Haier DSF80MB I E Operating instructions

Type
Operating instructions

This manual is also suitable for

Xiao Hai Feng
Haier Household Electrical Appliance Operating manual
DSF80B(E)
DSF80MB I (E)
DSF80MB II (E)
DSF65B(E) DSF65MB (E)
z Read this manual carefully before use
z Keep it in a safe place for reference
Dear Customer:
Thank you for selecting and using Haier water heater.
Haier products are of high quality and excellent performance. To facilitate smooth operation, please read this
manual carefully and follow the operation steps contained herein. It should be stored well after use. In case of any
problems in use, please contact your local after sales service departments.
Due to improvements in this product, the Haier water heater you have purchased may not be completely in
accordance with the diagrammatic presentations in the manual. Here, we apologize for it.
Safety warning expert
This safety sign is the special sign for “the Safety warning expert” used by the
Haier Water Heater Company. Our patent technologies are used inside to ensure
your safety when bathing; and at the same time monitor whether the ground
electrode in your house is charged. If this safety sign is on, it indicates that the
ground electrode in your house has been charged (the ground electrode has a bad
earth and charged). Then, you should stop using it immediately and cut off the
power switch; don’t touch the outside casing of any appliances and contact the after
sales service department or the Property Company immediately. A professional
electrician will carry out system inspection until the sign goes out. “Safety warning
expert” will become the electrical safeguard.
Logo of a Haier
Safety Water Heater
Contents
Product characteristics 1
Electrical schematic diagram 1-2
Packing list 2
Technical data
Appearance and components introduction 3
Technical parameters 3
Notice before use
Special notices 4
Installation guidelines
Installation method 4
Matters needing attention for installation 5
Usage guidelines
Components introduction 5
Usage 6
Matters needing attention for usage 6-7
Machine cleaning and maintenance 7
After service
Q/A 8
The appearance, color or pattern of the water heater can be seen by checking the product
Product characteristics·Electrical schematic diagram
Product characteristics
1. Safe and reliable:
Dry-heating prevention unit: under abnormal conditions, when the heating components of the water heater are at an
overly high temperature, the hand-reset temperature controller will cut off the power supply automatically and stop
heating.
Low water pressure and low flow protection: in case of shutoff of water control valve or abrupt cutoff of water supply
which results in the water flow lower than the minimum operating water flow, the water heater will stop working
automatically.
“Shockproof wall” patent design makes for safer use.
2. Advanced design, highly efficient and energy saving:
A water switch is installed to realize electrification by water supply, electrical outage by cutting off water, heating while
in use, high efficiency and energy saving.
Small volume, light weight, easy selection of installation position, and easy fastening.
Pollution-free, long service life, novel environmental-friendly green product.
3. Multipurpose:
Enclosed structure, able to connect with several outlets.
Electrical schematic diagram
1
L: Live wire (brown/red/black)
N
: Zero line (blue)
E: Ground electrode (yellowish green)
MT: Hand-reset temperature controller
EH: Heating pipe
K1, K2 and K3: switches
HL1, HL2 and HL3: Indicator lamps
BT: Constant temperature controller
N
ote: This is the line diagram of DSF65/80B (E)
Electrical schematic diagram·Packing list
Electrical schematic diagram
Packing list
Electric water
heater(SET)
Hosepipe and
shower
nozzle(SET)
Instruction packet High-grade
bracket
DSF80B (E)
DSF80MB I (E)
DSF80MB II (E)
DSF65B (E)
DSF65MB I (E)
1 1 1 2 1
2
L
:
Li
ve w
i
re
(brown/red/black)
N
: Zero line (blue)
E: Groun
d
electrode
(yellowish green)
MT: Hand-rese
t
temperature
controller
EH: Heating pipe
RT: Sensor
N
ote: This is the line diagram of DSF65/80MB I (E)
L: Live wire (brown/red/black)
N
: Zero line (blue)
E: Ground electrode (yellowish green)
MT: Hand-reset temperature controller
EH: Heating pipe
RT: Sensor
K1, K2 and K3: Switches
BT: Constant temperature controller
N
ote: This is the line diagram of DSF80MB II (E)
Product
model
QTY
Product
model
Appearance and components introduction·Technical parameters
Appearance and components introduction
Technical parameters
Model Rated power
supply
Rated
power
(W)
Water-
Proofing
grade
Net
weight
(Kg)
a1
(mm)
b1
(mm)
c1
(mm)
d1
(mm)
e1
(mm)
f1
(mm)
g1
(mm)
DSF80 B (E)
220V~/50Hz
2000w
4000w
6000w
8000w
IP*4 3 211 361 265 160 80 357 108
DSF80 MB I (E)
DSF80MB II (E)
DSF65B (E)
DSF65MB I (E)
1500w
3000w
5500w
7000w
Note: The allowable error range for parameters above (size and weight) is ±10%
Front view
Back view
Side view
A/B/C: Holes for hanging on the wall
D: Water flow regulating button
E: Power regulating button
3
Special notices·Installation method
Special notices
In order to guarantee the correct and safe application of the water heater, our company here notifies
customers that it is necessary to contact the professional service providers specified by Haier for home
service. In case of incorrect installation of the water heater, our company undertakes no responsibility.
z Ensure the water supply of the machine before powering it on; otherwise, it may cause faults in the machine
components. Ensure that air switch meets the national standard and is reliably grounded; it is forbidden to use
the water heater in case of unreliable grounding.
z When the electric water heater is seriously eroded by water, it can be cleaned up for reuse only if it is
inspected and accepted by our company’s technical personnel.
z Don’t place inflammable articles such as gasoline nearby the water heater; otherwise, accidents such as fire
hazards may take place.
Installation method
z It must be installed by professional installation personnel of our company’s after sales service department or
specified installation personnel.
z The water heater should be hung vertically on the wall and installed closely against the wall; it is forbidden
to be installed inversely or horizontally to ensure the sensitivity of the water flow switch.
Waterway installation:
z Before installation of the water heater, first carry out waterway installation, the installation method as
follows:
z First, determine the installation position of the water heater.
According to the installation dimensional drawing, drill three holes
with aФ4mm and the depth of 30mm in the wall; plug the plastic
expanding tubes into the holes A, B, and C (see the back view in
P3); then, screw bolts into the plastic expanding tubes in the upper
and right holes (don’t screw them in completely to facilitate
machine hanging); and fix these bolts firmly. Then, lift the water
heater and hang the back shell of the machine on the bolts; screw
another bolt into the plastic expanding pipe C and screw it firm. At
last, assemble the front shell of the machine and fix them with
bolts.
z There are the words “inlet” and “outlet” printed at the bottom of the water heater. First, install the filter
screen at the intake pipe; and then, connect the intake pipe with the outflow pipe and the shower nozzle; the
joints must be cushioned with seal rings to prevent water leakage; the installation refers to the drawing
above.
z Note: The hot water pipe should not be too long so as to avoid heat loss.
z When installing the water heater, there should be certain space set aside to facilitate future repair &
maintenance .
Circuit installation
z After the completion of waterway installation, test whether water can flow freely in the pipes; carry out
circuit installation if there is no water leakage.
Select proper air switch and power line according to the power of the water heater; the power line should be
connected with the water heater through the air switch. Be aware of the difference among the live wires
(brown/red/black), the zero line (blue) and the ground wire (yellowish green).
Air switch
Hot water outlet
Cold water inlet
4
Matters needing attention for installation·Components introduction
Matters needing attention for installation
z The electric water heater should be installed indoors where the ambient temperature is above 0; pipelines
should be arranged together. It is not suitable for the hot water outlets far away from the water terminals. If
the distance is over 8m, heat preservation treatment should be carried out on the pipeline to reduce heat loss.
z The electric water heater should be installed in places where it is easy for use and maintain and there are
buried pipes. In case of water leakage in the water tank or water pipes, no damage will be caused to the
nearby or lower story facilities. Besides, dont install the water heater in places where water sprays directly
and it is easily frozen.
z Due to its high power, before installation of the water heater, carefully inspect whether the electric
instruments, the wire diameter of power supply and fuse meet with the requirements of the rated current and
voltage of the water heater.
z Intake and outflow pipes must not be connected inversely (hot on the left and cold on the right).
z To ensure safety, air switch which measures up to the standard of the state should be used in the water heater,
and be grounded reliably. As the required current is very high, the power supply of the incoming line should
be connected directly to the air switch. Do not use the power plug.
z Check whether the live wire and the zero line are connected inversely with an electroprobe. Power-on the
water heater for heating until it is confirmed that the water tanks are fully filled with water, there is no water
leakage in the various joints and the power supply meets the requirements.
z Safety warning: in order to prevent the occurrence of accidents, accessories such as hosepipes and shower
nozzles provided by our company must be installed and must not be replaced or substituted; if the pipe
fittings are damaged, inform our companys repair & maintenance department to repair them and replace
them with accessories provided by our company. If accidents occur due to disobeying the matters and
attentions above, our company assumes no responsibility for the direct or indirect loss caused by the
accidents.
Components introduction
Note: Only the DSF80MB I (E), DSF65MB I (E) and DSF80MB II (E) models have the power panel and
display screen.
1. Constant temperature controller
2. Heating cup
3. Outflow pipe
4. Water flow regulating button
5. Intake pipe
6. Water flow switch
7. Power regulating button
8. Power panel
9. Display screen
10. Hand-reset temperature controller
11. Terminals
5
Usage·Matters needing attention for usage
Usage
z After the installation of the water heater for the first use, first carry out a water test; switch on power supply
until water flows continuously out of the shower nozzle or other water outlets.
z After switching on the power supply, regulate the water flow switch to get the appropriate water flow; then,
the machine will start up automatically; turn the power button to determine the gearshift required.
z After electrifying and heating for about 2s, hot water will flow out of the outlet (the practical outflow time
depends on the pipe length).
Temperature set
As to DSF80MB I (E), DSF65MB I (E) and DSF80MB II (E), after switching on the power supply and
turning on water flow switch to get the appropriate water flow, the screen will display the current water
temperature. For example, Fig. A shows the current water temperatures of DSF80MB I (E) and DSF65MB I
(E); Fig. B shows one of working interfaces of DSF80MB II (E). After switching on the power supply,
regulate the outflow temperature through the power regulating button and water flow regulating button.
Regulate the power according to the signs on the power button; in case of constant outflow, turn up the power
for heating, the outflow temperature rises correspondingly; on the contrary, the outflow temperature declines.
If stopping use of the water heater for long time, please shut off the air switch of the water heater. If required,
the customer can regulate the outflow temperature by regulating the water flow or power.
DSF80MB I (E)/DSF65MB I (E) display interface DSF80MB II (E) display interface
Fig. A Fig. B
Matters needing attention for usage
1. According to temperature change in different seasons, regulate and set heating levels flexibly. When the water
heater stops being used for a long term or has been repaired, first, discharge water for a while to wash out
sundries in the pipes before it is reused, to avoid blocking the water heater. Power-on the water heater for use
until water flows out of the shower nozzle or other outlets continuously.
2. In case of water interruption while in use, please close the air switch immediately.
3. This product is an enclosed water heater which can supply hot water for several outlets connected with pipes,
such as a bathroom (bathtub, washtub, and shower nozzle) and a kitchen.
4. In order to extend the service life of the water heater, after use, please close the intake valve; in case there is
no usage of the water heater for long period of time, please close the air switch.
Power
Working
6
Matters needing attention for usage·Machine cleaning and maintenance
Matters needing attention for usage
5. There must be an air switch installed in the circuit (depending on the power of the water heater). An earth
leakage protection switch must be installed in the customer's house, and the electric instruments should be
220V; for machines with the power of 6500W, 30A and copper core4 mm
2
; for machines with the
power of 8000W, 40A and copper core6 mm
2
; a water-proofing earth leakage protection switch with
the air switch 40A and copper core6 mm
2
; power supply copper core 6 mm
2
;
6. In case of ambient temperature lower than 0, ensure that water is not frozen in the water heater before
turning on the power supply of the water heater. If water is frozen in the water heater, the ice must be melted,
confirm that the water heater is not damaged with a water test before turning on the power supply for use.
7. The power line of the water heater shall be installed in a position where water can’t spray it; do not turn on a
power switch with wet hands. If the power line is damaged, it must be replaced by cables which meet with
the corresponding requirements of the national regulations.
8. When a fault of the water heater takes place, contact our company or the specified repair & maintenance
department in a timely manner to facilitate the immediate recovery.
9. If you live in a high-rise building and the water pressure exceeds the rated pressure of the product (such as:
larger than 0.6 MPa), it is recommended to contact our after sales service department to buy a pressure relief
valve so that the water heater can be reliably utilized.
Machine cleaning and maintenance
z External cleaning: cut off the power supply before cleaning the water heater. Use a small amount of a neutral
cleaning agent and a wet cloth and wipe the water heater gently (do not use gasoline or other solutions).
When cleaning is finished, towel off the water heater with a dry cloth until it is dry. Be aware to never use
cleaning agents with abrasives (such as toothpaste), acids, chemical solvents (such as alcohol) or metal
polishers to clean the water heater.
z Shower nozzle and filter screen cleaning: if the shower nozzle doesn’t spray fluently or there is a blockage,
an old toothbrush can be used to clear away sundries on the external surface of the shower nozzle and inlet
filter screen. Then, assemble the shower nozzle and the inlet filter screen. Check that the shower nozzle is
placed in the right position so as not to influence the spraying effect.
7
Q/A
Phenomenon Things to be confirmed Solutions
Water too hot 1. Water flow too low to water heater
or external tap water temperature
rising
2. Power too high
1. Turn up the inlet water
2. Turn down the power
Water temperature fluctuation Outlet water temperature higher than
58 ; the water heater is in the fixed
temperature control working state
As above
Water too cold 1. Water flow too high or power too
low
2. Water pressure too low so that the
water heater doesn’t start up
3. Voltage fluctuation
4. Lower than the requirements of the
product
1. Reduce the inlet water or
increase the power
2. Check whether the water
source is sufficient; if water
pressure needs to be
increased, temporarily close
other water valves in the
house or install an additional
pressure pump to increase
water pressure
3. Return to normal voltage
4. Contact the repair &
maintenance department
Without electricity 1. Water pressure too low so that the
water heater doesn’t start up
2. Power off
3. Parts and components don’t work or
are damaged
1. If the water pressure needs to
be increased, temporarily
close other water valves in
the house or install an
additional pressure pump to
increase water pressure
2. Have the circuit checked by
professional personnel
3. Contact with the repair &
maintenance department
When used, the power supply
air switch tripping takes place
1. Insufficient air switch capacity
2. Circuit fault of the water heater
1. Replace air switch
2. Have it checked by qualified
professional personnel
It doesn’t work in case of
water supply
1. Air switch tripping
2. The circuit is not connected
3. Over-temperature protection
Have the circuit checked and
repaired by professional
personnel
Displays E3 Sensor fault Have the circuit checked and
repaired by professional
personnel
8
Haier Group
Haier Water Heater Co., Ltd., Qingdao Economic and Technical Development Zone Version: 1
Address: Haier Industrial Park, Qingdao Economic and Technical Development Zone Special SN: 0040500
Website: http://www.haier.com VC
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

Haier DSF80MB I E Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI