Safety Precautions (please read before use)
Installation Instructions
Meaning of signs
Prohibition Warning
Warning
Warning
Warning
Warning
Grounding
It means that the actions
must be prohibited.
Once you find any abnormality or smell burnt odor,
please disconnect the water heater from power supply
immediately and contact Haier service center.
Be sure to use an independent power supply of
220V/50Hz.
Do not use a damaged power cord or power socket.
Please dust off the power plug and the socket in a
timely manner.
Please install the water heater on a solid and firm
wall.
Please check whether the ammeter and the diameter
of wire are in conformity with the water heater’s rated
current, and if necessary, ask a qualified technician
to check the circuitry.
It is prohibited to touch the plug with wet hands.
Please avoid the water heater and its plug, socket
and remote controller being wetted by water. If they
are inadvertently wetted, be sure to ask a qualified
technician authorized by our company to check and
confirm safe operation before using the water heater
again in order to avoid electric shock.
Do not install the water heater on the floor. Do not
install the water heater in a place without water
drainage facilities.
It is prohibited to put inflammable and explosive
substances near the water heater.
It is strictly prohibited to install or repair the water
heater before disconnecting it from power supply.
It is prohibited to repair, maintain, disassemble or
modify the water heater by an unprofessional
maintainer without authorization.
Be careful to avoid scald by hot water.
● It is prohibited to touch both the valve and pipe that
supply hot water.
● Be sure to feel and confirm water temperature to be
acceptable before shower.
Never use hot water made by the water heater as
drinking water or for other purposes.
Children must use the water heater under the
guidance of adults.
If the water heater will not be used for a long time,
please disconnect it from power supply and drain the
water tank of water heater by following the instruc-
tions in the section of “Cleaning and Maintenance”.
For the purpose of safety, the water heater should use
an independent and qualified socket (it is prohibited to
use a multifunctional socket) and should also be
reliably grounded. It is strictly prohibited to use the
water heater without reliable ground connection. In
addition, please check both live and neutral wires with
a test pencil for misconnection.
Due to relatively high power of the water heater, it is
recommended that a power socket matched with its
plug (16A) be used at the time of installation to ensure
its normal operation and domestic electrical safety.
It is strictly prohibited to install the water heater
outdoors.
It is strictly prohibited to install the water heater in a
place where ice may form, otherwise water tank and
water pipes may burst and thus cause scald and water
leakage.
In bitterly cold days, please take precautions to
prevent the water heater from damage due to freezing.
To avoid danger, the damaged power cord must be
replaced by the manufacturer, the repair center or an
authorized full-time maintainer.
domestic ground wire is charged; in this case, you should
immediately stop using the water heater, pull out its power
plug from the socket and contact Haier after-sales service
center or your property company to ask a qualified
electrician for system inspection until the sign goes out.
It is the special sign of “safety
early-warning expert” of Haier
Water Heater Company.
Adopting Haier’s patented
technology, the “safety
early-warning expert” ensures
your safe shower and
meanwhile always monitors
your domestic ground wire for
charge. When the sign lights
up, it means that your
It means that the actions
must be taken.
Caution
It means that the matters
must be paid attention to.
Warning! Improper operation may cause personal injury or death!
Caution! Improper operation may cause personal injury or property loss!
Safety sign of Haier
water heater
Warning
Warning
Warning
Prohibition
Prohibition
Prohibition
Prohibition
Prohibition
Prohibition
Prohibition
Prohibition
Caution
Caution
Warning
Components
Heating
keep
warm
H
Now
Preheat
Preheat
Mode choice
Night-elec
technology
Heat
preservation
M
Water heater
Remote
controller
Shower head
Hot water pipe
Cold water pipe
Water flow
sensor
Flow direction of cold water
Flow direction of hot water
Cold water
supply
Hot water supply
Remote
controller
holder
Cell replacement
Installation of
the relief valve
Installation method
Precautions for installation
Description of keys Description of icons
Cell scrapping
When the cell of remote controller is fully discharged,
open the cell cover with a one-yuan coin in the direction
as marked on the back of remote controller.
Install the relief valve (with the connection of G1/2)
onto the water inlet pipe in the direction of arrow
marked on the relief valve (the arrow points to the
water heater). When the water heater is turned on
to heat water, water in the water tank will expand,
so it is normal that several water drops may drip
from the pressure relief vent of relief valve to reduce
water pressure. Be sure to keep the pressure relief
vent to the atmosphere and unblocked.
The drain pipe with relief valve is installed as
follows: connect one end of the drain pipe to the
pressure relief vent of relief valve and the other end
to the sewage system in order to prevent the room
from being polluted by water drops at the time of
pressure relief. The drain pipe can be shortened or
extended as required. The drain pipe connecting to
the relief valve should keep downwards and inclined
in frostless environment.
Remove the button cell and replace it with a standard cell
of the same specification. Please make sure that the cell’s
positive pole is face up.
Fully discharged cells must not be placed in
high-temperature environment or throw into fire, otherwise
they may burst. Please dispose these cells in accordance
with relevant national regulations.
Remark: The keys on the remote controller are used in the same
manner as their corresponding keys on the control
panel.
Note: It is recommended to use the remote controller near
and perpendicular to the water heater.
Reinstall the cell cover in place.
Small handle
of relief valve
Pressure relief vent
(connect to the drain pipe)
To set hour
To set minute
To enter/exit the “
Preheat
” mode
To turn on/off the water heater
To enter/exit the “
Mode choice
” mode
● The water heater is designed for wall mounting.
● Before installing the water heater, make sure that the connecting wires on the back of water
heater are connected firmly. Preinstall the relief valve, flow sensor and one elbow, install the
elbow with relief valve and another elbow respectively onto water inlet/outlet pipes (the handle of
relief valve is installed at the end near the water outlet pipe as shown in Fig. 2) and connect the
connecting terminals of flow sensor to its interface. Afterwards, install the drain pipe with relief
valve and seal it with sealing tape to avoid water leakage. Please add washers up to the elbow’s
loose joint when installing an elbow.
● Determine the installation location of water heater, drill four holes of 12mm in diameter and
65mm in depth with a churn drill on the wall according to the dimensions as shown in Fig. 1,
insert expansion hooks/bolts into corresponding holes and fix them, lift up the water heater to
make its wall brackets be hooked to the hooks and bolts, install plain washers, connecting wires
on the back of water heater and nuts onto the bolts in turn (as shown in Fig. 3), and then tighten
the nuts and check the water heater for firmness. Afterwards, install the accessories such as
relief valve by following the instructions in the section of “Installation of the relief valve” (only for
reference at the time of installation). Please seal them with sealing tape to avoid water leakage.
● For easy installation and disassembly of the water heater, it is recommended that G1/2 loose
joint be installed respectively in proper position of water inlet/outlet pipes. Determine the location
where water is to be supplied to and then connect water inlet/outlet pipes and tap water pipe
respectively. Afterwards, fill the water tank and check for water leakage; in case of water leakage,
please reconnect the pipes.
Note: Be sure to always hold the water heater until its wall brackets are hooked to the hooks firmly,
otherwise it may drop and cause personal injury or properly loss.
● When installing the water heater, keep a certain space (at least 300mm) for easy repair and maintenance in the future. If the water heater is
built in a cabinet, the right panel should be removable for easy removal of the plastic cover at the time of repair.
● Make sure that tap water pressure is within the range of 0.05MPa~0.8MPa.
● The electric water heater should be installed in a room with ambient temperature above 0°C and the pipes should be in centralized layout. The
outlet of hot water should not be far away from the point of use. If the distance is more than 8m, please take proper measures for heat insulation
of hot water pipes to reduce heat loss.
● The wall on which the water heater is installed should be solid and firm and can bear four times the weight of water heater with its water tank full
of water. If the wall is not a bearing wall or is a hollow brick wall, be sure to take proper protective measures, e.g. addition of brackets, use of
through-wall screws and installation of back panel.
● The electric water heater should be installed in a location where is easy for use and repair and has a floor drain. In case of water leakage of
water tank or water pipe, the facilities around or under the water tank or water pipe should not be damaged. Avoid installing the water heater
above toilet bowl, bathtub, washbowl and door frame as possible to eliminate the feeling of oppression or unsafety.
● The power socket of water heater should be in a dry place without water spraying to ensure normal operation (it is recommended that the power
socket be equipped with waterproof case).
● Do not misconnect water inlet and outlet pipes. The relief valve should be installed in the specified position and its position must not be changed
without permission. Be sure to keep the pressure relief vent of relief valve to the atmosphere and unblocked.
● Check live and neutral wires with a test pencil for misconnection. Only after confirming that the water tank of water heater is full of water, no
water leakage occurs at each joint and power supply meets relevant requirements can you turn on the water heater to heat water.
To enter/exit the “
Night-electechnology
”
mode
It means that the water heater is heating
Time display
Icon of the “delay 1” mode
Icon of the “delay 2” mode
Icon of the “shower for a given number of persons” mode:
to indicate the number of persons to take a shower
When the “shower for one person” icon lights up, it means that the water
heater supplies hot water for one person to take a shower
When the “shower for two persons” icon lights up, it means that the water
heater supplies hot water for two persons to take a shower
When the “shower for three persons” icon lights up, it means that the water
heater supplies hot water for three persons to take a shower
It means that the water heater is in the
“low electricity price at night” mode
It means that the water heater is in the
“warm-keeping at medium temperature”
mode
It means that the water heater is in the
“3D heating” mode
Actual water temperature display
To enter/exit the “
Heat preservation
”
mode
Fig. 3
Fig. 2
Fig. 1
Volume