Series DPMA-4 Adjustable LCD Digital Panel Meters
Specifications - Installation and Operating Instructions
Bulletin G-63
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
Series DPMA-4 Adjustable LCD Digital Panel Meter offers a 3-1/2
digit display for easy viewing in a standard 1/8 DIN package. Unit
accepts 4 to 20 mA DC inputs with a wide bipolar span and zero
adjustment. Standard features include field selectable engineering units
and decimal point positions. Choose from red, amber, or green
segments for easy viewing at a distance. A 24 VDC power supply is
required for the operation of the backlight.
INSTALLATION
The Series DPMA-4 is designed to snap into a 3.62˝ (92 mm) W x 1.77˝
(45 mm) H panel cutout. No additional hardware is required.
WIRING
The unit is powered by a 4 to 20 mA loop and the screw terminal for
wiring is located on the back of the adder board marked with + SIG -. The
backlighting requires a 24 VDC power supply and should be connected
to terminals identified with +pwr-.
Note: If backlight supply is not loop supply, ground should be referenced
together.
SPECIFICATIONS
Input: 4 to 20 mA.
Input Impedance: 300Ω nominal.
Accuracy: ±(0.05% FS + 1 count).
Power Supply: Powered by control loop.
Backlight Power Supply: 24 VDC @ 35 mA typical.
Span and Zero: Adjustable (±1999 counts).
Display: 3-1/2 digits, 7 segments, 1˝ (25.4 mm) H.
Decimal Points: 3-position, user selectable.
Engineering Units: DPMA-XXX: °F, °C, %, PSI; DPMA-XXXP: V, A,
KW, PF.
Polarity: Automatic, “-” displayed.
Operating Temperature: 32 to 122°F (0 to 50°C).
Storage Temperature: -4 to 158°F (-20 to 70°C).
Mounting: Snap-in panel mount or clamp (gasket included).
Connection: Screw terminals.
Conversion Rate: 3 per second.
Warm-up: 10 minutes typical.
Weight: 4 oz (113.4 g).
Agency Approvals: RoHS.
SIG
-
+
PWR
J3
J2
J1
J7
J6
J5
J4
SPAN
ZERO
+
-
MA
TRANSDUCER
LOOP
POWER
SUPPLY
24V
BACKLIGHT
POWER
SUPPLY
TYPICAL LOOP CONNECTION
Figure 1
V
A
K
W
P
F
°F
°C
PSI
%
P Models
1
-59/64
[49]
1-59/64
[
49]
15/32
[12]
6
3/64
[25]
5/64
[
1.9]
1
3/64
[5]
1-1/8
[
28.5]
3
-25/32
[96]
1-57/64
[48]
3-15/32
[
88] REAR HOUSING
3
-5/8
[92]
1
-49/64
[45]
4-29/64
[113]
M
OUNTING BRACKET
OUTLINE REAR VIEW
PANEL CUTOUT
F
OR SNAP IN MOUNTING
(
R.010 MAX) 4 PLCS [.25 mm]
OPERATION
Selecting Engineering Units
Four sets of jumper pins are located in the back of the meter, between the
meter and the adder board. Move the jumper to fit over the appropriate pins
which correspond to the desired engineering units. See Figure 1 Example
shows °C turned on.
Selecting Decimal Point Position
Four decimal point positions are available on the digital process meter, J4-
J7. Move the jumper to correspond to the desired decimal point location.
See Figure 3.
Setting Min/Max Display Value J1, J2, J3 (See Figure 4 & 5):
If:
Min Display is ≤ 0 or
Min Display is > 0 and Max Display Min Display >
5,
Then:
J1, J2 & J3 should be all set to the top jumper. (See Figure 4).
If:
Min Display is > 0 and Max Display Min Display < 5,
Then:
J1, J2, J3 should be all set to the jumper. (See Figure 5).
MAINTENANCE/REPAIR
Upon final installation of the Series DPMA-4, no routine maintenance is
required. The Series DPMA-4 is not field serviceable and should be
returned if repair is needed. Field repair should not be attempted and may
void warranty.
WARRANTY/RETURN
Refer to “Terms and Conditions of Sale” in our catalog and on our website.
Contact customer service to receive a Return Goods Authorization number
before shipping the product back for repair. Be sure to include a brief
description of the problem plus any additional application notes.
DWYER INSTRUMENTS, INC.
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Fax: 219/872-9057 e-mail: [email protected]
©Copyright 2015 Dwyer Instruments, Inc. Printed in U.S.A. 7/15 FR# 443474-00 Rev. 3
Figure 2
Figure 3
Figure 4
%
P
SI
P
Models
P
F
K
W
P Models
V
A
°
F
°
C
(
13 PIN HEADER)
A
J3 J2
J1
B
Figure 5
A
J3 J2
J1
B
/