “Yes”, you will have the possibility to copy
the program to the following day (on Tuesday on
Wednesday... up to the last day of the week
(7 Sunday).
When you press (OK) on the last day (7 Sunday) you will
be invited to “SAVE” your program.
Then the message Save” and blinking green LED
appears:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

RADSON 4 Zones RF Clock Operating instructions

Category
Thermostats
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI