American Standard T005.5XX User manual

Category
Sanitary ware
Type
User manual

American Standard T005.5XX is a pressure balancing bath and shower trim kit that offers precise temperature control and a comfortable showering experience. Its key features include:

  • Adjustable Hot Limit Stop: This safety feature allows you to set a maximum hot water temperature to prevent accidental scalding.

  • Easy Installation: The trim kit comes with clear instructions and all necessary mounting hardware for a hassle-free installation process.

  • Durable Construction: Made from high-quality materials, the trim kit ensures longevity and reliable performance.

American Standard T005.5XX is a pressure balancing bath and shower trim kit that offers precise temperature control and a comfortable showering experience. Its key features include:

  • Adjustable Hot Limit Stop: This safety feature allows you to set a maximum hot water temperature to prevent accidental scalding.

  • Easy Installation: The trim kit comes with clear instructions and all necessary mounting hardware for a hassle-free installation process.

  • Durable Construction: Made from high-quality materials, the trim kit ensures longevity and reliable performance.

Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" FOR HEAD
CLEARANCE
4-1/4" REF.
1-5/8" TO 3"
18" OPTIONAL
4-7/8" REF.
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-1/2"
1-1/2"
6" REF.
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78'
"SEE ILLUSTRATION "
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
COPELAND
SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
M962606-YYY0A
SHOWER ARM
AND FLANGE
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
M953579-YYY0A
SHOWER HEAD
Installation
Instructions
T005.5XX
T005.5XX
COPELAND
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
M968636 Rev 1.1
M968636 Rev 1.1 M968636 Rev 1.1 M968636 Rev 1.1
7
8
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX
WRENCH
4
HANDLE INSTALLATION
3
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2. Figure 3.
3
5
6
4
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8)
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5)
and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
9
5
PIPE
PLUG
PIPE
CAP
1
4
3
2
SHR.
ELBOW
TUB FILLER
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with
4mm Hex Wrench.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER
ARM (3). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (3) and thread longer
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
M962607-YYY0A
HANDLE
M962427-0070A
ESCUTCHEON HOLDER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r ademarks of American Standard I n c .
© A m e r i c a n S t a n d a r d I n c . 2 0 0 7
IN MEXICO 01-800-839-12-00
CHROME
SATIN NICKEL
BLACKENED BRONZE
002
295
068
Replace the "YYY" with
appropriate finish code
4MM HEX
WRENCH
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" FOR HEAD
CLEARANCE
4-1/4" REF.
1-5/8" TO 3"
18" OPTIONAL
4-7/8" REF.
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-1/2"
1-1/2"
6" REF.
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78'
"SEE ILLUSTRATION "
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
COPELAND
SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
M962606-YYY0A
SHOWER ARM
AND FLANGE
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
M953579-YYY0A
SHOWER HEAD
Installation
Instructions
T005.5XX
T005.5XX
COPELAND
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
M968636 Rev 1.1
M968636 Rev 1.1 M968636 Rev 1.1 M968636 Rev 1.1
7
8
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX
WRENCH
4
HANDLE INSTALLATION
3
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2. Figure 3.
3
5
6
4
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8)
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5)
and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
9
5
PIPE
PLUG
PIPE
CAP
1
4
3
2
SHR.
ELBOW
TUB FILLER
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with
4mm Hex Wrench.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER
ARM (3). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (3) and thread longer
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
M962607-YYY0A
HANDLE
M962427-0070A
ESCUTCHEON HOLDER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r ademarks of American Standard I n c .
© A m e r i c a n S t a n d a r d I n c . 2 0 0 7
IN MEXICO 01-800-839-12-00
CHROME
SATIN NICKEL
BLACKENED BRONZE
002
295
068
Replace the "YYY" with
appropriate finish code
4MM HEX
WRENCH
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" FOR HEAD
CLEARANCE
4-1/4" REF.
1-5/8" TO 3"
18" OPTIONAL
4-7/8" REF.
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-1/2"
1-1/2"
6" REF.
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78'
"SEE ILLUSTRATION "
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
COPELAND
SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
M962606-YYY0A
SHOWER ARM
AND FLANGE
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
M953579-YYY0A
SHOWER HEAD
Installation
Instructions
T005.5XX
T005.5XX
COPELAND
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
M968636 Rev 1.1
M968636 Rev 1.1 M968636 Rev 1.1 M968636 Rev 1.1
7
8
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX
WRENCH
4
HANDLE INSTALLATION
3
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2. Figure 3.
3
5
6
4
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8)
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5)
and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
9
5
PIPE
PLUG
PIPE
CAP
1
4
3
2
SHR.
ELBOW
TUB FILLER
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with
4mm Hex Wrench.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER
ARM (3). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (3) and thread longer
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
M962607-YYY0A
HANDLE
M962427-0070A
ESCUTCHEON HOLDER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r ademarks of American Standard I n c .
© A m e r i c a n S t a n d a r d I n c . 2 0 0 7
IN MEXICO 01-800-839-12-00
CHROME
SATIN NICKEL
BLACKENED BRONZE
002
295
068
Replace the "YYY" with
appropriate finish code
4MM HEX
WRENCH
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
Recommended Tools
Flat Blade Screwdriver
Adjustable Wrench
Channel Locks
Plumbers' Putty or Caulking
Phillips Screwdriver
Teflon Tape
FINISHED WALL
4"
TOP OF TUB RIM
BOTTOM OF TUB
74" FOR HEAD
CLEARANCE
4-1/4" REF.
1-5/8" TO 3"
18" OPTIONAL
4-7/8" REF.
1/2" NPT
1/2" COPPER
FOR SLIP-ON
SPOUT
7-1/2"
1-1/2"
6" REF.
OPTIONAL TO FINISHED
FLOOR USUALLY
BETWEEN 65'' AND 78'
"SEE ILLUSTRATION "
Certified to comply with ANSI A112.18.1
ROUGHING-IN DIMENSIONS (For reference only)
To assure proper positioning in relation to wall, note roughing-in dimensions.
PRESSURE BALANCING BATH
AND SHOWER TRIM KITS
COPELAND
SERVICE
5
Remove HANDLE (1), CAP (2) and CARTRIDGE (4). Clean inlets
and MANIFOLD (5).
Reassemble CARTRIDGE (4), alternately tightening SCREWS (3).
Replace CAP (2) and HANDLE (1). Check flow.
If faucet drips, operate handle several times from "off"
to "on". Do not apply excessive force.
Clogged CARTRIDGE (4) inlets may cause reduced flow in "full
on" hot or cold. To clean inlets, first turn off water supply, then:
5
4
3
2
1
6
PRESSURE BALANCE
BATH/SHOWER
MODEL NUMBER
M962606-YYY0A
SHOWER ARM
AND FLANGE
M950234-YYY0A
DIVERTER SPOUT (SLIP-ON)
M953579-YYY0A
SHOWER HEAD
Installation
Instructions
T005.5XX
T005.5XX
COPELAND
THREADED INLETS (STOPS)
INLETS
1/2" NPT
5-7/8"
INLETS 1/2" NPT
OUTLETS
1/2" NPT
OUTLETS
1/2" NPT
3-3/8"
3-3/8"
3-3/8"
THREADED INLETS
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
4-1/16"
5-7/8"
INLETS
4-1/16"
4-1/16"
INLETS
1/2" NOM.
COPPER
SWEAT
SHR. 1/2" NOM.
COPPER SWEAT
TUB 1/2" NOM.
COPPER SWEAT
2"
SWEAT
INLETS
SWEAT
INLETS (STOPS)
INLETS
1/2" NOM.
COPPER
SWEAT
M968636 Rev 1.1
M968636 Rev 1.1 M968636 Rev 1.1 M968636 Rev 1.1
7
8
"B"
"B"
3
ADJUST HOT LIMIT STOP
By restricting handle rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP reduces risk of accidental scalding. To set
the maximum hot water temperature of your faucets, all
you need to do is adjust the setting on the HOT LIMIT
SAFETY STOP.
Use a flat blade screwdriver or your fingers to pull
up and rotate red HOT LIMIT SAFETY STOP (1).
Follow Step "A" or "B" to adjust min./max. discharge
temperature. "0" being the hottest to "7" the coldest
temperature setting. Factory set at "0".
HOT LIMIT SAFETY STOP ADJUSTMENT
PRY RED RING
FORWARD AND ROTATE
COUNTER-CLOCKWISE
ONE CLICK
PRY RED RING
FORWARD AND
ROTATE CLOCKWISE
"A"
"A"
ADJUSTMENT WHEN
WATER IS TOO HOT
ADJUSTMENT WHEN
WATER IS TOO COLD
"RED RING"- HOT
LIMIT SAFETY STOP
TEMPERATURE
SETTING
NUMBERS
1
0
1
2
3
4
5
6
1
2.5MM HEX
WRENCH
4
HANDLE INSTALLATION
3
1
INSTALL VALVE TRIM
1
Figure 1.
Figure 2. Figure 3.
3
5
6
4
2
1
Figure 1. Remove plaster guard from valve. Push CAP (1)
over VALVE CARTRIDGE (2) until seated against stop.
Figure 2. Push ESCUTCHEON HOLDER (3) onto CAP (1)
and attach with LONG SCREWS (4). Mount ESCUTCHEON
SUPPORT (5) to ESCUTCHEON HOLDER (3) with 4 SHORT
SCREWS (6).
Figure 3. Align PINS (7) on back side of ESCUTCHEON (8)
with the FOUR HOLES (9) in ESCUTCHEON SUPPORT (5)
and press ESCUTCHEON (8) flush against finished wall.
PLSTER
GUARD
9
5
PIPE
PLUG
PIPE
CAP
1
4
3
2
SHR.
ELBOW
TUB FILLER
NIPPLE
1-1/2" REF.
Remove pipe cap and plug from shower and tub
rough piping.
Slip TUB SPOUT (1) onto tub nipple and tighten with
4mm Hex Wrench.
CAUTION: Protect finish on TUB SPOUT when
installing.
Install SHOWER ESCUTCHEON (2) onto SHOWER
ARM (3). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (3) and thread longer
leg of SHOWER ARM (3) into shower elbow.
Thread SHOWER HEAD (4) onto SHOWER ARM (3).
2
INSTALL TUB SPOUT, SHOWER HEAD,
SHOWER ARM WITH FLANGE
CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.
CAUTION: Protect finish on SHOWER
HEAD and TUB SPOUT when installing.
Install HANDLE (1) by pushing it onto CARTRIDGE STEM (2)
and tightening SET SCREW (3) from below with 2.5mm
Hex Wrench supplied.
2
M907050-YYY0A
CAP
M962605-YYY0A
ESCUTCHEON AND SEAL
M962607-YYY0A
HANDLE
M962427-0070A
ESCUTCHEON HOLDER
HOT LINE FOR HELP
For toll-free information and answers to your questions, call:
1 (800) 442-1902
Weekdays 8:00 a.m. to 6:00 p.m. EST
IN CANADA 1-800-387-0369 (TORONTO 1-905-306-1093)
Weekdays 8:00 a.m. to 7:00 p.m. EST
Pr o d u c t n a m e s l i s t e d h e r e i n a r e t r ademarks of American Standard I n c .
© A m e r i c a n S t a n d a r d I n c . 2 0 0 7
IN MEXICO 01-800-839-12-00
CHROME
SATIN NICKEL
BLACKENED BRONZE
002
295
068
Replace the "YYY" with
appropriate finish code
4MM HEX
WRENCH
Thank you for selecting American-Standard...the benchmark
of fine quality for over 100 years.
To ensure that your installation proceeds smoothly--please
read these instructions carefully before you begin.
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
CARE INSTRUCTIONS:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

American Standard T005.5XX User manual

Category
Sanitary ware
Type
User manual

American Standard T005.5XX is a pressure balancing bath and shower trim kit that offers precise temperature control and a comfortable showering experience. Its key features include:

  • Adjustable Hot Limit Stop: This safety feature allows you to set a maximum hot water temperature to prevent accidental scalding.

  • Easy Installation: The trim kit comes with clear instructions and all necessary mounting hardware for a hassle-free installation process.

  • Durable Construction: Made from high-quality materials, the trim kit ensures longevity and reliable performance.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI