H3C S3100 Series Installation guide

Type
Installation guide
H3C S3100 Series Ethernet Switches
Installation Manual
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: 20090601-C-1.06
Copyright © 2007-2009, Hangzhou H3C Technologies Co., Ltd. and its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form or by any means without prior
written consent of Hangzhou H3C Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H
3
Care,
, TOP G, , IRF, NetPilot, Neocean, NeoVTL,
SecPro, SecPoint, SecEngine, SecPath, Comware, Secware, Storware, NQA, VVG, V
2
G, V
n
G, PSPT,
XGbus, N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co.,
Ltd.
All other trademarks that may be mentioned in this manual are the property of their respective owners.
Notice
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of any kind, express or implied.
Technical Support
customer_service@h3c.com
http://www.h3c.com
About This Manual
Organization
H3C S3100 Series Ethernet Switches Installation Manual is organized as follows:
Chapter Contents
1 Product Introduction
Introduces the characteristics and technical specifications of
S3100 Series Ethernet Switches.
2 Installation Preparation
Introduces the installation preparation and precaution of
S3100 Series Ethernet Switches.
3 Installation
Introduces the procedures to install an S3100 Series
Ethernet Switch, including the setup of the mainframe, cards
and cables.
4 First Power-on
Introduces the booting process of an S3100 Series Ethernet
Switch, including the power-on booting of the switch and the
system initialization.
5 Boot ROM and Host Software
Loading
Introduces how to load Boot ROM and host software for an
S3100 Series Ethernet Switch.
6 Maintenance and Troubleshooting
Introduces the problems that might occur during the
installation and the booting of an S3100 Series Ethernet
Switch and the related solution.
7 Appendix Lightning Protection of
the Switch
Introduces lightning protection of S3100 Series Ethernet
Switches.
Conventions
The manual uses the following conventions:
Command conventions
Convention Description
Boldface
The keywords of a command line are in Boldface.
italic
Command arguments are in italic.
[ ] Items (keywords or arguments) in square brackets [ ] are optional.
{ x | y | ... }
Alternative items are grouped in braces and separated by vertical bars.
One is selected.
[ x | y | ... ]
Optional alternative items are grouped in square brackets and
separated by vertical bars. One or none is selected.
{ x | y | ... } *
Alternative items are grouped in braces and separated by vertical bars.
A minimum of one or a maximum of all can be selected.
[ x | y | ... ] *
Optional alternative items are grouped in square brackets and
separated by vertical bars. Many or none can be selected.
&<1-n>
The argument(s) before the ampersand (&) sign can be entered 1 to n
times.
# A line starting with the # sign is comments.
GUI conventions
Convention Description
< > Button names are inside angle brackets. For example, click <OK>.
[ ]
Window names, menu items, data table and field names are inside
square brackets. For example, pop up the [New User] window.
/
Multi-level menus are separated by forward slashes. For example,
[File/Create/Folder].
Symbols
Convention Description
Means reader be extremely careful. Improper operation may cause
bodily injury.
Means reader be careful. Improper operation may cause data loss or
damage to equipment.
Means an action or information that needs special attention to ensure
successful configuration or good performance.
Means a complementary description.
Means techniques helpful for you to make configuration with ease.
Related Documentation
In addition to this manual, each H3C S3100 Series Ethernet Switches documentation set includes the
following:
Manual Description
H3C S3100 Series Ethernet Switches
Operation Manual
It is used for assisting the users in data configurations
and typical applications.
H3C S3100 Series Ethernet Switches
Command Manual
It is used for assisting the users in using various
commands.
Obtaining Documentation
You can access the most up-to-date H3C product documentation on the World Wide Web at this URL:
http://www.h3c.com.
The following are the columns from which you can obtain different categories of product documentation:
[Products & Solutions]: Provides information about products and technologies.
[Technical Support & Document > Technical Documents]: Provides several categories of product
documentation, such as installation, configuration, and maintenance.
[Technical Support & Document > Software Download]: Provides the documentation released with the
software version.
Documentation Feedback
You can e-mail your comments about product documentation to [email protected].
We appreciate your comments.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the
proper storage, use and disposal of this product, national laws and regulations must be observed.
i
Table of Contents
1 Product Introduction·································································································································1-1
Overview ·················································································································································1-1
S3100-SI Series Ethernet Switches ································································································1-1
S3100-EI Series Ethernet Switches ································································································1-4
Introduction to S3100-SI Series Ethernet Switches················································································1-7
S3100-52TP-SI································································································································1-7
S3100-26TP-SI································································································································1-8
S3100-16TP-SI································································································································1-9
S3100-8TP-SI································································································································1-11
S3100-26T-SI ································································································································1-12
S3100-16T-SI ································································································································1-13
S3100-8T-SI ··································································································································1-14
S3100-26C-SI································································································································1-15
S3100-16C-SI································································································································1-16
S3100-8C-SI··································································································································1-17
Introduction to S3100-EI Series Ethernet Switches··············································································1-19
S3100-26TP-EI······························································································································1-19
S3100-16TP-EI······························································································································1-20
S3100-8TP-EI································································································································1-22
S3100-26TP-PWR-EI ····················································································································1-23
S3100-16TP-PWR-EI ····················································································································1-25
S3100-8TP-PWR-EI ······················································································································1-27
S3100-26C-EPON-EI ····················································································································1-28
S3100-16C-EPON-EI ····················································································································1-29
S3100-8C-EPON-EI ······················································································································1-30
Introduction to Front Panel LEDs··········································································································1-31
Front Panel LEDs of the S3100-T-SI/S3100-C-SI/S3100-TP-PWR-EI/ S3100-C-EPON-EI Series
·······················································································································································
1-31
Front Panel LEDs of the S3100-TP-SI and S3100-TP-EI Series··················································1-32
SFP Modules Supported by S3100 Ethernet Switches ········································································1-34
ONU Modules········································································································································1-34
2 Installation Preparation·····························································································································2-1
Precautions ·············································································································································2-1
Requirements on Environment ···············································································································2-1
Temperature/Humidity Requirements ·····························································································2-1
Cleanness Requirements ················································································································2-2
Anti-interference Requirements·······································································································2-2
Laser Usage Security ······················································································································2-3
Installation Tools ·····································································································································2-3
3 Installation··················································································································································3-1
Installing a Switch ···································································································································3-1
Cabinet Mounting ····························································································································3-1
Desk Mounting·······························································································································3-10
ii
Wall Mounting································································································································3-10
Magnet Mounting···························································································································3-12
Connecting Grounding Cable················································································································3-14
When a Grounding Strip is Available·····························································································3-14
Where a Grounding Conductor Can be Buried ·············································································3-16
In Other Installation Sites ··············································································································3-16
Connection of Power Cable ··················································································································3-18
Connecting AC Power Cable·········································································································3-18
Connecting DC Power Cable ········································································································3-19
Installing an Expansion Interface Module ·····························································································3-21
Connecting Optical Fiber ······················································································································3-22
Installation Verification ··························································································································3-23
4 First Power-on············································································································································4-1
Establishing Configuration Environment ·································································································4-1
Connecting the Console Cable ···············································································································4-1
Console Cable ·································································································································4-1
Connection Procedure·····················································································································4-2
Setting Terminal Parameters ··················································································································4-2
Booting Switch ········································································································································4-5
Checking Before Powering on the Switch ·······················································································4-5
Powering on the Switch···················································································································4-5
Changing the Startup Mode ············································································································4-6
5 Boot ROM and Host Software Loading ···································································································5-1
Introduction to Loading Approaches ·······································································································5-1
Local Software Loading ··························································································································5-1
Boot Menu ·······································································································································5-2
Loading Software Using XModem Through Console Port ······························································5-3
Loading Software Using TFTP Through Ethernet Port ···································································5-7
Loading Software Using FTP Through Ethernet Port······································································5-8
Remote Software Loading ····················································································································5-10
Remote Loading Using FTP ··········································································································5-10
Remote Loading Using TFTP········································································································5-11
6 Maintenance and Troubleshooting··········································································································6-1
Software Loading Failure ························································································································6-1
Missing Password ···································································································································6-1
Missing user password ····················································································································6-1
Missing Boot ROM Password··········································································································6-2
Power System Failure ·····························································································································6-2
Configuration System Failure··················································································································6-2
1-1
1 Product Introduction
Overview
The H3C S3100 Series Ethernet Switches are high-performance, high-density, easy-to-install,
NMS-manageable intelligent Ethernet switches which support wire-speed Layer 2 switching.
Table 1-1 Models of the H3C S3100 Series Ethernet Switches
Name Subseries Model
S3100-TP-SI
z S3100-8TP-SI
z S3100-16TP-SI
z S3100-26TP-SI
z S3100-52TP-SI
S3100-T-SI
z S3100-8T-SI
z S3100-16T-SI
z S3100-26T-SI
S3100-SI
S3100-C-SI
z S3100-8C-SI
z S3100-16C-SI
z S3100-26C-SI
S3100-TP-EI
z S3100-8TP-EI
z S3100-16TP-EI
z S3100-26TP-EI
S3100-TP-PWR-EI
z S3100-8TP-PWR-EI
z S3100-16TP-PWR-EI
z S3100-26TP-PWR-EI
H3C S3100
Series Ethernet
Switches
S3100-EI
S3100-C-EPON-EI
z S3100-8C-EPON-EI
z S3100-16C-EPON-EI
z S3100-26C-EPON-EI
S3100-SI Series Ethernet Switches
S3100-TP-SI Series
Table 1-2 Technical specifications for S3100-TP-SI Series Ethernet switches
Model S3100-52TP- SI S3100-26TP- SI S3100-16TP-SI S3100-8TP-SI
Physical
dimensions (H x
W x D)
43.6 × 440 × 230
mm (1.7 × 17.3 ×
9.1 in.)
43.6 × 440 × 160
mm (1.7 × 17.3 ×
6.3 in.)
43.6 × 360 × 160
mm (1.7 × 14.2 ×
6.3 in.)
43.6 × 230 × 160
mm (1.7 × 9.1 ×
6.3 in.)
Weight <4.5kg (9.9 lb.) 3 kg (6.6 lb.)
1-2
Model S3100-52TP- SI S3100-26TP- SI S3100-16TP-SI S3100-8TP-SI
24 × auto-sensing
10/100Base-TX
Ethernet port
2 × 1000 Mbps
Combo port
16 x auto-sensing
10/100Base-TX
Ethernet port
2 x 1000Mbps
Combo port
8 × auto-sensing
10/100Base-TX
Ethernet port
1 × 1000 Mbps
Combo port
Number of fixed
ports
48 x auto-sensing
10/100Base-TX
Ethernet port
2 x auto-sensing
10/100/1000Base
-T Ethernet port
2 x
100/1000Base-X
SFP port
Note: A 100/1000Base-X SFP port and a corresponding
auto-sensing 10/100/1000Base-T Ethernet port form a
Combo port. For each Combo port, either the SFP port or
the corresponding 10/100/1000Base-T Ethernet port can
be used at a time.
Number of
management
port
1 x console port
Power system
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz /60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63Hz
PoE (as powered
device)
Not supported Not supported Not supported Not supported
System power
consumption (full
load)
24 W 16 W 14 W 10W
Fan None None None None
Operating
temperature
0°C to 45°C (30°F to 113°F)
Relative humidity
(non-
condensing)
10% to 90%
S3100-T-SI Series
Table 1-3 Technical specifications for the S3100-T-SI series
Item S3100-26T-SI S3100-16T-SI S3100-8T-SI
Physical dimensions
(H × W × D)
42 × 436 × 240 mm
(1.65 × 17.2 × 9.4 in.)
42 × 436 × 200 mm
(1.65 × 17.2 × 7.9 in.)
42 × 326 × 200 mm
(1.65 × 12.8 × 7.9 in.)
Weight 3.2 kg (7.1 lb.)
Number of fixed ports
24 × auto-sensing
10/100Base-TX
Ethernet port
2 ×
10/100/1000Base-T
Ethernet port
16 × auto-sensing
10/100Base-TX
Ethernet port
1 ×
10/100/1000Base-T
Ethernet port
8 × auto-sensing
10/100Base-TX
Ethernet port
1 ×
10/100/1000Base-T
Ethernet port
Number of
management ports
1 × console port
Power system
Only AC input is supported.
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1-3
Item S3100-26T-SI S3100-16T-SI S3100-8T-SI
PoE (as powered
device)
Not supported Not supported Not supported
System power
consumption (full load)
20 W 12 W 10 W
Fan None None None
Operating temperature 0°C to 45°C (30°F to 113°F)
Relative humidity
(noncondensing)
10% to 90%
S3100-C-SI Series
Table 1-4 Technical specifications for the S3100-C-SI series
Item S3100-26C-SI S3100-16C-SI S3100-8C-SI
Physical dimensions
(H × W × D)
42 × 436 × 240 mm
(1.65 × 17.2 × 9.4 in.)
42 × 436 × 200 mm
(1.65 × 17.2 × 7.9 in.)
42 × 326 × 200 mm
(165 × 12.8 × 7.9 in.)
Weight 3.2 kg (7.1 lb.)
Number of fixed ports
24 × auto-sensing
10/100Base-TX
Ethernet port
16 × auto-sensing
10/100Base-TX
Ethernet port
8 × auto-sensing
10/100Base-TX
Ethernet port
Number of expansion
slots
2 2 1
Number of
management ports
1 × console port
Supported expansion
interface module type
10/100/1000Base- T interface module with max transmission distance of
100 m (328.1 feet)
100Base- SX (SC, 2 km (1.2 mi))
100Base- LX (SC, 15 km (9.3 mi))
100Base- LH40 (SC, 40 km (24.9 mi))
1000Base- SX (SC, 0.5 km (0.3 mi))
1000Base- LX (SC, 10 km (6.2 mi))
1000Base- LH40 (LC, 40 km (24.9 mi))
1000Base- LH70 (LC, 70 km (43.5 mi))
1000Base- STACK (not supported by S3100-8C-SI)
100Base- TX PD (powered device) interface module (only supported by
S3100-16C-SI DC-powered switch and S3100-8C-SI DC-powered switch)
1000Base- PX10 (SC, 10 km (6.2 mi))
1000Base- PX20 (SC, 20 km (12.4 mi))
100Base-LX-SM1310-BIDI (SC, 15 km (9.3 mi))
100Base-LX-SM1550-BIDI (SC, 15 km (9.3 mi))
1-4
Item S3100-26C-SI S3100-16C-SI S3100-8C-SI
Power system
Both DC-powered switch and AC-powered switch are available to each
model. The AC-powered switch supports only AC input, and the
DC-powered switch supports only DC input.
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
DC input:
z Rated voltage range: –48 VDC to –60 VDC
z Input voltage range: –36 VDC to –72 VDC
PoE (as powered
device)
Not supported
Supported by
DC-powered switch
Supported by
DC-powered switch
System power
consumption (full load)
20 W 12 W 10 W
Fan None None None
Operating temperature 0°C to 45°C (30°F to 113°F)
Relative humidity
(noncondensing)
10% to 90%
z Only S3100-16C-SI DC-powered switch or S3100-8C-SI DC-powered switch supports 100Base-
TX PD interface module. Notice that S3100-16C-SI DC-powered switch can accommodate only
one PD interface module.
z The PoE configuration is on the remote power source device, on the powered device
(S3100-16C-SI DC-powered switch or S3100-8C-SI DC-powered switch), you only need to insert
the cable into the interface of 100Base- TX PD.
z BIDI interface card must be used in couple; that is, if the local end uses 100Base-LX-SM1310-BIDI,
the remote end needs to use 100Base-LX-SM1550-BIDI.
z An S3100-16C-SI or S3100-26C-SI switch can accommodate only one ONU module
(1000Base-PX10/20). For details about ONU modules, refer to section “
ONU Modules”.
S3100-EI Series Ethernet Switches
S3100-TP-EI Series
Table 1-5 Technical specifications for the S3100-TP-EI series
Item S3100-26TP-EI S3100-16TP-EI S3100-8TP-EI
Physical dimensions
(H × W × D)
43.6 × 440 × 160 mm
(1.7 × 17.3 × 6.3 in.)
43.6 × 360 × 160 mm
(1.7 × 14.2 × 6.3 in.)
43.6 × 230 × 160 mm
(1.7 × 9.1 × 6.3 in.)
Weight 3 kg (6.6 lb.)
1-5
Item S3100-26TP-EI S3100-16TP-EI S3100-8TP-EI
24 × auto-sensing
10/100Base-TX
Ethernet port
2 × 1000 Mbps Combo
port
16 × auto-sensing
10/100Base-TX
Ethernet port
2 × 1000 Mbps Combo
port
8 × auto-sensing
10/100Base-TX
Ethernet port
1 × 1000 Mbps Combo
port
Number of fixed ports
Note: A 100/1000Base-X SFP port and a corresponding auto-sensing
10/100/1000Base-T Ethernet port form a Combo port. For each Combo
port, either the SFP port or the corresponding 10/100/1000Base-T
Ethernet port can be used at a time.
Number of
management ports
1 × console port
Power system
Both DC-powered switch and AC-powered switch are available to each
model. The AC-powered switch supports only AC input, and the
DC-powered switch supports only DC input.
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
DC input:
z Rated voltage range: –48 VDC to –60 VDC
z Input voltage range: –36 VDC to –72 VDC
PoE (as powered
device)
Not supported Not supported Not supported
System power
consumption (full load)
17W 15W 12W
Fan None None None
Operating temperature 0°C to 45°C (30°F to 113°F)
Relative humidity
(noncondensing)
10% to 90%
S3100-TP-PWR-EI Series
Table 1-6 Technical specifications for the S3100-TP-PWR-EI series
Item S3100-26TP-PWR-EI S3100-16TP-PWR-EI S3100-8TP-PWR-EI
Physical dimensions
(H × W × D)
43.6 × 440 × 420 mm
(1.7 × 17.2 × 10.2 in.)
43.6 × 300 × 260 mm
(11.8 × 8.7 × 1.7 in.)
43.6 × 300 × 220 mm
(1.7 × 9.1 × 7.9 in.)
Weight < 6.5 kg (14.3 lb.) < 3.5 kg (7.7 lb.) < 3.0 kg (6.6 lb.)
24 × auto-sensing
10/100Base- TX
Ethernet port
2 × 1000 Mbps Combo
port
16 × auto-sensing
10/100Base- TX
Ethernet port
2 × 1000 Mbps Combo
port
8 × auto-sensing
10/100Base- TX
Ethernet port
1 × 1000 Mbps
Combo port
Number of fixed ports
Note: A 100/1000Base-X SFP port and a corresponding auto-sensing
10/100/1000Base-T Ethernet port form a Combo port. For each Combo
port, either the SFP port or the corresponding 10/100/1000Base-T
Ethernet port can be used at a time.
Number of
management ports
1 × console port
1-6
Item S3100-26TP-PWR-EI S3100-16TP-PWR-EI S3100-8TP-PWR-EI
Power system
S3100-26TP-PWR-EI Ethernet switches support AC input and DC input.
S3100-16TP-PWR-EI/S3100-8TP-PWR-EI Ethernet switches support
only AC input.
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
DC input:
z Rated voltage range: –52 VDC to –56 VDC
System
power
consumption
(full load)
AC input: 465 W
DC input: 400 W
160 W 95 W
All ports
serve as
PoE
ports
PoE power
maximum
15.4 W × 24 15.4 W × 8 15.4 W × 4
Number of fans 4 2 2
Operating temperature 0°C to 45°C (30°F to 113°F)
Relative humidity
(noncondensing)
10% to 90%
S3100-26TP-PWR-EI, S3100-16TP-PWR-EI, and S3100-8TP-PWR-EI Ethernet switches provide an
over-temperature protection mechanism. When the internal temperature exceeds 65°C (149°F), they
will stop providing power from all ports. When the temperature is below 60°C (140°F), they will continue
to provide power from all ports.
S3100-C-EPON-EI Series
Table 1-7 Technical specifications for the S3100-C-EPON-EI series
Item S3100-26C-EPON-EI S3100-16C-EPON-EI S3100-8C-EPON-EI
Physical
dimensions (H × W
× D)
42 × 436 × 240 mm
(1.65 × 17.17 × 9.45 in.)
42 × 436 × 200 mm
(1.65 × 17.17 × 7.87 in.)
42 × 326 × 200 mm
(1.65 × 12.83 × 7.87 in.)
Weight 3.2 kg (7.05 lb.) 3.2 kg (7.05 lb.) 3.2 kg (7.05 lb.)
Number of fixed
ports
24 × 10/100Base-TX
ports
1 × 1000 Mbps PON
port
16 × 10/100Base-TX
ports
1 × 1000 Mbps PON
port
8 × 10/100Base-TX
ports
1 × 1000 Mbps PON
port
Number of
expansion slots
1 Disabled
Optional module
ONU module
(1000Base-PX20)
— —
Number of
management ports
1 console port
1-7
Item S3100-26C-EPON-EI S3100-16C-EPON-EI S3100-8C-EPON-EI
Power system
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
PoE (as powered
device)
Not supported Not supported Not supported
System power
consumption (full
load)
20 W 13 W 11 W
Number of fans 1 None None
Operating
temperature
0°C to 45°C (30°F to 113°F)
Relative humidity
(non-condensing)
10% to 90%
Introduction to S3100-SI Series Ethernet Switches
S3100-52TP-SI
Front panel
Each S3100-52TP-SI Ethernet switch provides forty-eight auto-sensing 10/100Base-TX Ethernet ports,
two auto-sensing 10/100/1000Base-T Ethernet ports, and two 100/1000Base-X SFP ports on its front
panel.
Figure 1-1 shows the front panel of an S3100-52TP-SI Ethernet switch.
Figure 1-1 Front panel of an S3100-52TP-SI Ethernet switch
(1) Auto-sensing 10/100Base-TX port (2) Auto-sensing 10/100/1000Base-T port
(3) 100/1000Base-X SFP port (4) Power LED (Power)
(5) SFP port Speed LED (6) SFP port LINK/ACT LED
(7) 10/100/1000Base-T port LINK/ACT LED (8) 10/100/1000Base-T port Speed LED
(9) 10/100Base-TX port Speed LED (10) 10/100Base-TX port LINK/ACT LED
1-8
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the S3100-TP-SI and
S3100-TP-EI Series
”.
Rear panel
Each S3100-52TP-SI Ethernet switch provides one console port on its rear panel. Figure 1-25 shows
the rear panel of an S3100-52TP-SI Ethernet switch.
Figure 1-2 Rear panel of an S3100-52TP-SI Ethernet switch
(1) Console port (2) Grounding screw
(3) AC input terminal block
Power system
S3100-52TP-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Cooling system
The S3100-52TP-SI cools off naturally.
S3100-26TP-SI
Front panel
S3100-26TP-SI Ethernet switches each provide twenty-four auto-sensing 10/100Base-TX Ethernet
ports, two auto-sensing 10/100/1000Base-T Ethernet ports, two 100/1000Base-X SFP ports, and one
console port. Each SFP port and the corresponding auto-sensing 10/100/1000Base- T Ethernet port
form a Combo port. For each Combo port, either the SFP port or the corresponding 10/100/1000Base-T
Ethernet port can be used at a time.
Figure 1-3 shows the front panel of an S3100-26TP-SI Ethernet switch.
1-9
Figure 1-3 Front panel of an S3100-26TP-SI Ethernet switch
(1) (
2
) (4)
(5)
(6)
(7)(8)
(3)
(7)
(1) Auto-sensing 10/100Base-TX port Speed LED (green)
(2) Auto-sensing 10/100Base-TX port (3) Combo port Speed LED (green)
(4) Auto-sensing 10/100/1000Base-T port (5) Console port
(6) 100/1000Base-X SFP port (7) LINK/ACT LED (green)
(8) Power LED (PWR)
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the S3100-TP-SI and
S3100-TP-EI Series
”.
Rear panel
Figure 1-4 shows the rear panel of an S3100-26TP-SI Ethernet switch.
Figure 1-4 Rear panel of an S3100-26TP-SI Ethernet switch
(1) (2)
(1) Grounding screw (2) AC input terminal block
Power system
S3100-26TP-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Cooling system
The S3100-26TP-SI cools off naturally.
S3100-16TP-SI
Front panel
S3100-16TP-SI Ethernet switches each provide sixteen auto-sensing 10/100Base-TX Ethernet ports,
two auto-sensing 10/100/1000Base-T Ethernet ports, two 100/1000Base-X SFP ports, and one console
port. Each SFP port and the corresponding auto-sensing 10/100/1000Base- T Ethernet port form a
1-10
Combo port. For each Combo port, either the SFP port or the corresponding 10/100/1000Base- T
Ethernet port can be used at a time.
Figure 1-5 shows the front panel of an S3100-16TP-SI Ethernet switch.
Figure 1-5 Front panel of an S3100-16TP-SI Ethernet switch
(
1
)
(
2
)
(4)
(5)
(6)
(7)
(8)
(3)
(7)
(1) Auto-sensing 10/100Base-TX port Speed LED (green)
(2) Auto-sensing 10/100Base-TX port (3) Combo port Speed LED (green)
(4) Auto-sensing 10/100/1000Base-T port (5) Console port
(6) 100/1000Base-X SFP port (7) LINK/ACT LED (green)
(8) Power LED (PWR)
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the S3100-TP-SI and
S3100-TP-EI Series
”.
Rear panel
Figure 1-6 shows the rear panel of an S3100-16TP-SI Ethernet switch.
Figure 1-6 Rear panel of an S3100-16TP-SI Ethernet switch
(1) (2)
(1) Grounding screw (2) AC input terminal block
Power system
S3100-16TP-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
Cooling system
The S3100-16TP-SI cools off naturally.
1-11
S3100-8TP-SI
Front panel
S3100-8TP-SI Ethernet switches each provide eight auto-sensing 10/100Base-TX Ethernet ports, one
auto-sensing 10/100/1000Base-T Ethernet ports, one 100/1000Base-X SFP ports, and one console
port. The SFP port and the auto-sensing 10/100/1000Base- T Ethernet port form a Combo port. For the
Combo port, either the SFP port or the 10/100/1000Base- T Ethernet port can be used at a time.
Figure 1-7 shows the front panel of an S3100-8TP-SI Ethernet switch.
Figure 1-7 Front panel of an S3100-8TP-SI Ethernet switch
(1) (2) (4)
(5)
(6)(7)(8)
(3)
(7)
(1) Auto-sensing 10/100Base-TX port Speed LED (green)
(2) Auto-sensing 10/100Base-TX port (3) Combo port Speed LED (green)
(4) Auto-sensing 10/100/1000Base-T port (5) Console port
(6) 100/1000Base-X SFP port (7) LINK/ACT LED (green)
(8) Power LED (PWR)
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the S3100-TP-SI and
S3100-TP-EI Series
”.
Rear panel
Figure 1-8 shows the rear panel of an S3100-8TP-SI Ethernet switch.
Figure 1-8 Rear panel of an S3100-8TP-SI Ethernet switch
(1) (2)
(1) Grounding screw (2) AC input terminal block
Power system
S3100-8TP-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1-12
Cooling system
The S3100-8TP-SI cools off naturally.
S3100-26T-SI
Front panel
S3100-26T-SI Ethernet switches each provide twenty-four auto-sensing 10/100Base-TX Ethernet ports,
two 10/100/1000Base-T Ethernet ports, and one console port.
Figure 1-9 shows the front panel of an
S3100-26T-SI Ethernet switch.
Figure 1-9 Front panel of an S3100-26T-SI Ethernet switch
(1) Power LED (2) A/L LED
(3) D/S LED (4) Port status LED, left (yellow)
(5) Port status LED, right (green) (6) 10/100 Base-TX port
(7) 10/100/1000 Base-T port (8) Console port
(9) LINK LED (green) (10) ACT LED (yellow)
(11) Mode button
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the
S3100-T-SI/S3100-C-SI/S3100-TP-PWR-EI/ S3100-C-EPON-EI Series
”.
Rear panel
Figure 1-10 shows the rear panel of an S3100-26T-SI Ethernet switch.
Figure 1-10 Rear panel of an S3100-26T-SI Ethernet switch
(1) AC power socket (2) Grounding screw
Power system
S3100-26T-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
1-13
Cooling system
The S3100-26T-SI cools off naturally.
S3100-16T-SI
Front panel
S3100-16T-SI Ethernet switches each provide sixteen auto-sensing 10/100Base-TX Ethernet ports,
one 10/100/1000Base-T Ethernet port, and one console port.
Figure 1-11 shows the front panel of an S3100-16T-SI Ethernet switch.
Figure 1-11 Front panel of an S3100-16T-SI Ethernet switch
(1) Power LED (2) A/L LED
(3) D/S LED (4) Port status LED, left (yellow)
(5) Port status LED, right (green) (6) 10/100 Base-TX port
(7) 10/100/1000 Base-T port (8) Console port
(9) LINK LED (green) (10) ACT LED (yellow)
(11) Mode button
For details about LEDs on the front panel, refer to section “Front Panel LEDs of the
S3100-T-SI/S3100-C-SI/S3100-TP-PWR-EI/ S3100-C-EPON-EI Series
”.
Rear panel
Figure 1-12 shows the rear panel of an S3100-16T-SI Ethernet switch.
Figure 1-12 Rear panel of an S3100-16T-SI Ethernet switch
(1) AC power socket (2) Grounding screw
Power system
S3100-16T-SI Ethernet switches support AC input.
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94

H3C S3100 Series Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI