Electrolux EPF09V1K8 User manual

Type
User manual
EN
IT
PL
User Manual
Manuale dell'utente
Instrukcja obsługi
2
24
46
EPF09V1K8
EPF12V1K8
EPF18V1K8
2 www.electrolux.com
1. SAFETY INSTRUCTIONS .................................................................................. 3
2. INDOOR UNIT PARTS AND MAJOR FUNCTIONS ........................................... 5
3. MANUAL OPERATIONS .................................................................................. 16
4. CARE AND MAINTENANCE ............................................................................ 17
5. TROUBLESHOOTING ..................................................................................... 19
6. EUROPEAN DISPOSAL GUIDELINES............................................................ 23
CONTENTS
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings
with it decades of professional experience and innovation. Ingenious and stylish, it
has been designed with you in mind. So whenever you use it, you can be safe in the
knowledge that you’ll get great results every time. Welcome to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com
Register your product for better service:
www.electrolux.com/productregistration
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CUSTOMER CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number
Warning / Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
3
ENGLISH
1. SAFETY INSTRUCTIONS
Before the installation and use of the
appliance, carefully read the supplied
instructions. The manufacturer is not
responsible if an incorrect installation
and use causes injuries and damages.
Always keep the instructions with the
appliance for future reference.
1.1 Children and vulnerable
people safety
WARNING!
Risk of suocation, injury
or permanent disability.
This appliance can be used by
children aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and
understand the hazards involved.
Children shall not play with the
appliance.
Cleaning and user maintenance
shall not be made by children without
supervision.
1.2 Installation and Use
WARNING!
Risk of suocation, injury
or permanent disability.
Contact an authorised installer for
installation of this unit.
Contact an authorised service
technician for repair or maintenance
of this unit.
The socket outlet required to
supply power must be connected
and commissioned by a licenced
contractor.
If the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent or similarly qualied
persons in order to avoid a hazard.
Installation work must be performed
in accordance with the national wiring
standards and the electricity suppliers
service rules by authorised personnel
only.
If the unit is to be moved to another
location or disposed of, only a suitably
qualied person is permitted to
undertake such work.
If you notice an unusal situation, such
as a burning smell, please switch o
the power to the air conditioner and
contact an Electrolux service agent. If
this abnormal status continues the air
conditioner may be damaged or even
cause electric shock or re.
Do not operate the air conditioner with
wet hands. This may cause electric
shock.
Do not damage or cut o the power
cord or other wires. If this occurs,
please have it repaired or replaced by
an accredited technician.
Do not connect this air conditioner to a
multi outlet power board.
Please switch o the power supply to
the air conditioner if it is not to be used
for an extended period. Otherwise, it
will accumulate dust and may cause
a re.
Before cleaning the air conditioner,
please disconnect the power supply
in order to eliminate the possibility of
electric shock.
The power supply should be
matched with the air conditioner. Air
conditioners provided with a supply
cord should be connected directly to
a power outlet with a suitable safety
switch. Air conditioners that are hard
wired must be connected to a suitable
safety circuit breaker.
Please ensure that the power supply
to the air conditioner is stable and
meets the requirements set out in the
installation manual.
Always ensure the product is installed
with appropriate earthing.
For safety, be sure to turn o the
circuit breaker before performing any
maintenance or cleaning or when the
product is not used for an extended
4 www.electrolux.com
You can also get this manual through your local distributor or by visiting our website.
Please nd the Electrolux web addresses to your local country from below table.
Country Website address Country Website address
Albania www.electrolux.al Netherlands www.electrolux.nl
Austria www.electrolux.at Norway www.electrolux.no
Belgium www.electrolux.be Poland www.electrolux.pl
Bulgaria www.electrolux.bg Portugal www.electrolux.pt
Croatia www.electrolux.hr Romania www.electrolux.ro
Czech Republik www.electrolux.cz Serbia www.electrolux.rs
Denmark www.electrolux.dk Slovakia www.electrolux.sk
Finland www.electrolux. Slovenia www.electrolux.sl
France www.electrolux.fr Spain www.electrolux.es
Germany www.electrolux.de Sweden www.electrolux.se
Greece www.electrolux.gr Switzerland www.electrolux.ch
Hungary www.electrolux.hu Turkey www.electrolux.com.tr
Italy www.electrolux.it UK & Ireland www.electrolux.co.uk
Luxembourg www.electrolux.lu
Please visit www.electrolux.com for more information
period of time. Accumulated dust may
cause re or electric shock.
Select the most appropriate
temperature. It can save electricity.
Do not keep windows and doors open
for a long time during operation. It will
result in insufcient performance.
Do not block the air inlet or outlet. It
will result in insufcient performance
and cause malfunctions.
Keep combustible materials away from
the units at least 1meter. It may cause
re.
Do not step on the top of the outdoor
unit or place heavy things on it. It may
cause damage or injury.
Do not attempt to repair the air
conditioner by yourself. Incorrect
repairs may cause electric shock
or re. Please contact your local
authorised service centre.
Do not insert your hands or objects
into the air inlet or outlet. It may cause
injury.
Do not expose animals or plants
directly to the airow.
Do not use the unit for any other
purpose, such as preserving food or
drying clothes.
Do not splash water on the air
conditioner. It may cause electric
shock or malfunction.
5
ENGLISH
2.1 Unit Parts
2.2 Operating Conditions
Use the system under the following temperatures for safe and eective operation. If
the air conditioner is used under dierent conditions, it may malfunction or become
less ecient.
2. INDOOR UNIT PARTS AND MAJOR FUNCTIONS
Display panel
Air outlet
Louver
Air inlet
COOL Mode HEAT mode DRY mode
Indoor
Temperature
17-32°C
(62-90°F)
0-30°C
(32-86°F)
17-32°C
(62-90°F)
Outdoor
Temperature
0-50°C
(32-122°F)
-15-24°C
(5-76°F)
0-50°C
(32-122°F)
-15-50°C
(5-122°F)
(low temperature
cooling models)
Fig 2.1
6 www.electrolux.com
2.3 Features
Default Setting
When the air conditioner restarts after a
power failure, it will default to the factory
settings (AUTO mode, AUTO fan, 24°C
(76°F)). This may cause inconsistencies
on the remote control and unit panel. Use
your remote control to update the status.
Auto-Restart (some models)
In case of power failure, the system will
immediately stop. When power returns,
the Operation light on the indoor unit will
ash. To restart the unit, press the ON/
OFF button on the remote control. If the
system has an auto restart function, the
unit will restart using the same settings.
Louver Angle Memory Function
(Optional)
Some models are designed with a louver
angle memory function. When the unit
restarts after a power failure, the angle of
the horizontal louvers will automatically
return to the previous position. The angle
of the horizontal louver should not be
set too small as condensation may form
and drip into the machine. To reset the
louver, press the manual button, which
will reset the horizontal louver settings.
Refrigerant Leak Detection
System (some models)
In the event of a refrigerant leak, the LCD
screen will display “EC” and the LED
indicator light will ash.
2.4 Energy Saving Tips
DO NOT set the unit to excessive
temperature levels.
While cooling, close the curtains to
avoid direct sunlight.
Doors and windows should be kept
closed to keep cool or warm air in the
room.
DO NOT place objects near the air
inlet and outlet of the unit. This will
reduce the eciency of the unit.
Set a timer and use the built-in SLEEP/
ECONOMY mode if applicable.
If you don’t plan to use the unit for a
long time, remove the batteries from
the remote control.
Clean the air lter every two weeks.
A dirty lter can reduce cooling or
heating eciency.
Adjust louvers properly and avoid
direct airow.
Closing curtains during heating also
helps keep the heat in
Doors and windows should be
kept closed
7
ENGLISH
2.5 Handling the remote
controller
8m
TEMP
AUT
O
C
OOL
D
RY
H
EAT
FAN
HIGH
MED
LOW
MODE
FAN SPE
ED
TIMER ON
SLEEP
ON/OFF
PLASMA
TIME
R OFF
AIR
D
IRECTION
RES
ET
LOCK
SET
TEMP
ERATU
RE(ć)
SENSOR
LED
DISP
LAY
T
URBO
VE
NT
Location of the remote
controller.
Keep the remote controller where
its signals can reach the receiver of
the indoor unit. (a distance of 8m is
allowed).
CAUTIONS
The air conditioner will not
operate if curtains, doors or
other materials block the signals
from the remote controller to the
indoor unit.
Prevent any liquid from falling
into the remote controller. Do
not expose the remote controller
to direct sunlight or heat.
If the infrared signal receiver
on the indoor unit is exposed
to direct sunlight, the air
conditioner may not function
properly. Use curtains to prevent
the sunlight from falling on the
receiver.
If other electrical appliances
react to the remote controller.
either move these appliances
or consult your local dealer.
2.6 Replacing batteries
.
The remote controller uses two alkaline
dry batteries (R03/LR03X2)
1. Slide the cover of the battery
compartment o according to the
arrow direction, then replace the old
batteries with new ones.
2. Insert the new batteries making sure
that the(+) and (-) of battery are
installed correctly.
3. Reattach the cover by sliding it back
into position.
NOTE: Do not use old batteries or
dierent type batteries or rechargeable
batteries, otherwise it may cause the
remote controller malfunction.
2.7 Remote Controller
Specication
Model R51I4/BGE, R51I4/
BGCE, R51I19/
BGE, R51I19/
BGCE RG51I47/
BG(C)E
Rated Voltage 3.0V(Dry batteries
R03/LR03×2)
Signal Receiving
Range
8m
Environment -5°C~60°C
8 www.electrolux.com
2.8 Performance Features
1. Operating Mode: COOL,
HEAT(Cooling only model without),
DRY, FAN and AUTO.
2. Timer Setting Function in 24 hours.
3. Indoor Setting Temperature Range:
17°C~30°C.
4. Full function of LCD (Liquid Crystal
Display)
2.9 Features of Remote
controller buttons
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
',5(&7,21
6:,1*
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
2SWLRQDOEXWWRQ
&/($1
$,5
785%2







6(/)
&/($1
)2//2:
0(
/('
',63/$<
1
TEMP Button : Push this button
to increase the indoor temperature
setting in 1°C increments to 30°C.
2
ON/OFF Button: Press this button to
start the indoor unit. Press again to
stop the unit.
3
FAN SPEED Button: Press the
button to select the Fan speed in
the sequence: AUTO, LOW, MED
and HIGH. Each time the button is
pressed, the fan speed selection is
shifted.
4
TIMER ON Button: Press this button
to activate the Auto-on time setting.
Each press will increase the time
setting in 30 minutes increments
if the setting time is lower than 10
hours. When the setting time reaches
10h, each press will increase the
time setting 1 hour in increments. To
cancel the Auto-on time setting, just
press the button until the time setting
is 0.0.
5
SLEEP Button: Active/Disable sleep
function. It can maintain the most
comfortable temperature and save
energy. For the detail, see “sleep
operation” in “USER S MANUAL”.
NOTE: While the unit is running under
SLEEP mode, it would be cancelled if
ON/OFF, FAN SPEED, SLEEP or MODE
button is pressed.
6
TIMER OFF Button: Press this
button to activate the Auto-o time
setting. Each press will increase the
time setting in 30 minutes increments
if the setting time is lower than 10
hours. When the setting time reaches
10h, each press will increase the
time setting 1 hour in increments. To
cancel the Auto-o time setting, just
press the button until the time setting
is 0.0.
7
LOCK Button: Press this recessed
button to lock all current settings, and
the remote controller will not accept
any operation except that of the
LOCK. Use the LOCK mode when
you want to prevent settings from
being changed accidentally. Press
the LOCK button again to cancel
the LOCK function. A lock symbol
will appear on the remote controller
display when the lock function is
activated.
8
TURBO Button: Push this button to
activate the Turbo function. Turbo
function enables the unit to reach
the preset temperature at cooling
or heating operation in the shortest
time(if the indoor unit does not
support this function, there is no
corresponding operation happened
when pressing this button.)
9
ENGLISH
9
LED DISPLAY Button: Press this
button to clear the display on the
indoor unit, press it again to light the
display.
10
RESET Button: Once the recessed
RESET button is pressed, all of the
current settings will be cancelled and
the controller will return to the initial
settings.
11
FOLLOW ME Button(on some
models): Push this button to initiate
the Follow Me feature, the remote
display is actual temperature at its
location. The remote control will
send this signal to the air conditioner
every 3 minutes interval until press
the Follow Me button again. The air
conditioner will beep to indicate the
Follow Me feature has ended if it
does not receive the signal during
any 7 minute interval.
12
SELF CLEAN(AUTO CLEAN)
Button: Press this button under
COOL or DRY mode, the self clean
function is activated. Under SELF
CLEAN mode, the air conditioner
will automatically clean and dry the
Evaporator and keep it as fresh for
the next operation.
13
CLEAN AIR Button(on some
models): When push this
button, the Ionizer/Plasma Dust
Collector(depending on models) is
energized and will help to remove
pollen and impurities from the air.
14
DIRECTION/SWING Button: Used
to stop or start horizontal louver
movement or set the desired up/
down air ow direction. The louver
changes 6 degree in angle for each
press. If keep pushing more than 2
seconds, the louver will swing up and
down automatically.
15
MODE Button: Each time the button
is pressed, the operation mode is
selected in the sequence of the
following:
AUTO
COOL
DRY
HEAT FAN
NOTE: Please do not select HEAT mode
if the machine you purchased is cooling
only type. Heat mode is not supported by
the cooling only appliance.
16
TEMP Button : Push this button
to increase the indoor temperature
setting in 1°C increments to 17°C.
Note:
Buttons design might be slightly
dierent from the actual one you
purchased depending on individual
models.
All the functions described are
accomplished by the indoor unit. If the
indoor unit has no this feature, there is
no corresponding operation happened
when press the relative button on the
remote controller.
10 www.electrolux.com
2.10 Indicators on display panel
Mode display
Displays the current selected mode.
Including AUTO, COOL, DRY, HEAT
(cooling & heating models only) and
FAN.
Transmission Indicator
This transmission indicator will light when
remote controller transmits signals to the
indoor unit.
Temp./Timer display
The temperature setting (from 17°C to
30°C) or timer setting (0~24h) will be
displayed. If FAN mode is selected, there
will be no display.
ON/OFF display
This indicator will be displayed when the
unit is operating.
Mode display (FAN mode)
Fan speed display
Displays the selected fan speed:
AUTO, HIGH, MED and LOW.
Nothing displays when the fan speed is
selected in AUTO speed. When AUTO or
DRY Mode is selected, there will be no
signals displayed.
FOLLOW ME display
When pressing FOLLOW ME button
in COOL or HEAT mode, the remote
sensing function is activated and this
indicator displays.
TIMER display
This display area shows the settings of
the TIMER. That is, if only the Auto-on
time function is set, it will display TIMER
ON. If only the Auto-o time function is
set, it will display TIMER OFF. If both
functions are set, it will display TIMER
ON OFF which indicates you have
chosen both the Auto-on time and Auto-
o time.
LOCK Indicator
LOCK display is displayed when pushing
the LOCK button. Push the LOCK button
to clear display.
SET TEMPERATURE
TIMER ON OFF
11
ENGLISH
2.11 Auto operation
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
When you set the air conditioner in
AUTO mode, it will automatically select
cooling, heating (Cooling & Heating
models only), or fan only operation
depending on what temperature you
have selected and the room temperature.
Once you select the operating mode,
the operating conditions are saved
in the unit’s microcomputer memory.
Thereafter, the air conditioner will start
operating under the same conditions
when you simply push the ON/OFF
button of the remote controller.
Start
Ensure the unit is plugged in and power
is available. The OPERATION indicator
on the display window of the indoor unit
illuminates.
1
Temperature button (TEMP)
Set the desired temperature.
Normally, set it between 21°C and
28°C.
2
Mode select button (MODE)
Press to select AUTO.
3
ON/OFF button
Press the ON/OFF button to start the
air conditioner.
Stop
ON/OFF button
Push this button again to stop the air
conditioner.
If the AUTO mode is uncomfortable,
you can select the desired conditions
manually.
When you select the AUTO mode, you
do not have to set the fan speed. The fan
speed will be automatically controlled.
2.12 COOL/HEAT/FAN
operation
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
Start
Ensure unit is plugged and power is
available.
1
Temperature button (TEMP)
Set the desired temperature, the
most comfortable temperature is
between 21°C and 28°C.
2
Fan speed button (FAN SPEED)
Press to select “AUTO”, “LOW”,
“MED” and “HIGH”.
3
Mode select button (MODE)
Press to select COOL, HEAT
(Cooling & Heating models only),
or FAN mode.
4
ON/OFF button
Press the ON/OFF button to start the
air conditioner. The OPERATION
12 www.electrolux.com
indicator on the display panel of the
indoor unit illuminates. The operating
mode is selected in accordance with
the room temperature and operation
starts after approximately 3 minutes
(If you select FAN mode, the unit will
start immediately).
Stop
ON/OFF button
Push this button again to stop the air
conditioner.
NOTE: The temperature cannot be
controlled under FAN only mode. While
in this mode, only steps 1, 3 and 4 may
be performed
2.13 DRY operation
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
Start
Ensure unit is plugged and power is
available. The OPERATION indicator on
the display panel of the indoor unit starts
ashing.
1
Temperature button (TEMP)
Push the “TEMP” button to set the
desired temperature.
2
Mode select button (MODE)
Press to select DRY.
3
ON/OFF button
Press the ON/OFF button to start
the air conditioner. No fan speed
indicator displays. The Indoor fan
speed will be automatically selected
LOW.
Stop
ON/OFF button
Push this button again to stop the air
conditioner
NOTE: The fan speed cannot be
adjusted when the unit is in AUTO
and DRY mode.
In DRY mode, due to the
temperature dierence between
the setting temperature and the
actual indoor temperature, the unit
will automatically operate in COOL
or FAN mode.
2.14 TIMER operation
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
1
To press the TIMER ON button can set
the auto-on time of the unit. To press the
TIMER OFF button can set the auto-o
time of the unit.
13
ENGLISH
To set the Auto-on time.
1. Press the TIMER ON button. The
remote controller shows TIMER ON,
the last Auto-on setting time and
the signal “h” will be shown on the
LCD display area. Now it is ready to
reset the Auto-on time to START the
operation.
2. Push the TIMER ON button again
to set desired Auto-on time. Each
time you press the button, the time
increases by half an hour between
0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER ON ,there will
be a onehalf second delay before the
remote controller transmits the signal
to the air conditioner. Then, after
approximately another 2 seconds,
the signal “h” will disappear and the
set temperature will re-appear on the
LCD display window.
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
1
To set the Auto-o time.
1. Press the TIMER OFF button. The
remote controller shows TIMER OFF,
the last Auto-o setting time and
the signal “h” will be shown on the
LCD display area. Now it is ready to
reset the Auto-o time to START the
operation.
2. Push the TIMER OFF button again
to set desired Auto-o time. Each
time you press the button, the time
increases by half an hour between
0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there
will be a onehalf second delay before
the remote controller transmits the
signal to the air conditioner. Then,
after approximately another 2
seconds, the signal “h” will disappear
and the set temperature will re-
appear on the LCD display window.
CAUTION
The eective operation time
set by the remote controller for
the timer function is limited to
the following settings: 0.5, 1.0,
1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5,
5.0, 5.5, 6.0, 6.5, 7.0, 7.5, 8.0,
8.5, 9.0, 9.5, 10, 11, 12, 13, 14,
15,16,17, 18, 19, 20, 21, 22, 23
and 24.
2.15 Example of timer setting
TIMER ON
(Auto-on Operation)
TIMER ON
h
The TIMER ON feature is useful when
you want the unit to turn on automatically
before you return home.
The air conditioner will automatically start
operating at the set time.
Start
Off
6 hours later
Set
Example:
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last
setting of starting operation time and
the signal “h” will show on the display
area.
14 www.electrolux.com
2. Press the TIMER ON button to
display “6.0h” on the TIMER ON
display of the remote controller.
3. Wait for about 3 seconds and the
digital display area will show the
temperature again. Now this function
is activated.
TIMER OFF
(Auto-o Operation)
TIMER OFF
h
The TIMER OFF feature is useful when
you want the unit to turn o automatically
after you go to bed. The air conditioner
will stop automatically at the set time.
The air conditioner will automatically start
operating at the set time.
Stop
On
Set 10 hours later
Example:
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the
last setting of stopping operation time
and the signal “h” will show on the
display area.
2. Press the TIMER OFF button to
display “10h” on the TIMER OFF
display of the remote controller.
3. Wait for about 3 seconds and the
digital display area will show the
temperature again. Now this function
is activated.
COMBINED TIMER
TIMER ON OFF
h
(Setting both ON and OFF timers
simultaneously)
TIMER OFF → TIMER ON
(On → Stop → Start operation)
This feature is useful when you want to
stop the air conditioner after you go to
bed, and start it again in the morning
when you wake up or when you return
home.
On
Stop
2 hours later
after setting
Set
Start
10 hours later
after setting
Example:
To stop the air conditioner 2 hours after
setting and start it again 10 hours after
setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again
to display 2.0h on the TIMER OFF
display.
3. Press the TIMER ON button.
4. Press the TIMER ON button again
to display 10h on the TIMER ON
display .
5. Wait for the remote control to
displaythe setting temperature.
TIMER ON → TIMER OFF
(O → Start → Stop operation)
TIMER ON OFF
h
This feature is useful when you want to
start the air conditioner before you wake
up and stop it after you leave the house.
Off
Stop
Start
2 hours later
after setting
5 hours late
r
after setting
Se
t
Example:
To start the air conditioner 2 hours after
setting, and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again
to display 2.0h on the TIMER ON
display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again
to display 5.0h on the TIMER OFF
display.
5. Wait for the remote control to display
the setting temperature.
15
ENGLISH
2.16 RESET and LOCK buttons
function
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
1
When you press the recessed LOCK
button, all current settings are locked
in and remote controller does not
accept any operation except that of
the LOCK.
Use the LOCK mode when you
want to prevent settings from being
changed accidentally. Press the
LOCK button again when you want to
cancel the LOCK mode.
A lock symbol will appear on the
bottom right hand side of the remote
controller display when the LOCK
function is activated.
2
When you press the recessed
RESET button, all current settings
are cancelled and return to original
factory settings.
2.17 DIRECTION/SWING
button function
1
$'-867
$872
&22/
'5<
+($7
)$1
+,*+
0('
/2:
02'(
)$163(('
7,0(521
6/((3
212))
7,0(52))
5(6(7/2&.
6(77(03(5$785(r&
)2//2:
0(
&/($1
$,5
785%2
',5(&7,21
6:,1*
/('
',63/$<
6(/)
&/($1
Use the DIRECTION/SWING button to
activate AUTO swing function and lock
louver in desired position.
1
When press this button once and
quickly, the air ow direction setting
feature of the louver is activated.
The moving angle of the louver is 6°
for each press. Keep pressing the
DIRECTION/SWING button to move
the louver to the desired position.
2
When press the button without
releasing for 2 more seconds, the
auto swing feature of the louver
is activated. The horizontal louver
would swing automatically. Press it
again to stop.
NOTE: When the louver swing or
move to a position which would
aect the cooling and heating
eect of the air conditioner, it would
automatically change the swing/ moving
direction(upward or downward).
16 www.electrolux.com
CAUTION
1. When replacing batteries,
do not use old batteries
or dierent type batteries.
Otherwise it may cause
the remote controller to
malfunction.
2. If you do not use the remote
controller for a few weeks or
more, remove the batteries.
Otherwise, battery leakage
may damage the remote
controller.
3. The average battery life during
normal use is approximately
half a year. Replace the
batteries when there is no
receiving beep from the indoor
unit or if the transmission
indicator on the remote
controller fails to light.
4. Be sure there are no barriers
between the remote controller
and the receiver of indoor unit
otherwise the air conditioner
will not work.
5. Keep the Remote Controller
away from all liquids.
6. Protect the Remote Controller
from high temperatures and
exposure to radiation.
7. Keep the indoor receiver out
of direct sunlight or the Air
Conditioner may malfunction.
8. Keep controller away from
EMI (Electro-Magnetic
Interference) supplied by
other household appliances.
3. MANUAL OPERATIONS
Infrared receiver
Manual button
Operation indicator
Timer indicator
PRE-DEF
(pre-heating/defrost)
indicator
LED display
Alarm indicator
This display panel on the indoor unit can
be used to operate the unit in case the
remote control has been misplaced or
is out of batteries.
Fig 3.1
Fig 3.2
17
ENGLISH
MANUAL button: This button selects
the mode in the following order: AUTO,
FORCED COOL, OFF.
FORCED COOL mode: In FORCED
COOL mode, the Operation light
ashes. The system will then turn to
AUTO after it has cooled with a high
wind speed for 30 minutes. The remote
control will be disabled during this
operation.
4.1 Safety Precautions
Contact an authorized service
technician for repair or maintenance.
Improper repair and maintenance may
cause water leakage, electrical shock,
or re, and may void your warranty.
DO NOT substitute a blown fuse with
a higher or lower amperage rating fuse,
as this may cause circuit damage or an
electrical re.
Make sure the drain hose is set up
according to the instructions. Failure to
do so could cause leakage and result
in personal property damage, re and
electric shock.
Make sure that all wires are connected
properly. Failure to connect wires
according to instructions can result
in electrical shock or re.
4.2 Unit Maintenance
BEFORE CLEANING
OR MAINTENANCE
Always turn o your air conditioning
system and disconnect the
power supply before cleaning or
maintenance.
DO NOT use chemicals or chemically
treated cloths to clean the unit.
DO NOT use benzene, paint thinner,
polishing powder or other solvents to
clean the unit. They can cause the
plastic surface to crack or deform.
DO NOT wash the unit under running
water. Doing so creates an electrical
hazard.
OFF mode: When the panel is turned
OFF, the unit turns o and the remote
control is re-enabled.
DO NOT use water hotter than 40°C
(104°F) to clean the front panel.
This can cause the panel to become
deformed or discolored.
Clean the unit using a damp, lint-free
cloth and neutral detergent. Dry the
unit with a dry, lint-free cloth.
4.3 How To Clean The Air Filter
The lter prevents dust and other
particles from entering the indoor unit.
Dust buildup can reduce the eciency
of the air conditioner. For optimum
eciency, clean the air lter every two
weeks or more frequently if you live in a
dusty area. Replace the lter with a new
one if it’s heavily clogged and cannot be
cleaned.
WARNING: DO NOT REMOVE
OR CLEAN THE FILTER BY
YOURSELF
Removing and cleaning the lter can be
dangerous. Removal and maintenance
must be performed by a certied
technician.
NOTE: In households with animals, you
will have toperiodically wipe down the
grille to prevent animal hair blocking
airow.
1. Unlock the grille by pushing the
two tabs towards the middle
simultaneously.
2. Unplug the display panel cable from
the control box on the main body.
4. CARE AND MAINTENANCE
18 www.electrolux.com
3UHVVWDEVWR
UHOHDVHJULOOH
)LJ
3. Detach the grille from the main unit
by holding the grille at a 45° angle,
lifting it up slightly and then pulling
the grille forward.
)LJ
4. Remove the air lter.
5. Clean the air lter by vacuuming the
surface or washing it in warm water
with mild detergent.
A. If using a vacuum cleaner, the
inlet side should face the vacuum.
)LJ
B. If using water, the inlet side
should face down and away
from the water stream.
)LJ
6. Rinse the lter with clean water and
allow it to air-dry. DO NOT let the lter
dry in direct sunlight.
7. Reinstall the lter.
8. Reinstall the front grille and
reconnect the display panel cable to
the control box on the main body.
4.4 Repairing Refrigerant Leaks
WARNING
If the refrigerant leaks, turn
o the air conditioner and any
combustible heating devices,
ventilate the room and call your
dealer immediately. Refrigerant
is both toxic and ammable. DO
NOT use the air conditioner until
the leak is repaired.
When the air conditioner is
installed in a small room,
measures must be taken
to prevent the refrigerant
concentration from exceeding
the safety limit in the event
of refrigerant leakage.
Concentrated refrigerant causes
a severe health and safety
threat.
Refrigerant Leak Detection System
(some models)
In the event of a refrigerant leak, the
LCD screen will display “EC” and the
LED indicator light will ash.
19
ENGLISH
4.5 Preparation For Periods
Of Non-Use
Maintenance after Extended Non-Use
1. Remove any obstacles blocking the
vents of both the indoor and outdoor
units.
2. Clean the air lter and the front grille
of the indoor unit. Reinstall the clean,
dry air lter in its original position.
3. Turn on the main power switch at
least 12 hours prior to operating the
unit.
Storing the Unit While Not In Use
1. Run the appliance on FAN mode for
12 hours in a warm room to dry it and
prevent mold.
2. Turn o the appliance and unplug it.
3. Clean the air lter according to the
instructions in the previous section.
Reinstall the clean, dry lter before
storing.
4. Remove the batteries from the
remote control.
5. TROUBLESHOOTING
CAUTIONS
If one of the following conditions
occurs, switch o the power supply
immediately and contact your
dealer for further assistance.
The operation light continues to
ash rapidly after the unit has been
restarted.
The remote control buttons do not
work.
The unit continually trips fuses or
circuit breakers.
A foreign object or water enters the
air conditioner.
Other abnormal situations.
5.1 Common Problems
The following symptoms are not a
malfunction and in most situations will
not require repairs.
Problem Possible Causes
Unit does not turn
on when pressing
ON/OFF button
The unit has a 3-minute protection feature that prevents the
unit from overloading. The unit cannot be restarted within three
minutes of being turned o.
Cooling and Heating Models: If the Operation light and PRE-
DEF (Pre-heating/Defrost) indicators are lit up, the outdoor
temperature is too cold and the unit’s anti-cold wind is activated
in order to defrost the unit.
In Cooling-only Models: If the “Fan Only” indicator is lit up,
the outdoor temperature is too cold and the unit’s anti-freeze
protection is activated in order to defrost the unit.
The unit changes
from COOL mode
to FAN mode
The unit changes its setting to prevent frost from forming on
the unit. Once the temperature increases, the unit will start
operating again.
The set temperature has been reached, at which point the unit
turns o the compressor. The unit will resume operating when
the temperature uctuates again.
The indoor unit
emits white mist
In humid regions, a large temperature dierence between the
room’s air and the conditioned air can cause white mist.
20 www.electrolux.com
5.2 Troubleshooting Tips
When troubles occur, please check the
following points before contacting a
repair company.
Problem Possible Causes
Both the indoor and
outdoor units emit
white mist
When the unit restarts in HEAT mode after defrosting, white
mist may be emitted due to moisture generated from the
defrosting process.
The indoor unit
makes noises
A squeaking sound is heard when the system is OFF or in
COOL mode. The noise is also heard when the drain pump
(optional) is in operation.
A squeaking sound may occur after running the unit in HEAT
mode due to expansion and contraction of the unit’s plastic
parts.
Both the indoor unit
and outdoor unit
make noises
A low hissing sound may occur during operation. This is normal
and is caused by refrigerant gas owing through both the
indoor and outdoor units.
A low hissing sound may be heard when the system starts, has
just stopped running or is defrosting. This noise is normal and
is caused by the refrigerant gas stopping or changing direction.
The outdoor unit
makes noises
The unit will make dierent sounds based on its current
operating mode.
Dust is emitted from
either the indoor or
outdoor unit
The unit may accumulate dust during extended periods of
non-use, which will be emitted when the unit is turned on. This
can be mitigated by covering the unit during long periods of
inactivity.
The unit emits
a bad odor
The unit may absorb odors from the environment (such as
furniture, cooking, cigarettes, etc.) which will be emitted during
operations.
The unit’s lters have become moldy and should be cleaned.
The fan of the
outdoor unit does
not operate
During operation, the fan speed is controlled to optimize
product operation.
Problem Possible Causes Solution
The unit is not
working
Power failure Wait for the power to be restored
The power switch is o Turn on the power
The fuse is burned out Replace the fuse
Remote control batteries are
dead
Replace the remote control
batteries
The unit’s 3-minute protection
has been activated
Wait three minutes after
restarting the unit
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68

Electrolux EPF09V1K8 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI