Introduction
When connected to the RE5000 Control Unit, the
RE5000AD may be used to communicate up to three
separate message phrases (usually relating to Intruder,
Fire and Medical Alert conditions). The Dialler Tamper
Switch may be connected to Zone 6 on the RE5000CU
if tamper protection is required.
The Communicator Interface Cable connection supplied
with the RE5000 Control Unit allows simple connection
between the Control Unit and Dialler.
THE FOLLOWING MUST BE READ IN CONJUNCTION
WITH THE RE5000AD (TSD1+) INSTALLATION AND
OPERATING INSTRUCTIONS SUPPLIED AND THE
RE5000 INSTALLATION AND OPERATING MANUAL.
CONNECTING THE RE5000AD TO
THE RE5000 CONTROL UNIT.
1.
Disconnect all power (Mains and Back-up Battery)
from the Control Unit before making any connections.
2. Plug the Interface Cable into the Control Unit plug
and connect the lead to the Dialler as shown.
3. Ensure that all cabling is connected correctly and that
all unused cores of the Interface Cable are cut back or
insulated to prevent accidental short circuits.
4. Connect the Telephone Cable to the Dialler - (see
Dialler Installation Instructions).
5. Reconnect power to the Control Unit and proceed to
programme and test the Dialler in accordance with
the Dialler Operators Manual.
Note:
If your RE5000CU is supplied with an 8-Core
interface cable, please call our Technical
Helpline for connection advice.