H3C S3100-8T P-EI-W Quick start guide

Category
Network switches
Type
Quick start guide

This manual is also suitable for

H3C S3100 Series Ethernet Switches
Quick Start (For Soliton)
Hangzhou H3C Technologies Co., Ltd.
http://www.h3c.com
Manual Version: T2-08011H-20080410-C-1.00
Copyright © 2008, Hangzhou H3C Technologies Co., Ltd.
and its licensors
All Rights Reserved
No part of this manual may be reproduced or transmitted in any form
or by any means without prior written consent of Hangzhou H3C
Technologies Co., Ltd.
Trademarks
H3C, , Aolynk, , H
3
Care,
, TOP G, , IRF,
NetPilot, Neocean, NeoVTL, SecPro, SecPoint, SecEngine, SecPath,
Comware, Secware, Storware, NQA, VVG, V
2
G, V
n
G, PSPT, XGbus,
N-Bus, TiGem, InnoVision and HUASAN are trademarks of Hangzhou
H3C Technologies Co., Ltd.
All other trademarks that may be mentioned in this manual are the
property of their respective owners.
Notice
The information in this document is subject to change without notice.
Every effort has been made in the preparation of this document to
ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute the warranty of
any kind, express or implied.
To obtain the latest information, please access:
http://www.h3c.com
Technical Support
customer_service@h3c.com
http://www.h3c.com
About This Manual
Related Documentation
In addition to this manual, each H3C S3100 Series Ethernet
Switches documentation set includes the following:
Manual Content
H3C S3100 Series Ethernet
Switches Operation Manual
(For Soliton)
It is used for assisting the users
in data configurations and
typical applications.
H3C S3100 Series Ethernet
Switches Command Manual
(For Soliton)
It is used for assisting the users
in using various commands.
H3C S3100 Series Ethernet
Switches Installation Manual
(For Soliton)
It is used for assisting the users
in switch installation, booting up,
hardware and software
maintenance.
Organization
H3C S3100 Series Ethernet Switches Quick Start (For Soliton) is
organized as follows:
Chapter Contents
1 Product Overview
Introduces the characteristics and
technical specifications of S3100
Series Ethernet Switches.
Chapter Contents
2 Installation Preparation
Introduces the installation
preparation and precaution of
S3100 Series Ethernet Switches.
3 Installation
Introduces the procedures to install
an S3100 Series Ethernet Switch,
including the setup of the
mainframe, cards and cables.
4 Lightning Protection of the
Switch
Introduces lightning protection of
S3100 Series Ethernet Switches.
Conventions
The manual uses the following conventions:
I.
Symbols
Convention Description
Warning
Means reader be extremely careful.
Improper operation may cause bodily
injury.
Caution
Means reader be careful. Improper
operation may cause data loss or damage
to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements
on environmental protection. For the proper storage, use and disposal
of this product, national laws and regulations must be observed.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Table of Contents
i
Table of Contents
Chapter 1 Product Overview ........................................................1-1
1.1 Overview ............................................................................1-1
1.2 Introduction to S3100 Series Ethernet Switches ...............1-2
1.2.1 S3100-26TP-EI-W ...................................................1-2
1.2.2 S3100-16TP-EI-W ...................................................1-4
1.2.3 S3100-8TP-EI-W .....................................................1-7
1.3 Introduction to Front Panel LEDs.......................................1-9
1.3.1 Power LED ..............................................................1-9
1.3.2 Auto-Sensing 10/100BASE-TX Ethernet Port Status
LED.................................................................................
1-10
1.3.3 1000 Mbps Uplink Port Status LED.......................1-12
1.4 Technical Specifications ..................................................1-12
1.5 SFP Modules Supported by S3100 Series Ethernet
Switches ................................................................................
1-14
Chapter 2 Installation Preparation...............................................2-1
2.1 Precautions ........................................................................2-1
2.2 Requirements on Environment ..........................................2-1
2.2.1 Temperature/Humidity Requirements .....................2-2
2.2.2 Cleanness Requirements ........................................2-3
2.2.3 Anti-interference Requirements...............................2-4
2.2.4 Laser Usage Security ..............................................2-5
2.3 Installation Tools ................................................................2-5
Chapter 3 Installation....................................................................3-1
3.1 Installing a Switch ..............................................................3-1
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Table of Contents
ii
3.1.1 Cabinet Mounting ....................................................3-1
3.1.2 Desk Mounting.........................................................3-9
3.1.3 Wall Mounting..........................................................3-9
3.1.4 Magnet Mounting...................................................3-12
3.2 Connection of Power Cord and Grounding Cable ...........3-16
3.2.1 Connecting AC Power Cord ..................................3-16
3.2.2 Connecting DC Power Cable ................................3-17
3.2.3 Connecting Grounding Cable ................................3-19
3.3 Connecting Optical Fiber .................................................3-24
3.4 Connection of Console Cable ..........................................3-25
3.4.1 Console Cable .......................................................3-25
3.4.2 Connecting Console Cable....................................3-26
3.5 Installation Verification .....................................................3-27
Chapter 4 Lightning Protection of the Switch ............................4-1
4.1 Installation of Lightning Arrester for AC Power (Socket Strip
with Lightning Protection).........................................................
4-1
4.2 Installation of Lightning Arrester for Network Port .............4-4
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-1
Chapter 1 Product Overview
1.1 Overview
H3C S3100 Series Ethernet Switches are high-performance,
high-density, easy-to-install, NMS-manageable intelligent Ethernet
switches which support wire-speed Layer 2 switching.
Table 1-1 lists the models of H3C S3100 Series Ethernet
Switches.
Table 1-1 Models of H3C S3100 Series Ethernet Switches
Model
Power
supply
Number of
10/100M
electrical
ports
1000M
uplink
ports
Number of
console
ports
S3100-26T
P-EI-W
AC input or
12V-RPS
DC input
24
2 Combo
ports
1
S3100-16T
P-EI-W
16
2 Combo
ports
1
S3100-8T
P-EI-W
AC input
8
1 Combo
port
1
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-2
1.2 Introduction to S3100 Series Ethernet
Switches
1.2.1 S3100-26TP-EI-W
I. Front panel
S3100-26TP-EI-W Ethernet switches each provide twenty-four
auto-sensing 10/100/1000Base-TX Ethernet ports, two
10/100/1000BASE-T Ethernet ports, two 100/1000Base-X SFP ports,
and one console port. Each SFP port and the corresponding
10/100/1000BASE-T Ethernet port form a Combo port. For each
Combo port, either the SFP port or the corresponding
10/100/1000BASE-T Ethernet port can be used at a time.
Figure 1-1 shows the front panel of an S3100-26TP-EI-W
Ethernet switch.
(1) (2) (3) (4) (5)
(6)(7)(8)(9)
(1) Auto-sensing 10/100Base-TX Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) RPS DC power LED
(6) A/L LED (7) D/S LED
(8) Mode button (9) Active LED for Combo port
Figure 1-1 Front panel of an S3100-26TP-EI-W Ethernet switch
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-3
Note:
For details about LEDs on the front panel, refer to section 1.3
Introduction to Front Panel LEDs”.
II. Rear panel
Figure 1-2 shows the rear panel of an S3100-26TP-EI-W
Ethernet switch.
(1) (2) (3)
(1) AC power socket (2) RPS DC power socket
(3) Grounding screw
Figure 1-2 Rear panel of an S3100-26TP-EI-W Ethernet switch
III. Power system
S3100-26TP-EI-W Ethernet switches can adopt AC input, or RPS
12 VDC input, or both to provide backup. Only the recommended RPS
can be used.
1) AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz
2) RPS DC input:
z Rate voltage range: 10.8 VDC to 13.2 VDC
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-4
IV. Cooling system
S3100-26TP-EI-W Ethernet switches cool off naturally.
1.2.2 S3100-16TP-EI-W
I. Front panel
S3100-16TP-EI-W Ethernet switches each provide sixteen
auto-sensing 10/100Base-TX Ethernet ports, two 10/100/1000Base-T
Ethernet ports, two 100/1000Base-X SFP ports, and one console port.
Each SFP port and the corresponding 10/100/1000BASE-T Ethernet port
form a Combo port. For each Combo port, either the SFP port or the
corresponding 10/100/1000BASE-T Ethernet port can be used at a time.
Figure 1-3 shows the front panel of an S3100-16TP-EI-W
Ethernet switch.
(1) (2) (3) (4)
(5)(6)(7)(8)
(1) Auto-sensing 10/100Base-TX Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) A/L LED
(6) D/S LED (7) Mode button
(8) Active LED for Combo port
Figure 1-3 Front panel of an S3100-16TP-EI-W Ethernet switch
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-5
Note:
For details about LEDs on the front panel, refer to section 1.3
Introduction to Front Panel LEDs”.
II. Rear panel
Figure 1-4 shows the rear panel of an S3100-16TP-EI-W
Ethernet switch.
(1) (2)
(1) AC power socket (2) Grounding screw
Figure 1-4 Rear panel of an S3100-16TP-EI-W Ethernet switch
III. Side panel
Each S3100-16TP-EI-W Ethernet switch provides a security slot,
through which you can lock the device together with an irremovable
object to prevent theft.
The security slot is located at the rear end of the left side panel,
as shown in
Figure 1-5.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-6
(1)
(1) Security slot
Figure 1-5 Security slot on left side panel of an
S3100-16TP-EI-W Ethernet switch
Note:
If the left screw hole above the security slot is used, the security slot
cannot be used.
IV. Power system
S3100-16TP-EI-W Ethernet switches:
z Rated voltage range: 100 VAC to 240 VAC, 50/60Hz
z Input voltage range: 90 VAC to 264 VAC, 47Hz to 63Hz
V. Cooling system
S3100-16TP-EI-W Ethernet switches cool off naturally.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-7
1.2.3 S3100-8TP-EI-W
I. Front panel
S3100-8TP-EI-W Ethernet switches each provide eight
auto-sensing 10/100Base-TX Ethernet ports, one 10/100/1000Base-T
Ethernet port, one 100/1000Base-X SFP port, and one console port.
The SFP port and the 10/100/1000BASE-T Ethernet port form a
Combo port. Either the SFP port or the 10/100/1000BASE-T Ethernet
port can be used at a time.
Figure 1-6 shows the front panel of an S3100-8TP-EI-W Ethernet
switch.
(1) (2) (3) (4)
(5)(6)(7)(8)
(1) Auto-sensing 10/100Base-TX Ethernet port status LED
(2) Link LED for Combo port (3) Console port
(4) Power LED (PWR) (5) A/L LED
(6) D/S LED (7) Mode button
(8) Active LED for Combo port
Figure 1-6 Front panel of an S3100-8TP-EI-W Ethernet switch
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-8
Note:
For details about LEDs on the front panel, refer to section 1.3
Introduction to Front Panel LEDs”.
II. Rear panel
Figure 1-7 shows the rear panel of an S3100-8TP-EI-W Ethernet
switch.
(1) (2)
(1) AC power socket (2) Grounding screw
Figure 1-7 Rear panel of an S3100-8TP-EI-W Ethernet switch
III. Side panel
Each S3100-8TP-EI-W Ethernet switch provides a security slot,
through which you can lock the device together with an irremovable
object to prevent theft.
The security slot is located at the rear end of the left side panel,
as shown in
Figure 1-5.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-9
Note:
If the left screw hole above the security slot is used, the security slot
cannot be used.
IV. Power system
S3100-8TP-EI-W Ethernet switches:
z Rated voltage range: 100 VAC to 240 VAC, 50/60Hz
z Input voltage range: 90 VAC to 264 VAC, 47Hz to 63Hz
V. Cooling system
S3100-8TP-EI-W Ethernet switches cool off naturally.
1.3 Introduction to Front Panel LEDs
1.3.1 Power LED
Table 1-2 Description of the power LED on S3100 series
LED
Mark on
the panel
Status Description
ON The switch is powered on.
Power LED PWR
OFF The switch is powered off.
ON DC input is normal.
RPS DC
power LED
RPS
OFF There is no DC input.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-10
Note:
Only S3100-26TP-EI-W AC-powered Ethernet switches have an RPS
DC power LED.
1.3.2 Auto-Sensing 10/100BASE-TX Ethernet Port
Status LED
There are two port status LEDs on both sides (yellow LED on the
left and green LED on the right) of each 10/100BASE-TX Ethernet port
of S3100 series. They indicate the active, link, duplex, and speed
statuses of the port.
In addition, there are an A/L LED and a D/S LED on each model
of S3100 series. These two LEDs indicate the mode of the port status
LEDs. When the A/L LED is on, the port status LEDs respectively
indicate the active status and link status of ports. When the D/S LED is
on, the port status LEDs respectively indicate the duplex status and
speed status of ports. Either the A/L LED or the D/S LED is on at a
specific time. For details, see
Table 1-3.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-11
Table 1-3 Description of port status LEDs on S3100 series
Port status
mode LED
Port status LED Description
BLINKING
The port is in the active state
and there is traffic on the port.
Yellow
LED
(left)
OFF
The port is in the active state
but there is no traffic on the
port.
ON
The port is connected
properly.
The A/L
LED is on
Green
LED
(right)
OFF
The port is not connected or
is incorrectly connected.
ON
The port operates in the full
duplex mode.
Yellow
LED
(left)
OFF
The port operates in the half
duplex mode.
ON The port rate is 100 Mbps.
The D/S
LED is on
Green
LED
(right)
OFF The port rate is 10 Mbps.
You can switch the mode of the port status LEDs by pressing the
Mode button. After a switch is powered on, the A/L LED is on initially. If
you press the Mode button, the D/S LED will be on. After that, if you
press the Mode button again within 45 seconds, the A/L LED will be on
again. Otherwise, the A/L LED will automatically be on 45 seconds
later.
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-12
1.3.3 1000 Mbps Uplink Port Status LED
Table 1-4 Description of 1000 Mbps uplink port status LED on
S3100 series
LED
Mark on
the panel
Status Description
ON
The port is connected
properly.
1000
Mbps
uplink port
link LED
LINK
OFF
The port is not connected
or is incorrectly connected.
BLINKING
The port is in the active
state and there is traffic on
the port.
1000
Mbps
uplink port
active
LED
ACT
OFF
The port is in the active
state but there is no traffic
on the port.
1.4 Technical Specifications
Table 1-5 Technical specifications for S3100 Series Ethernet
switches
Model
S3100-26TP-
EI-W
S3100-16TP-
EI-W
S3100-8TP-EI
-W
Physical
dimensions (H
x W x D)
43.6 x 440 x
260 mm (1.7 x
17.2 x 10.2 in)
43.6 x 300 x
220 mm (1.7 x
11.8 x 8.7 in)
43.6 x 230 x
200 mm (1.7 x
9.1 x 7.9 in)
Weight <3.5 kg (7.7 lb) <2.5 kg (5.5 lb) <1.8 kg (4 lb)
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-13
Model
S3100-26TP-
EI-W
S3100-16TP-
EI-W
S3100-8TP-EI
-W
Number of
fixed ports
24 x
auto-sensing
10/100BASE-
TX Ethernet
port
2 x 1000M
Combo port
16 x
auto-sensing
10/100BASE-
TX Ethernet
port
2 x 1000M
Combo port
8 x
auto-sensing
10/100BASE-
TX Ethernet
port
1 x 1000M
Combo port
Number of
management
port
1 x console port
Power system
S3100-16TP-EI-W/S3100-8TP-EI-W Ethernet
switches support only AC input.
S3100-26TP-EI-W AC-powered switches support
AC input and RPS DC input.
AC input:
z Rated voltage range: 100 VAC to 240 VAC, 50
Hz /60 Hz
z Input voltage range: 90 VAC to 264 VAC, 47
Hz to 63Hz
RPS DC input:
z Input voltage range: 10.8 VDC to 13.2 VDC
PoE (as
powered
device)
Not supported Not supported Not supported
System power
consumption
(full load)
22 W 17 W 14 W
Fan None None None
Operating
temperature
0°C to 45°C (30°F to 113°F)
Quick Start (For Soliton)
H3C S3100 Series Ethernet Switches
Chapter 1 Product Overvie
w
1-14
Model
S3100-26TP-
EI-W
S3100-16TP-
EI-W
S3100-8TP-EI
-W
Relative
humidity (non-
condensing)
10% to 90%
Caution:
Only the recommended 12V-RPS DC power supply can be used for
S3100-26TP-EI Ethernet switches.
1.5 SFP Modules Supported by S3100
Series Ethernet Switches
The front panel of S3100 Series Ethernet switches provides one
or two 1000M SFP ports in which you can select the required small
form-factor pluggable (SFP) modules to insert. For the models of SFP
modules, see
Table 1-6.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

H3C S3100-8T P-EI-W Quick start guide

Category
Network switches
Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI