ioThinx 4500 Series Modules

Moxa ioThinx 4500 Series Modules Quick setup guide

  • Hello! I am an AI chatbot trained to assist you with the Moxa ioThinx 4500 Series Modules Quick setup guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • How many modules are in the Moxa ioThinx 4500 Series?
    How do I install a 45ML module on a DIN rail?
    What is the operating temperature range for the Moxa ioThinx 4500 Series?
    What is the storage temperature range for the Moxa ioThinx 4500 Series?
    What type of cables are recommended for wiring the 45ML-5401 module?
P/N: 1802045002010
*1802045002010*
ioThinx 4500 (45ML) Module
Series
Quick Installation Guide
Version 1.0, April 2020
Technical Support Contact Information
www.moxa.com/support
Moxa Americas:
Toll
-free: 1-888-669-2872
Tel:
1-714-528-6777
Fax:
1-714-528-6778
Moxa China (Shanghai office):
Toll
-free: 800-820-5036
Tel:
+86-21-5258-9955
Fax:
+86-21-5258-5505
Moxa Europe:
Tel:
+49-89-3 70 03 99-0
Fax:
+49-89-3 70 03 99-99
Moxa Asia-Pacific:
Tel:
+886-2-8919-1230
Fax:
+886-2-8919-1231
Moxa India:
Tel:
+91-80-4172-9088
Fax:
+91-80-4132-1045
2020 Moxa Inc. All rights reserved.
- 2 -
Package Checklist
1 x ioThinx 4500 (45ML) module
1 x quick installation guide (printed)
1 x warranty card
Installation
Installing a 45ML Module on a DIN Rail
Step 1: Align the 45ML module side by side
with the head/CPU module, making sure that
the upper and lower rails are hooked together.
Step 2: After aligning the 45ML module side by side with the head/CPU
module, push the 45ML module until it touches the DIN rail. Next, apply
more force until the module clips to the DIN rail.
NOTE
Removing a 45ML Module from a DIN Rail
Step 1:
Use your finger to lift the
release tab on the lower part of the
module.
- 3 -
Step 2: Push the top of the release tab to latch it, and then pull the
module out.
NOTE
NOTE
s can
used with an ioThinx 4500 Series product that has the
installed on the left side of the head/CPU
the ioThinx 4510 Series does not support 45ML
ore removing modules to avoid
Installing the Covers on the First and Last Module
Attach the covers to the first and last module to cover the modules
contacts.
- 4 -
Horizontal Installation
Before installing the
device, make sure there is
enough space between
the device and nearby
walls, other devices, etc.
,
to ensure proper heat
dissipation.
To ensure that the device
works properly, we
suggest reserving the
amount of space indicated
in the adjacent figure.
AUTION
. If the device is installed
LED Indicators
Labeling
Indication
Description
Status Status Green: Module ready
Green Slow Blinking: Booting up
Red: Module error
Red Slow Blinking: Upgrading firmware
Off: Power off
Port 1, Port 2,
Port 3, Port 4
Serial
connection
Green: Transmitting data
Amber: Receiving data
Off: Disconnected or data is not being
transmitted
Module Configuration
Please refer to the ioThinx 4500 Series User’s Manual.
- 5 -
Specifications
Input Current
Varies per module; please refer to the datasheet
Input Voltage
System power:
12 to 48 V, via the ioThinx 4533
Field Power:
12/24 V, via the ioThinx 4533
Operating
Temperature
Standard Models: -20 to 60°C (-4 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage
Temperature
-40 to 85°C (-40 to 185°F)
Attention
1. This device is only for indoor use in environments with pollution
degree 2.
2. For surge protection, connect the DIN rail to earth ground.
3. Cables rated for a minimum temperature of 105°C must be used for
the Power Supply Terminal.
4. We suggest using the following cable types for wiring:
45ML-5401:
> AWG 18 to 24
Moxa Inc.
Fl.4, No. 135, Lane 235, Baoqiao Rd.
Xindian Dist., New Taipei City, Taiwan R.O.C.
/