RAB Lighting RMKPANEL2X4 Operating instructions

Type
Operating instructions

This manual is also suitable for

RMKPANEL2X4 - RECESSED DRYWALL KIT
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
SAFETY INSTRUCTIONS
WARNING: Risk of re or electric shock. Suitable for Damp
locations.
WARNING: Install Drywall Kit & Panel per local codes.
Suitable for installation in Sheet Rock/ Plasterboard in
both Insulated Ceilings and Non-Insulated Ceilings. Not for
continuous row mounting.
WARNING: Do not handle energized xture when hands are
wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90 ͦ C.
WARNING: Drywall kit to be independently supported to
building structure.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
Make certain power is OFF before installing or maintaining xture.
DRYWALL MOUNTING
The xture is suitable only for INDOOR RECESSED CEILING
application. Nominal Sheet Rock cut-out opening is
24 5/8” x 48 5/8”.
To mount in an insulated or non-insulated - sheet rock ceiling
follow the steps below.
1. Assemble the four pieces of the Drywall Kit 2X4 with the
screws provided.
2. Support the Drywall Kit 2x4 to the building structure by
Hanger Wires (by others), alternatively screw to Wood
Blocking (by others) or black iron (by others).
3. Bend the pre-installed Clips (4) at to the PANEL 2X4
Housing.
4. Follow wiring directions on xture installation instruction
sheet to complete electrical splices.
5. Rotate and slide the PANEL 2X4 Housing as required
to t through the drywall opening as indicated by the
directional arrow in gure and place it on the Drywall Kit.
PANEL 2X4 Housing
(Available upon request)
Clip
Drywall Kit 2X4
5 ”
A
A
B B
C C
D D
4
1234
23
R
AB
1.500
[38,1]
1.125
[28,56]
1.125
[28,58]
.250
[6,35]
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
SHEET ROCK FLANGE KITS
1X4, 2X4, 2X2
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
8-5-2013
DRAWN BY:
CDS
SCALE SHEET:
2 OF 2
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
NO. NAME QUANTITY PART NO. MATERIAL
1 SCREW_SLF_TAP_8-32_0375 2
2 SHFK_24 4
SEE DETAIL A
SCALE 0.500
DETAIL A
Hanger Wires (by others)
Drywall Kit 2X4
Order CAT# RMKPANEL2X4
Drywall Kit 2X4
Wood Blocking (by others)
RMKPANEL2X4 IN-1013
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
5 ”
RMKPANEL1X4 - RECESSED DRYWALL KIT
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
SAFETY INSTRUCTIONS
WARNING: Risk of re or electric shock. Suitable for Damp
locations.
WARNING: Install Drywall Kit & Panel per local codes.
Suitable for installation in Sheet Rock/ Plasterboard in
both Insulated Ceilings and Non-Insulated Ceilings. Not for
continuous row mounting.
WARNING: Do not handle energized xture when hands are
wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90 ͦ C.
WARNING: Drywall kit to be independently supported to
building structure.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
Make certain power is OFF before installing or maintaining xture.
DRYWALL MOUNTING
The xture is suitable only for INDOOR RECESSED CEILING
application. Nominal Sheet Rock cut-out opening is
12 5/8” x 48 5/8”.
To mount in an insulated or non-insulated - sheet rock ceiling
follow the steps below.
1. Assemble the four pieces of the Drywall Kit 1X4 with the
screws provided.
2. Support the Drywall Kit 1x4 to the building structure by
Hanger Wires (by others), alternatively screw to Wood
Blocking (by others) or black iron (by others).
3. Bend the pre-installed Clips (4) at to the PANEL 1X4
Housing.
4. Follow wiring directions on xture installation instruction
sheet to complete electrical splices.
5. Rotate and slide the PANEL 1X4 Housing as required
to t through the drywall opening as indicated by the
directional arrow in gure and place it on the Drywall Kit.
PANEL 1X4 Housing
(Available upon request)
Clip
Drywall Kit 1X4
5 ”
A
A
B B
C C
D D
4
1234
23
R
AB
1.500
[38,1]
1.125
[28,56]
1.125
[28,58]
.250
[6,35]
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
SHEET ROCK FLANGE KITS
1X4, 2X4, 2X2
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
8-5-2013
DRAWN BY:
CDS
SCALE SHEET:
2 OF 2
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
NO. NAME QUANTITY PART NO. MATERIAL
1 SCREW_SLF_TAP_8-32_0375 2
2 SHFK_24 4
SEE DETAIL A
SCALE 0.500
DETAIL A
Hanger Wires (by others)
Drywall Kit 1X4
Order CAT# RMKPANEL1X4
Drywall Kit 1X4
Wood Blocking (by others)
RMKPANEL1X4 IN-1013
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
5 ”
RMKPANEL2X2 - RECESSED DRYWALL KIT
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
SAFETY INSTRUCTIONS
WARNING: Risk of re or electric shock. Suitable for Damp
locations.
WARNING: Install Drywall Kit & Panel per local codes.
Suitable for installation in Sheet Rock/ Plasterboard in
both Insulated Ceilings and Non-Insulated Ceilings. Not for
continuous row mounting.
WARNING: Do not handle energized xture when hands are
wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90 ͦ C.
WARNING: Drywall kit to be independently supported to
building structure.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
Make certain power is OFF before installing or maintaining xture.
DRYWALL MOUNTING
The xture is suitable only for INDOOR RECESSED CEILING
application. Nominal Sheet Rock cut-out opening is
24 5/8” x 24 5/8”.
To mount in an insulated or non-insulated - sheet rock ceiling
follow the steps below.
1. Assemble the four pieces of the Drywall Kit 2X2 with the
screws provided.
2. Support the Drywall Kit 2x2 to the building structure by
Hanger Wires (by others), alternatively screw to Wood
Blocking (by others) or black iron (by others).
3. Bend the pre-installed Clips (4) at to the PANEL 2X2
Housing.
4. Follow wiring directions on xture installation instruction
sheet to complete electrical splices.
5. Rotate and slide the PANEL 2X2 Housing as required
to t through the drywall opening as indicated by the
directional arrow in gure and place it on the Drywall Kit.
PANEL 2X2 Housing
(Available upon request)
Clip
Drywall Kit 2X2
5 ”
A
A
B B
C C
D D
4
1234
23
R
AB
1.500
[38,1]
1.125
[28,56]
1.125
[28,58]
.250
[6,35]
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
SHEET ROCK FLANGE KITS
1X4, 2X4, 2X2
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
8-5-2013
DRAWN BY:
CDS
SCALE SHEET:
2 OF 2
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
NO. NAME QUANTITY PART NO. MATERIAL
1 SCREW_SLF_TAP_8-32_0375 2
2 SHFK_24 4
SEE DETAIL A
SCALE 0.500
DETAIL A
A
A
B B
C C
D D
4
1234
23
R
AB
1.500
[38,1]
1.125
[28,56]
1.125
[28,58]
.250
[6,35]
L I G H T I N G 170 LUDLOW AVE., NORTHVALE, NJ 07647
TITLE
SHEET ROCK FLANGE KITS
1X4, 2X4, 2X2
MATERIAL: PART No.: DRAWING NAME:
DATE: REV DATE: REV
8-5-2013
DRAWN BY:
CDS
SCALE SHEET:
2 OF 2
THIS DRAWING AND THE INFORMATION IT DISCLOSES IS THE EXCLUSIVE
PROPERTY OF RAB LIGHTING, INCORPORATED
ANY REPRODUCTION OR USE OF THIS DRAWING WITHOUT THE WRITTEN CONSENT OF
RAB LIGHTING, INC. IS STRICTLY PROHIBITED. RAB CONFIDENTIAL PATENT PENDING
REV DESCRIPTION DATE
1
NO. NAME QUANTITY PART NO. MATERIAL
1 SCREW_SLF_TAP_8-32_0375 2
2 SHFK_24 4
SEE DETAIL A
SCALE 0.500
DETAIL A
Hanger Wires (by others)
Drywall Kit 2X2
Order CAT# RMKPANEL2X2
Drywall Kit 2X2
Wood Blocking (by others)
RMKPANEL2X2 IN-0913
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2013 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
5 ”
  • Page 1 1
  • Page 2 2
  • Page 3 3

RAB Lighting RMKPANEL2X4 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI