Haier Novel HSU12VHG-W User manual

Category
Mobile air conditioners
Type
User manual

This manual is also suitable for

WARNING
!
Ductless Split Air Conditioner
Indoor
HSU09VHG(DB)-W
HSU12VHG(DB)-W
HSU18VHG(DB)-W
HSU24VHG(DB)-W
Outdoor
HSU09VHG(DB)-G
HSU12VHG(DB)-G
HSU18VHG(DB)-G
HSU24VHG(DB)-G
User Manual
Design may vary by model number.
Thissystemshouldbeinstalledbyaqualied
HVAC professional. Do not attempt to install
the air conditioner by yourself because
incorrectinstallationmaycausere,water
leakage,personalinjuryordeath.
When abnormalities such as a burnt-smell are
found,immediatelypowerothemainswitch
and contact a licensed contractor.
Do not obstruct or cover the ventilation grille
ontheairconditioner.Donotputngersor
anyotherthingsintotheinlet/outletorswing
louver.
Donotallowchildrentoplaywiththeair
conditioner.Childrenshouldneverbeallowed
to sit on the outdoor unit
• Please read this manual before using the air conditioner.
• Keep this user manual for future reference.
Cautions and Warnings ................................. 1
Controller Features & Settings ...................... 2
Emergency Operation & Maintenance ........... 5
Troubleshooting ............................................ 6
Limited Warranty .......................................... 7
TABLE OF CONTENTS
PAGE 1
CONTROLLER FEATURES & SETTINGSPAGE 2
ENGLISH
3
8
6
17
4
15
16
12
10
9
7
5
14
2
13
11
1
1
Power Button
Press the ON/OFF button on the remote control to start
the unit.
2
QUIET Button
Thisfunctionmaybeusedwhensilenceisneededforrestor
reading. Press the QUIET
48,(7
button,theremotecontrol
willdisplaytheQUIET
iconandswitchtheunittothe
quiet function. Press the QUIET
48,(7
button again to cancel
this function.
Note:
Running the unit in QUIET mode for a long period of time
may cause the room temperature to not reach the set
temperature.Ifthisoccurs,cancelQUIETmodeandsetthe
fan speed to a higher setting.
3
COOL Button
InCOOLmode,theunitoperatesincooling.WhenFANis
settoAUTO,theairconditionerautomaticallyadjuststhe
fan speed according to room temperature. The
willbe
displayed during COOL mode.
4
HEAT Button
InHEATmode,warmairwillblowoutafterashortperiodof
the time due to cold-air prevention function. When FAN is
settoAUTO,theairconditionerautomaticallyadjuststhe
fan speed according to room temperature. The
willbe
displayed during HEAT mode.
5
DRY Button
DRYmodeisusedtoreducehumidity.InDRYmode,when
roomtemperaturebecomeslowerthantemp.setting+2°F,
unitwillrunintermittentlyatLOWspeedregardlessofFAN
setting. The
willbedisplayedduringDRYmode.
6
Temperature +/- Buttons
Temp+Everytimethebuttonispressed,thetemperature
setting increases.
Temp-Everytimethebuttonispressed,temperature
setting decreases.
Theoperatingtemperaturerangeis60°F-86°F(16°C-30°C).
7
AUTO Button
Underthemodeofautooperation,theairconditionerwill
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air condi-
tionerautomaticallyadjuststhefanspeedaccordingtoroom
temperature. The
willbedisplayedduringAUTOmode.
8
FAN Button
Fan speed selection
Press the FAN
)$1
button.Foreachpress,fanspeed
changesasfollows:
Remote control:
LOW
MED HI
AUTO
Display
circulated
Theairconditionerfanwillrunaccordingtothedisplayedfan
speed.
WhenFANissettoAUTO,theairconditionerautomatically
adjuststhefanspeedaccordingtoroomtemperature.
9
Louver SWING Button
Air Flow Direction Adjustment
1. Statusdisplayofairow
COOL/DRY:
Remote Controller
CONTROLLER FEATURES & SETTINGS PAGE 3
ENGLISH
HEAT:
2. Leftandrightairowadjustment(manual)
Manually move the vertical blade sets on the air conditioner
toadjustleftandrightdirectionreferringtothegurebelow.
'
Cautions:
• Turntheunitopriortoopeningthehorizontallouverand
adjustingtheverticalbladesbyhand.
• Whenhumiditylevelsarehigh,condensatewatermayoc-
curattheairoutletifallverticallouversareadjustedtoleft
or right.
• Itisadvisablenottokeepthehorizontallouverinthe
downwardpositionforanextendedperiodoftimeinCOOL
orDRYmode,otherwisecondensatewatermayformon
the louver.
Note:
When turning the unit on, the remote control will automatically
return the louver to the previous set swing position. When turn-
ing the unit o, the louver will rotate to the full open position
prior to closing.
10
Timer Button
On-OOperation
1. Start the unit and select the desired operating mode.
2. Press the TIMER
7,0(5
button to change to TIMER mode.
EverytimetheTIMERbuttonispressed,thedisplaychanges
asfollows:
Remote control display:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
TIMER OFF-ON
0.5h
0.5h 0.5h
0.5h
SelectthedesiredTIMERmode(TIMERONorTIMEROFFor
TIMERON-OFF).The“ON”or“OFF”iconwillash.
3. Press the
/ buttons to set the time.
- Pressing this button increases the time in 0.5 hour
incrementsbetweenhours0and12,and1hourincrements
fortimesbetweenhours12and24.
- Pressing this button decreases the time in 0.5 hour
incrementsbetweenhours0and12,and1hourincrements
fortimesbetweenhours12and24.
Theonorotimecanbeadjustedupto24hours.
4. Conrmtimersetting
Afteradjustingthetime,presstheCONFIRM/CANCEL
&21),50
&$1&(/
buttonandconrmthetimeONorOFFiconstopsashing
and remains displayed.
5. Cancel timer setting
Press the TIMER
7,0(5
button repeatedly until the time display
clears.
Note:
Holding the
/ buttondownwillrapidlycyclethe
time.Afterreplacingbatteriesorapowerfailureoccurs,the
timesettingwillneedtobereset.
According to the Time setting sequence of TIMER ON or
TIMEROFF,eitherStart-StoporStop-Startcanbeachieved.
12
EXTRA FUNCTION Button
Function:
A) Fan Mode - Is indicated by the
icon.Onlythefanwill
operateinthismode.Seesection8“FANButton”for
changing the fan settings.
B) Intelligent upward airow, C) Intelligent downward airow,
D) Reset intelligent airow position
1. Press the ON/OFF button on the remote control to turn
the unit on.
Select the desired operating mode.
2. Settingtheintelligentairowfunction
Press the EXTRA FUNCTION
(;75$
)81&7,21
button to enter ad-
ditional options. Press this button repeatedly to access
thelouversettings.Thelouvericonwillcyclethroughthe
followingthreesettings.
Healthy
airflow
upward
Healthy
airflow
downward
Present
position
Selectthedesiredposition,thenpresstheCONFIRM/
CANCEL
&21),50
&$1&(/
button to set the function.
3.Cancelingtheintelligentairowfunction
Press the EXTRA FUNCTION
(;75$
)81&7,21
button to enter addi-
tional options. Press this button repeatedly to access the
louversettings.Cyclethebuttontothelouvericon“pres-
ent”position,thenpresstheCONFIRM/CANCEL
&21),50
&$1&(/
button to cancel the function.
Notice:Donotrepositionthehorizontallouverbyhand.
This may cause the louver to run incorrectly and not
match the icon displayed on the remote control. If the
louverisnotrunningcorrectly,turntheunitoforone
minute,thenbackon,andadjustthelouversettingwith
the remote control.
CONTROLLER FEATURES & SETTINGSPAGE 4
ENGLISH
Note:
1. Aftersettingtheintelligentairowfunction,thelouver
positionisxed.
2. Incooling,itisbettertoselectthe
mode.
3. Inheating,itisbettertoselectthe
mode.
4. Incoolinganddrymodes,usingtheairconditionerfora
longperiodoftimeunderhighhumidityconditions,con-
densatewatermayformonthegrille/louver.
E) Right and left airow setting
Thiswilladjusttheleftandrightairowoftheunit.Press
theExtraFunction
(;75$
)81&7,21
button until
is displayed. This
willadjusttheleftandrightpositioningofthelouvers.
PresstheConrm/Cancel
&21),50
&$1&(/
button to apply the set-
ting.
F) A-B Yard -Thiswillallowyoutocontroltwoseperateunits
withasingleremotecontrol.
Note:thisfeaturewouldbesetupatthetimeofinstallation
by the contractor.
G) 50°F low temperature heating - Feature not available on
this series.
H) Sleep mode
PresstheExtraFunction
(;75$
)81&7,21
button to enter additional
options,cyclethebuttontodisplaythe
icon,the
iconwillash.PresstheConrm/Cancel
&21),50
&$1&(/
button to
enter the sleep function.
Sleep Operation Mode
1. SLEEPmodeduringCOOL,DRYmodes
OnehourafterSLEEPmodestarts,thetemperaturewill
rise2°Fabovesettemperature,afteranotherhour,the
temperaturerisesanadditional2°F.Theunitwillrunforan
additionalsixhours,thenturnso.Thenaltemperature
is4°Fhigherthantheinitialsettemperature.Usingthis
featurewillhelpwithachievingmaximumeciencyand
comfortfromyourunitwhileyousleep.
SLEEP operation starts SLEEP operation stops
Approx.6hrs
1 hr
Rises 2
O
F
Rises 2
O
F
Temp.setting
Unit stop
In COOL, DRY mode
1 hr
2. SLEEP mode during HEAT mode
OnehourafterSLEEPmodestarts,thetemperaturewill
decrease4°Fbelowsettemperature,afteranotherhour,
thetemperaturewilldecreaseanadditional4°F.Afteran
additionalthreehours,thetemperaturewillriseby2°F.
Theunitwillrunforanadditionalthreehours,thenturns
o.Thenaltemperatureis6°Flowerthantheinitialset
temperature.Usingthisfeaturewillhelpwithachieving
maximumeciencyandcomfortfromyourunitwhileyou
sleep.
SLEEP
operation starts
SLEEP
operation stops
1 hr
1 hr
3 hrs
3 hrs
Rises 3
O
F
Temp.setting
Unit stop
In HEAT mode
Decreases 4
O
F
Decreases 4
O
F
3. In AUTO mode
The unit operates in corresponding sleep mode adapted
to the automatically selected operation mode.
Note:
Whentheunitissettosleepmode,thefanspeedwillbe
settolowspeedandcannotbechanged.
Note:WhentheTIMERfunctionisset,thesleeping
function cannot be set. If the sleeping function has been
set,andtheusersetstheTIMERfunction,thesleeping
functionwillbecanceled,andtheunitwillbesettothe
timer function.
I) Electrical heating - Feature not available on this series.
J) Refresh air - Feature not available on this series.
K) Turbo
Usethisfunctionwhenrapidheatingorcoolingisneeded.
Press the EXTRA FUNCTION
(;75$
)81&7,21
button to enter
additionaloptions,cyclethebuttontodisplaythe
icon,the
iconwillash.PresstheCONFIRM/CANCEL
&21),50
&$1&(/
buttontoenterthepowerfunction.Tocancelthe
powerfunction,presstheEXTRAFUNCTION
(;75$
)81&7,21
button
againtoenteradditionaloptions,presstheCONFIRM/
CANCEL
&21),50
&$1&(/
buttonorselectadierentmodetocancel
thepowerfunction.
Note:
DuringPOWERoperation,inrapidHEATorCOOLmode,
the room may have uneven temperature distribution.
L) Fahrenheit/Celsius mode shift on unit and remote -
ToswitchbetweenFahrenheitandCelsiuspresstheEXTRA
FUNCTION
(;75$
)81&7,21
button until either Celsius or Fahrenheit is
displayed. Press the CONFIRM/CANCEL
&21),50
&$1&(/
button to apply
the change.
13
HEALTH Button
Feature not available on this series.
14
Conrm/CancelButton
Function: Setting and canceling timer and other functions.
15
LOCK Button
Used to lock buttons and LCD display
16
LIGHT Button
Turnsindoorunitdisplayonando
CONTROLLER FEATURES & SETTINGS PAGE 5
ENGLISH
Emergency Operation:
• Usethisoperationonlywhentheremotecontrolisdefec-
tive or lost.
• Whentheemergencyoperationswitchispressed,theunit
beepsonce,whichindicatesthestartofthisoperation.
• Whenthepowerswitchisturnedonforthersttimeand
emergencyoperationstarts,theunitwillrunautomatically
inthefollowingmodes:
• Duringemergencyoperation,itisnotpossibletochange
the settings of temperature and fan speed. It is also not
possible to operate in timer or dry modes.
Beep
emergency
operation switch
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 73
o
F
Below 73
o
F 73
o
F
79
o
F
No
AUTO
AUTO
COOL
HEAT
No
1. Remove the battery cover
2. Insert 2 AAA batteries as
illustrated noting battery polarity
3. Reinstall the battery cover
NOTE:
• The distance from the remote
control to the receiver should
belessthan23feetwithno
obstructions.
• Iftheremotecontroldisplayisweakortheoperating
distancehasdiminished,thebatteriesmayneedtobe
replaced.
• Remote control malfunctions can sometimes be corrected
byremovingthebatteriesfromtheremoteforafewmin-
utes and then reinstalling them.
• Remove the batteries from the remote control if the unit
willnotbeinuseforanextendedperiodoftime.Ifanyseg-
mentsofthedisplayremainactiveafterbatteryremoval,
press the reset button.
17
RESET Button
Iftheremotecontrolisnotfunctioningproperly,useapen
pointorsimilarobjecttodepressthisbuttontoresetthe
remote.
Do not block the air inlet
or outlet
Closedoorsandwindows
during operation
Wipe the air conditioner using a soft and
dry
cloth.Forseriousstains,useaneutral
detergent
dilutedwithwater
.
Wringthewater
outoftheclothbeforewipingdowntheunit.
Thenwipeothedetergentcompletely
.
During cooling operation
prevent direct sunlight
with curtains or blinds
1. Open the inlet grille by pulling
itupward
2. Removethelter.
Gently push up on the lter’s center
tab until it is released from the
stopper, and remove the lter
downward.
3. Cleanthelter.
Use a vacuum cleaner to remove
dust, or wash the lter with water.
After washing, dry the lter
completely.
4. Attachthelter
Attach the lter so that the “FRONT”
label is facing the front. Make sure
that the lter is securely attached
behind the holding tabs. If the lter is
not attached correctly the unit may
not achieve maximum eciency.
5. Close the inlet grille.
Once every
two months
EMERGENCY OPERATION & MAINTENANCE
Inserting the Batteries
Emergency Operation
Optimizing Performance
Cleaning the Air Filter
PAGE 6 TROUBLESHOOTING
ENGLISH
Normal
Performance
Inspection
Problem
The system
does not restart
immediately
Noise is heard
Odd smell
Mist or steam
areblowingout.
Indrymode,
fan speed can’t
be changed.
Poor cooling
•Whenunitisstopped,itwillnotrestartagainfor3minutestoprotectthesystem.
•Whenelectricityisdisconnectedandthenreconnected,theprotectioncircuitwillworkfor3minutesto
protect the air conditioner.
•Duringunitoperationorastop,aswishingorgurglingnoisemaybeheard.Therst2-3minutesafterthe
unithasstartediswhenthenoiseismostnoticeable.(Thisnoiseisgeneratedbyrefrigerantowinginthe
system.)
•Duringunitoperation,acrackingnoisemaybeheard.Thisnoiseisgeneratedbythecasingexpandingor
shrinking due to temperature changes.
•Iftheairowcreatingaloudnoiseduringunitoperation,theairltermaybetoodirty.
•Thesystemcirculatessmellsfromtheindoorairsuchasthesmelloffurniture,paint,and/orcigarettes.
•DuringCOOLorDRYoperation,indoorunitmayblowoutmist.Thisisduetothesuddencoolingofthe
indoor air.
•InDRYmode,whentheroomtemperaturebecomeslowerthanthesettemperatureby2°F,theunitwill
run intermittently at LOW speed regardless of FAN setting.
•Isthepowerpluginserted?
•Isthereapowerfailure?
•Isafuseblown?
•Istheairlterdirty?Normallyitshouldbecleanedevery2months.
•Isthereanythingblockingtheinletand/oroutlet?
•Isthetemperaturesetcorrectly?
•Arethereanydoorsorwindowsopen?
•Isthereanydirectsunlightthroughthewindowduringthecoolingoperation?(Usecurtains)
•Aretheretoomanyheatsourcesortoomanypeopleintheroomduringcoolingoperation?
Cause and Solutions
Conditions
to check for
Beforeaskingforservice,checkthefollowingrst:
LIMITED WARRANTY
5 YEAR LIMITED PARTS WARRANTY
Thiswarrantycoversalldefectsinworkmanshipormaterial
for the mechanical and electrical parts contained in this
product for a period of 5 years from the date of purchase. You
must keep and be able to provide your original sales receipt
as proof of the date of purchase.
7 YEAR COMPRESSOR WARRANTY
Thecompressorcontainedinthisproductiswarrantiedfora
period of 7 years from the date of purchase. You must keep
and be able to provide your original sales receipt as proof of
the date of purchase.
WHO IS COVERED
The original purchaser of this product.
HaierAmericawillreplaceanymechanicalorelectricalparts
orthatwhichprovesdefectiveinnormaloperationfora
period of 5 years. Compressor for 7 years.
HOW CAN YOU GET SERVICE
Contact your Installer.
All service must be performed by a licensed HVAC
techninican.
THIS WARRANTY DOES NOT COVER
1. Damages from improper installation.
2. Damages in shipping.
3. Defects other than manufacturing.
4. Damagesfrommisuse,abuse,accident,alteration,lack
of proper care and maintenance or incorrect electrical
voltage or current.
5. Damages from other than household use.
6. Damages from services performed by other than a
licencensed HVAC technician.
THIS LIMITED WARRANTY IS GIVEN IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
Theremedyprovidedinthiswarrantyisexclusiveandis
grantedinlieuofallotherremedies.Thiswarrantydoesnot
cover incidental or consequential damages. Some states
donotallowtheexclusionofincidentalorconsequential
damages,sothislimitationmaynotapplytoyou.Some
statesdonotallowlimitationsonhowlonganimplied
warrantylasts,sothislimitationmaynotapplytoyou.This
warrantygivesyouspeciclegalrightsandyoumayalsohave
otherrightswhichvaryfromstatetostate.
ThiswarrantycoversunitswithinthecontinentalUnited
States,CanadaandPuertoRico.
HaierAmerica,
Wayne,NJ07470
LIMITED WARRANTY
ENGLISH
PAGE 7
HaierAmerica,
Wayne,NJ07470
©2015HaierAmericaTrading,LLC.
Model#:HSU09VHG(DB)-W,HSU09VHG(DB)-G,
HSU12VHG(DB)-W,HSU12VHG(DB)-G,
HSU18VHG(DB)-W,HSU18VHG(DB)-G,
HSU24VHG(DB)-W,HSU24VHG(DB)-G
Issued Date: December 2014
www.Haier.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Haier Novel HSU12VHG-W User manual

Category
Mobile air conditioners
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI