INSTRUCTIONS FOR USE
PrioCHECK™ FMD IPC Basic Kit
Basic equipment to run the IPC-products of Prionics
Pub. No. MAN0013931 Rev. C.0
Read the Safety Data Sheets (SDSs) and follow the handling instructions. Wear appropriate protective eyewear, clothing, and
gloves. Safety Data Sheets (SDSs) are available from thermofisher.com/support.
WARNING! POTENTIAL BIOHAZARD.
Read the biological hazard safety information at this product’s page at thermofisher.com. Wear
appropriate protective eyewear, clothing, and gloves.
Contents of the basic kit box
Store at room temperature
• Base Station with Pressure Reductor, Manometer and Bottle PP 2 L for
waste (Figure 1 (1)).
Note: The Base Station included with the PrioCHECK™ FMD IPC Basic Kit
may differ in appearance with the Base Station shown in Figure 1 (1).
• Manifold (Figure 1 (2), Figure 3).
• Vacuum pump, dry membrane type (Figure 1 (3)).
• Vacushield Filter (Figure 2).
• Three-way manual valves (Figure 3).
• Tubing with top vacuum tip (Figure 4).
• Micronic Decapper 1 and 8 (Figure 5).
Assembly instructions
1. Connect the tubing as shown in Figure 1 between the Pump (3) and the
manometer on the Base station (1).
2. Connect the on/off switch with the Vacushield Filter (Figure 2, pay
attention to “Fluid side”) and the vacuum inlet of the Waste Bottle.
3. Connect the Waste Inlet of the Waste Bottle with the Three-way Valve
and the Vacuum Manifold as shown in Figures 1 and 3.
4. The top vacuum tip (for emptying wells from the top, Figure 4) can be
attached to the three-way valve that connects the manifold to the Waste
Bottle (Figure 3).
5. Use the decappers from Figure 5 to decap the number of wells
necessary for the analysis of samples.
Appendix - References
Capozzo, Martínez, and Schielen (2010). Vaccine 28:6647–6652.
Figure 2. Vacushield Filter
Figure 3. Manifold connected to
three-way manual valve and tube
Figure 4. Tubing with top vacuum tips
Figure 5: Micronic Decapper 1 and 8
Customer and technical support
Technical support: visit thermofisher.com/askaquestion
Visit thermofisher.com/support for the latest in services and support,
including:
• Worldwide contact telephone numbers
• Order and web support
• User guides, manuals, and protocols
• Certificates of Analysis
• Safety Data Sheets (SDSs; also known as MSDSs)
NOTE: For SDSs for reagents and chemicals from other manufacturers,
contact the manufacturer.
Limited product warranty
Life Technologies Corporation and/or its affiliate(s) warrant their products
as set forth in the Life Technologies' General Terms and Conditions of Sale
found on Life Technologies' website at www.thermofisher.com
/us/en/home/global/terms-and-conditions.html. If you have any questions,
please contact Life Technologies at thermofisher.com/support.
Prionics Lelystad B.V. | Platinastraat 33 | 8211 AR Lelystad | The Netherlands
The information in this guide is subject to change without notice.
DISCLAIMER: TO THE EXTENT ALLOWED BY LAW, LIFE TECHNOLOGIES AND/OR ITS AFFILIATE(S)
WILL NOT BE LIABLE FOR SPECIAL, INCIDENTAL, INDIRECT, PUNITIVE, MULTIPLE, OR
CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING FROM THIS DOCUMENT,
INCLUDING YOUR USE OF IT.
Revision history of Pub. No. MAN0013931 (English)
C.0 25 November 2019
Added note regarding the appearance of the Base Station in
Figure 1 (1).
Updated the usage statement.
A.0 15 June 2017
New document. Converted the legacy document (MAN0013931
PrioCHECK Manual Basic Kit 7610820.doc) to the current document
template, with associated updates to the publication number, limited
license information, warranty, trademarks, and logos.
Important Licensing Information: These products may be covered by one or more Limited Use Label
Licenses. By use of these products, you accept the terms and conditions of all applicable Limited Use
Label Licenses.
©2019 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo
Fisher Scientific and its subsidiaries unless otherwise specified.